Hikelok Twin Ferrule Tube Fitting Compression Fittings Stainless Steel 1/16 1/2 in. Od Plug

Min.Order: 1
Product origin: Chengdu, Sichuan, China
Infringement complaint: complaintComplaint
US$ 3 ~ 70

Description
Product NameHikelok® Twin Ferrule Tube Fittings Plug
Working Pressure3900 to 11000 psi
Connector TypeFNPT NPT NPTO FBT MBT MNTO FBP PMBP MBS MBP FMS MS BPMS BSMS OMS FST MST BPST BSST OST PPT PMS PST AN FSW FBW MSW MBW
Connector Size1/16 to 2 in and 2 to 50 mm
NoticeIf you do not find suitable specifications, please send the inquiry to me directly, and I will send catalog and quote for you.


Features:

* Twin ferrule fittings provide metal-to-metal seal connections, non-elastomeric seals for leak-free connections
* Hikelok twin ferrule fittings are designed to have a maximum allowable working pressure that is higher than that of any tubing
* Industry standard design for all instrumentation grade tubing
* Stainless steel tube harderness: the hardness of the tube shall be not greater than 85 HRB
* Available in sizes from 1/16 to 2in and 2 mm to 50 mm
* Hikelok fittings materials include 316 stainless steel, steel, brass, aluminum, nickel-copper, Hastelloy C, 6Mo, Incoloy 625 and 825
* Hikelok special treated back ferrule is to provide secure
* Silver coated threads to reduce galling
* Leak-proof joints capable of satisfying high pressure vacuum and vibration applications

Performance

* Hydraulic proof pressure test (1 .5 times the maximum permissible working pressure): no leakage
* Dismantling and reassembly test (dismantle 10 times): no leakage
* Minimum hydrostatic pressure test (4 times the maximum permissible ambient pressure rating): no leakage
* Vacuum test (1 x 10-* mbar or greater): the leak rate less than 1 x 10-*
* Maximum static gas pressure test (with nitrogen gas to 150% of pressure rating): no visible bubbles
* Hydraulic impulse and vibration test (the pressure impulses at between 0.5 Hz and 1.7 Hz and the vibration at between
  23 Hz and 47 Hz): no leakage
* Thermal cycle test (ambient to +80 "C and then to -25 "C with a hydrostatic pressure): no evidence of leakage
* Pneumatic pressure vibration test (The frequency of vibration shall be set at 45 Hz and complete 20 x 10* cycles): without failure
* Fire test (in accordance with BS ISO 19921): no leakage
* Corrosion resistance test (the duration of exposure at least 168 h): no visible evidence of corrosion
* Deep water submersion test (equivalent to 3048 m of sea water): no helium detected