2.1 Input Specifications | ||||||||
Item | Parameter | Technical Requirement | Unit | Remark | ||||
2.1.1 | Input | 115 | Vac | |||||
230 | Vac | |||||||
2.1.2 | InputVoltageRange | 90 - 264 | Vac | 85Vac input can work | ||||
2.1.3 | Frequency | 47 - 63 | Hz | Typ.: 50Hz / 60Hz | ||||
2.1.4 | Inrush Current | ≤ 30 | A | Vin = 115Vac,cold start,25DegC. | ||||
≤ 60 | A | Vin = 230Vac,cold start,25DegC. | ||||||
2.15 | Nominal Operating Current | / | A | / | ||||
2.1.6 | Maximum Input Current | ≤ 10 | A | Vin = 90Vac,max load. | ||||
2.1.7 | Efficiency | ≥ 82% | 115Vac input voltage,20% load. | |||||
≥ 85% | 115Vac input voltage,50% load. | |||||||
≥ 82% | 115Vac input voltage,100% load. | |||||||
≥ 82% | 230Vac input voltage,20% load. | |||||||
≥ 85% | 230Vac input voltage,50% load. | |||||||
≥ 82% | 230Vac input voltage,100% load. | |||||||
2.1.8 | PFC Factor | ≥ 0.95 | 100% load,25DegC. | |||||
≥ 0.90 | 50% load,25DegC. | |||||||
2.2 Output Specifications | ||||||||
Item | Parameter | Technical Requirement | Unit | Remark | ||||
2.2.1 | Rated Output Voltage | + 54 | Vdc | |||||
+ 12 | Vdc | |||||||
+ 5 | Vdc | |||||||
2.2.2 | Output VoltageRange | +52.38 - +55.62 | Vdc | + 54 output port | ||||
+11.64 - +12.36 | Vdc | + 12 output port | ||||||
+4.75 - +5.25 | Vdc | + 5 output port | ||||||
2.2.3 | Rated Output Current | 7.23 | A | + 54 output port | ||||
11.25 | A | + 12 output port | ||||||
0.5 | A | + 5 output port | ||||||
2.2.4 | Minimum Output Current | 0 | A | |||||
2.2.5 | Load Regulation | ±5% | ||||||
2.2.6 | Line Regulation | ±2% | ||||||
2.2.7 | Turn-On Delay Time | ≤ 3 | S | Rated Input and Rated Load. | ||||
2.2.8 | Rise Time | ≤ 100 | ms | The output voltage from 10% to 90% of norminal input voltage and rated load. | ||||
2.2.9 | Hold-Up Time | >= 16.7 | ms | V=100Vac, Rated Load. | ||||
2.2.10 | Output Ripple and Noise | ≤ 200(+54V) | mVp-p | Apply a 0.1uF ceramic cap and 10uF E-Cap in parallel with output terminal for ripple and noise measurements, and set the oscilloscope bandwidth of 20MHz. | ||||
≤120(+12V) | mVp-p | |||||||
≤100(+5V) | mVp-p | |||||||
2.2.11 | Turn-On/Off Overshoot | ± 5% | Vin = 90 - 264Vac,25DegC. | |||||
2.2.12 | Dynamic Response | Overshoot Amplitude | ± 10% | Load variation from 10%-100%-10%, frequency range should be 50Hz to 10KHz with duty cycle 50%,current slope is 2.5A/us; | ||||
0%-50%-0%, frequency range should be 50Hz to 10KHz with duty cycle 50%,,current slope is 2.5A/us; | ||||||||
± 5% | 25%-50%-25%, frequency rangeshould be 50Hz to 10KHz with duty cycle 50%,current slope is 2.5A/us; | |||||||
50%-75%-50%, frequency rangeshould be 50Hz to 10KHz with duty cycle 50%,current slope is 2.5A/us. | ||||||||
2.2.13 | Transient Voltage | +54V | ±3% | |||||
+12V | ±3% | |||||||
+5V | ±5% |