Capacity(t) | 1~4.7 | 10~22 | 33 | 47 | 68 | 100 | 150 | 220 | 330 | 470 |
D | 60 | 75 | 95 | 130 | 130 | 150 | 150 | 225 | 225 | 270 |
D1 | 53 | 75 | 95 | 130 | 130 | 150 | 150 | 225 | 225 | 270 |
D2 | 20 | 30 | 40 | 60 | 60 | 70 | 70 | 100 | 100 | 120 |
H1 | 7.5 | 6.5 | 10 | 14 | 14 | 16 | 16 | 24 | 24 | 28 |
H2 | 43 | 50 | 65 | 75 | 85 | 90 | 100 | 130 | 145 | 170 |
H3 | 7 | 7 | 7 | 7 | 7 | 7 | 10 | 10 | 10 |
Specification | ||||
Model | HMD2004RTN/TY2004RTN | |||
Accuracy class | %F.S | 0.02 | 0.03 | 0.05 |
Output sensitivity | mV/V | 2.85±0.25% | ||
Nonlinearity | %F.S | ±0.02 | ±0.03 | ±0.05 |
Repeatability | %F.S | 0.02 | 0.02 | 0.03 |
Hysteresis | %F.S | 0.02 | 0.03 | 0.05 |
Creep (30 min) | %F.S | ±0.02 | ±0.03 | ±0.05 |
Temperature effect on zero | %F.S/10ºC | ≤0.002 | ≤0.003 | ≤0.005 |
Temperature effect on output | %F.S/10ºC | ≤0.002 | ≤0.003 | ≤0.005 |
Zero output | %F.S | ±1 | ±1 | ±2 |
Input resistance | Ω | 4480±50 | ||
Output resistance | Ω | 4010±10 | ||
Insulation resistance | MΩ | ≥5000 | ≥2000 | |
Excitation voltage | V(DC/AC) | 5~12V | ||
Operating temperature range | ºC | -30 ~ +80 | ||
Overload capacity | %F.S | 150 | ||
Capacity | 1~470t | |||
Protection class | IP67 |
Company details
With 20 years' experiences,we can design and manufacture hundreds of different kinds of load cells:analogy load cell, high temperature load cell, digital load cells and so on. Most of load cells have patents.We guarantee the high quality with competitive price.