Full plastic explosion-proof LED linear light is the ideal choice for marine and hazardous applications requiring a linear design.Its rugged construction withstands strong vibrations,saltwater, corrosive elements and hazardousenvironments while the streamlined design sheds water.It can be mounted on ceilings or walls using a pair of stainless steel mounting brackets.
It is designed for use in hazardous locations and flammable buildings that require ATEX/IECEx rated fixtures.
It is constructed of non-sparking materials for protection in flammable work sites and highly resistant to rough impacts.
Certification: | China: CE17.5005X Ex mark: Ex d e mb q IIC T5/T4 Gb Ex tD A21 IP66 T80°C |
IECEx: IECEx CML 16.0116X Ex mark:Ex db eb mb op is q IIC T5/T4 Gb Ex tb op is IIIC T80°C Db | |
ATEX: CML 16ATEX1342X Ex mark: II 2 G D Ex db eb mb op is q IIC T5/T4 Gb Ex tb op is IIIC T80°C Db | |
Intended use: | Can be used in zone 1 and zone 2 |
Can be used in zone 21 and zone 22 | |
Ambient temperature: | T5 at -25ºC≤Ta≤+40ºC |
T4 at -25ºC≤Ta≤+55ºC | |
Degree of protection: | IP66 ( IP64 with breather CZ0527 ) |
Rated voltage: | AC100 ~ 250V 50/60Hz |
Color temperature: | 5700K |
Color rendering index: | Ra≥80 |
Power factor: | λ>0.95 |
Terminals: | L1, L2, L, N, PE, each terminal 2×1.5-10mm² |
Cable entry: | Moulded plastic 1×M25×1.5 cable gland,Outside diameter of cable: Φ8-17mm |
Moulded plastic 2×M25×1.5 stopping plugs | |
Pole mounting:Moulded plastic 1×M25×1.5 cable gland,Outside diameter of cable: Φ8-17mm |
Application areas
Working in potentially explosive areas require explosion proof lighting solutions. We have taken advantage of these multiple technology developments to design a new range of explosion proof LED work lights providing powerful illumination, extreme durability, versatile functionality, and very long lifetime.
The explosion proof work lights are approved and certified according to the latest European ATEX directive.
Caution
-Schematic diagram
1.Before installation, it is necessary to check whether the actual operating conditions are in conformity with the parameters listed on the lamp nameplate.
2.Before installation, please test the lighting according to the parameters of the lamp nameplate to ensure that there is no quality problem before installation.
3.Before installation, it is necessary to determine the installation location and mode of the lamps according to the installation mode provided by the product, in combination with the on-site use environment and lighting requirements, so as to ensure that the installation is firm and reliable.
4.Connect the prepared cables with the input cables of lamps and lanterns according to the corresponding fire (brown), zero (blue) and ground (yellow-green) wires, so as to ensure that the connection is firm, and make good insulation and waterproof measures at the connection.
5.The input end of the cable can be connected to the power supply of the corresponding voltage to illuminate.
-Using The Matters Needing Attention
1. When transporting, the lamp should be installed in the carton equipped with foam shock absorption.
2. When using, the surface of the lamp has a certain temperature rise, which is a normal phenomenon.
3. The power supply voltage can work normally in the rated voltage. If the power supply voltage is too high, the lamp will be damaged; if the voltage is too low, the lamp will not start normally.
4. The luminaire must be reliably grounded.
-Quality Assurance
The company has passed ISO9001:2008 international quality system audit certification, this product strictly implements ISO9001 international quality management system standard production, to ensure that the product quality fully meets national standards and design requirements.
Explosion Proof Exit Light EX proof Emergency Light Explosion-Proof High Bay Light
1.Why is Explosion Proof Lighting necessary in your area?
Plenty of commercial facilities have areas where lighting fixtures can come into contact with hazardous materials. These can be flammable, combustible, or ignitable materials, gases, or vapors. These areas can be at risk of fire or even explosion if the lighting fixtures can't withstand the abnormal conditions.
2.What is hazardous location lighting?
Hazardous location lighting refers to fixtures that you can safely use in an area where it's likely that fire might start. According to the National Electrical Code, hazardous locations are those areas "where fire or explosion hazards may exist due to flammable gases or vapors, flammable liquids, combustible dust, or ignitable fibers or flyings."
3.What is explosion-proof light fixture?
Explosion proof lighting refers to lighting fixtures that are able to contain sparks that could potentially the flammable and explosive gases in the atmosphere. Therefore, explosion proof lighting does not refer to lighting equipment that are resistant to explosions but rather, the capacity to prevent external explosions from occurring in a hazardous location.
Finding suitable lighting for the work site that won't falter under extreme circumstances is what makes it most reliable in any situation. Lamp suite explosion proof lighting is 100% certified with non-spark, durable, and thick materials, along with all necessary features to maintain a high level of safety at all times.
So, what makes Lamp suite different?
Our expertise in solar and technical lighting solutions allows us to give you the appropriate explosion proof lighting to suit you and your business's needs the best. As a result, you can expect outstanding LED performance, lower costs, increased productivity, and safety adherence to give you and your workers total peace of mind.
Lamp suite has a passionate team aiming to help you create a safe working or public environment where workers, pedestrians, shoppers, or anyone nearby can feel comfortable moving around.