OME Ejected Lube Oil Mist Eliminator for compressor steam gas turbine
Viking has the ambition to be the hydraulic and lubricating oil filtration, separation and purification experts.
We design and produce the oil mist eliminator/Oil Demister/oil mist separator for gas turbine and steam turbine and air compressor.
We have 2 series for your option:
OMB High Efficiency oil mist eliminator
OME Jet Flow Ejected oil mist sepatator
The device can effectively remove particulate impurities, atomized oil fume and water vapor in flue gas.
OME Jet Flow Ejected oil mist sepatator
Working Principle:
Power Souce: 6bar compressed air
Nozzle Table | |||||
Code | Nominal Dimension/DN | Nominal pressure | Flange standard | Form of flange and sealing surface | functions |
N1 | DN80 | 150# | HG/T20615 | SO RF | Inlet |
N2 | DN100 | PN16 | HG/T20592 | RF | Outlet (with flame arrester) |
N3 | DN25 | 150# | HG/T20615 | SO RF | Compressed air inlet |
R1 | DN15 | 150# | HG/T20615 | SO RF | Oil return port (hose in 3 meters) |
Serial number | Model | Motor Power | Max. Flow Rate | Min. Negative Pressure in Oil Tank |
1 | OMB180E-0.75-150/80-SS | 0.75KW | 180m³/h | -0.5Kpa |
2 | OMB210E-1.1-150/80-SS | 1.1KW | 210m³/h | -0.5Kpa |
3 | OMB350E-1.5-200/80-SS | 1.5KW | 350m³/h | -0.5Kpa |
4 | OMB420E-2.2-200/80-SS | 2.2KW | 420m³/h | -0.5Kpa |
5 | OMB500E-4.0-200/80-SS | 4.0KW | 500m³/h | -0.5Kpa |
6 | OMB700E-5.5-300/100-SS | 5.5KW | 700m³/h | -0.5Kpa |
7 | OMB900E-7.5-300/100-SS | 7.5KW | 900m³/h | -0.5Kpa |
Note: 200 / 80 indicates the size of inlet and outlet flange of oil demister.
Working medium: oily air/ air with oil smog
Working conditions: installation on top of oil station, indoor or outdoor operation
Operating rotation speed: 2900 rpm
System inlet pressure: - 0.2 ~ - 0.5kpa; initial negative pressure at system diagram PG01: ≤ - 0.25kpa; maximum allowable negative pressure: 10KPA;
Power supply condition: 380V, 50Hz, 3Ph
The upper cylinder and lower inlet of lampblack fan are respectively equipped with pressure gauges.
The by-pass pipeline is set at the inlet and outlet of the oil fume exhaust fan, which is connected with the manual stop valve to adjust the air supply volume of the fan.
Ensure that the separator inlet is in zero pressure state when the fan is shut down.
Model selection of OMB High Efficiency Oil Demister
1.Oil Station Flow Rate:<300L / min,choose 1.1KW Motor
2.Oil Station Flow Rate: 300L/min---600L / min, choose 1.5KW Motor
3.Oil Station Flow Rate: 600L/min---1200L / min, choose 2.2KW Motor
4.Oil Station Flow Rate: 1200L/min---1800L / min, choose 4KW Motor
5.Oil Station Flow Rate: 1800L/min---2400L / min, choose 5.5KW Motor
6.Oil Station Flow Rate: 2400L/min---3000L / min, choose 7.5KW Motor
Note: The selection process mentioned above is the standard process for common oil demister. For the oil demister applied on seal gas isolation of gearbox or compressor, a larger model shall be selected. For the oil system with large flow rate (more than 3000L/ min), please ask Viking's engineer for further support.