Openning Ultrasonic Sensor for Phonics Test Equipment

Min.Order: 50
Product origin: Shenzhen, Guangdong, China
Infringement complaint: complaintComplaint
US$ 0.8 ~ 1

Description
1.Part Description
1Openning ultrasonic sensor
2Optional housing material for both alnuminum or plastic
3Optional for TX or RX
4Pins to solder on PCBA
 
2.Electronic specification & physical character
ItemDescriptionStandard or testing result ItemDescriptionStandard or testing result
1Part NumberKT58-T10118Max. Input Voltage(Vp -p)100V
2FunctionalRX or TX 9Sensor colourNatural aluminum or black plastic or customization
3Center frequency(KHz)58±110Dimension (mm)Optional for diameter
10 
4Sound Pressure Level
10Vrms/30cm(dB)
RX  none / TX ≥10811Weight (g)Min. 0.5 to Max.0.7
5Sensitivity (db)RX ≥-68  / TX none12Operation temperature-10ºC~+60ºC
6Capacitance(PF)2200±25%13Stock temperature-40ºC~+85ºC
7Beam angle75±10 
 
3.Dimension and detective diagram
 
4. Environmental test
No.Test itemsTest conditionStandard
1 144 hours at + 85 ºCAfter the test and place in + 25 ºC (room temp) for 24 hours, the sensitivity and residual vibration change shall not exceed 30% compared with the initial value 
2Low temp storage test144 hours at - 40 ºC
3High temp and high humidity storage test144 hours at + 65 ºC and 85 ± 5% RH
4Thermal shock testParallel 3.9k Ω resistor at both ends of the probe, keep the temp at - 40 ± 5 ºC for 0.5h, and increase the temp to 85 ± 5 ºC within 5 minutes and keep for 0.5h.100 cycles.After the test and place in + 25 ºC (room temp) for 24 hours, the sensitivity and residual vibration change shall not exceed 30% compared with the initial value 
5Vibration testProducts bear the vibration with frequency 10-55hz, amplitude 1.5mm,and sweep rate 1oct / min, from X, Y and Z directions for each 2 hours respectivelyAfter the test and place in + 25 ºC (room temp) for 4 hours, the sensitivity and residual vibration change shall not exceed 30% compared with the initial value 
6Monomer drop test15 free fall tests carried out from 100 ± 10cm height to 50mm thick wooden floorAfter the test and place in + 25 ºC (room temp) for 4 hours, the sensitivity and residual vibration change shall not exceed 30% compared with the initial value
7Strength test of outletApply 9.8N pulling force between shell and wire for 30 secondsThe wire is not loose or falling off, the product function is normal, and the wire is not damaged
8Protection levelPlace the probe in 15cm deep water and soak for 24 hoursTake out the capasual from the water and install it on the test board to measure the distance. The probe works normally without long sound.
9High and low temp characteristic testKeep the temp at -40ºC for 2h,increase to 25ºC and keep for 2h,increase to 85ºC and keep for 2h. After the test and place in + 25 ºC (room temp) for 2 hours, the sensitivity and residual vibration change shall not exceed 30% compared with the initial value
10High and low temp working testUnder high temp 85 ºC, low temp - 40 ºC, working voltage 140 Vp-p, pulse number 20, continuous working 48 hoursProbe works normally (sensitivity and residual vibration are within normal range)
 
5.Test conditions and instruments
No.Test itemTest instruments/methodTest condition
1resonant frequencyImpedance analyzerambient temperature 25 ± 5 ºC
2static capacitanceLCR bridge measuring instrumentambient temperature 25 ± 5 ºC
3residual oscillationKT test equipmentambient temperature 25 ± 5 ºC
4sensitivityKT test equipment0.8m at room temperature, target Φ 75mm PVC pipe
5Angle (X & Y axis)KT test board, as per Fig.1Under normal room temperature, the probe is 500mm from the ground, 500mm from the object to be detected, and the object to be detected is Φ 75mm PVC pipe, 1000mm high. The test environment: 2 meters in front and 1.5m in the left and right without obstacles
6Maximum allowable input voltageKT test board and Oscilloscope140vp-p, pulse width 0.5ms,
intermittent: 10ms
7Mean time between failuresaging test rackTest temp 25±5ºC
 
6.Precautions
1. Please confirm with us which industry will be used before purchasing for selection.
2. In order to prevent the sensor from failure, working failure or performance degradation, the anti failure
  function shall be added to the product design, and the product shall not be used under the following or
  similar conditions.
  (a) strong shock or vibration
  (b) prolonged exposure to high temperature and humidity;
  (c)In corrosive gas or sea breeze
  (d)Exposure to dissolved organic matter
  (e)Dusty environment;
  (f)Over allowable input voltage
Product Tag:
Related categories:
Scroll to Top