525W Open Frame Power Supply UL CE CCC G1008

Min.Order: 1
Product origin: Suzhou, Jiangsu, China
Infringement complaint: complaintComplaint
US$ 20

Description

525W Open Frame Power Supply UL CE CCC G1008

 

Description:G1008 525W Open Frame Power Supply
Output:54V 7.23A,12V11.25A,5V0.5A
Safety Approvals:UL CCC CE
Capacitor:Japanese Rubycon
Dimension: 190*136*34.5mm(L×W×H)
 

2.1 Input Specifications

ItemParameterTechnical RequirementUnitRemark
2.1.1Input115Vac 
230Vac 
2.1.2InputVoltageRange90 - 264Vac85Vac input can work
2.1.3Frequency47 - 63HzTyp.: 50Hz / 60Hz
2.1.4Inrush Current≤ 30AVin = 115Vac,cold start,25DegC.
≤ 60AVin = 230Vac,cold start,25DegC.
2.15Nominal Operating Current/A/
2.1.6Maximum Input Current≤ 10AVin = 90Vac,max load.
2.1.7Efficiency≥ 82% 115Vac input voltage,20% load.
≥ 85% 115Vac input voltage,50% load.
≥ 82% 115Vac input voltage,100% load.
≥ 82% 230Vac input voltage,20% load.
≥ 85% 230Vac input voltage,50% load.
≥ 82% 230Vac input voltage,100% load.
2.1.8PFC Factor≥ 0.95 100% load,25DegC.
≥ 0.90 50% load,25DegC.

2.2 Output Specifications

ItemParameterTechnical RequirementUnitRemark
2.2.1Rated Output Voltage+ 54Vdc 
+ 12Vdc 
+ 5Vdc 
2.2.2Output VoltageRange+52.38 - +55.62Vdc+ 54 output port
+11.64 - +12.36Vdc+ 12 output port
+4.75 - +5.25Vdc+ 5 output port
2.2.3Rated Output Current7.23A+ 54 output port
11.25A+ 12 output port
0.5A+ 5 output port
2.2.4Minimum Output Current0A 
2.2.5Load Regulation±5%  
2.2.6Line Regulation±2%  
2.2.7Turn-On Delay Time≤ 3SRated Input and Rated Load.
2.2.8Rise Time≤ 100    msThe output voltage from 10% to 90% of norminal input voltage and rated load.
2.2.9Hold-Up Time>= 16.7msV=100Vac, Rated Load.
2.2.10Output Ripple and Noise≤ 200(+54V)mVp-pApply a 0.1uF ceramic cap and 10uF E-Cap in parallel with output terminal for ripple and noise measurements, and set the oscilloscope bandwidth of 20MHz.
≤120(+12V)mVp-p
≤100(+5V)mVp-p
2.2.11Turn-On/Off Overshoot± 5% Vin = 90 - 264Vac,25DegC.
2.2.12Dynamic ResponseOvershoot Amplitude± 10%Load variation from 10%-100%-10%, frequency range should be 50Hz to 10KHz with duty cycle 50%,current slope is 2.5A/us;
0%-50%-0%, frequency range should be 50Hz to 10KHz with duty cycle 50%,,current slope is 2.5A/us;
± 5%25%-50%-25%, frequency rangeshould be 50Hz to 10KHz with duty cycle 50%,current slope is 2.5A/us;
50%-75%-50%, frequency rangeshould be 50Hz to 10KHz with duty cycle 50%,current slope is 2.5A/us.
2.2.13Transient Voltage+54V±3% 
+12V±3%
+5V±5%