Model | ZR150S |
Operating Voltage | DC3V (CR123A) |
Battery Capacity | 1600mAh |
Average Quiescent Current | <9uA |
Alarming Mode | Sound + light |
Alarming Sound Level | ≥85dB (at 3 m) |
Operating Humidity | ≤95%RH (non-condensation) |
Battery Life | 10 years (typical value) |
Operating Temperature | -10ºC~55ºC |
Installation | Ceiling-mounted (screwing or 3 M glue) |
Size (L*W*H) | 76mm*76mm*28.5mm |
Standard | EN 14604:2005+AC:2008 |
The ZR150S household standalone photoelectric smoke alarm (alarm) detects fire by sensing smoke. When smoke in the room reaches a certain concentration, the alarm will send out sound and light warning alarm. This alarm is applicable for residential houses.
Standard implemented: EN 14604:2005/AC:2008
·Place the mounting plate on the desired installation location and mark where the holes should be drilled.
·Drill two holes with a diameter of 4 millimetres. (The distance between them is 42 millimetres)
·Push the plastic plugs into the holes.
·Insert the screws into the mounting plate, and tighten them firmly into the plugs.
·Fasten the smoke alarm on the mounting plate by twisting clockwise.
·Fasten the smoke alarm when the holes on the mounting plate and smoke alarm are aligned.
·Press the test button to check whether the smoke alarm operation normally, the smoke alarm is abnormal and can
not be used if no sound.
plastic plugs size:M4*20
Screw size:M2.6*16