Three Phase Pec-H3c Measurement Instrument Tester for LV Measurement Instruments

Min.Order: 1
Product origin: Wenzhou, Zhejiang, China
Infringement complaint: complaintComplaint
US$ 2826

Description
The single-phase energy meter calibrator is a set of 0.1-magnitude high precision field calibration instrument, but it is qualitatively different from the single-phase field calibration made of energy meter chip.
Where there is no load on the spot, its current output can be used as a virtual load, which is greatly convenient for field testing of single-phase energy meter.


 
ITEMUnitQuantity
PEC-H3C Comprehensive metering testerSET1
20A clamp meter(Three Phase)PCS3
optical head DF303LPCS1
Calibrator voltage test line(Red black withφ3.8 Plug/yellow green withφ4 Plug)2.1MM2*3MPCS1
Special charging line 2 metersPCS1
Single table pulse linePCS1
PEC Serial communication linePCS1
Instrument package 360*160*200MMPCS1
Background management softwarePCS1
PEC-H3C instructionsPCS1
Half closed jaw clamp 5MM(10pcs)SET1
List of parts(50Aclamp meter)
General 
Power supplyAC 57.7~400V
Power consumptionAbout 10VA
Ambient temperature'-20ºC--+40ºC (accuracy assured)
Relative humidity (not condensing)40%-95% (not condensing)
Dimension(D×W×H,mm)249×154×58
Weight1.2Kg
Warm-up time< 3 minutes
Battery endurance4 hours
LCD color display5.7", 320×240 TFT
Communication portRS 232
Safety
Declaration of conformityCE conformed
Operation reference
Measuring range 
VoltageAC 30~440V
Current20A (30mA~20A)
(clamp-on CT's)100A (100mA~100A)
 500A (100mA~500A)
 1000A (100mA~1000A)
Frequency45~55Hz
Phase-180 º ~+180º
Current input ( via clamp-on CT's input)20A: ±0.3%, ±0.5%
100A, 500A, 1000A: ±0.5%
Constant of pulse20A: FL=3.6×104P/KWh
Others: FL=36000×5/rated current (P/KWh)
Intrinsic error
Active power±0.2%, ±0.5%
Power±0.2%, ±0.5%
Voltage±0.2%, ±0.5%
Current±0.2%, ±0.5%
Frequency±0.05Hz
Phase±10%
Accuracy of measurement±0.2%, ±0.5%
  
General 
 
Power supplyAC 57.7~400V
Power consumptionAbout 10VA
Ambient temperature-20ºC--+40ºC (accuracy assured)
Relative humidity (not condensing)40%-95% (not condensing)
Dimension(D×W×H,mm)249×154×58
Weight1.2Kg
Warm-up time< 3 minutes
Battery endurance4 hours
LCD color display5.7", 320×240 TFT
Communication portRS 232
Safety
Declaration of conformityCE conformed
Operation reference
Measuring range 
VoltageAC 30~440V
Current20A (30mA~20A)
(clamp-on CT's)100A (100mA~100A)
 500A (100mA~500A)
 1000A (100mA~1000A)
Frequency45~55Hz
Phase-180 º ~+180º
Current input ( via clamp-on CT's input)20A: ±0.3%, ±0.5%
100A, 500A, 1000A: ±0.5%
Constant of pulse20A: FL=3.6×104P/KWh
Others: FL=36000×5/rated current (P/KWh)
Intrinsic error
Active power±0.2%, ±0.5%
Power±0.2%, ±0.5%
Voltage±0.2%, ±0.5%
Current±0.2%, ±0.5%
Frequency±0.05Hz
Phase±10%
Accuracy of measurement±0.2%, ±0.5%

Note:For more information,just contact us,we will provide you with more detailed operation procedures~
 
Product Tag:
Related categories: