Chemical  Cosmetic Flame Atomic Absorption Spectrometry Hollow cathode lamps

 

Specifications:

Mainframe
Model:AA-1800
Light Source:≤6 lamps automatic turret, automatic alignment
Power Supply:110/220V (+5% ~ -10%), 60/50Hz; 5000VA
Lamp Current:pulsed power supply
Optical System:large 1800 /mm grating ruling, full closed optical system
Wavelength Range:180nm-900nm                 
Automatically peak find,a key opticaloptimization function
Wavelength Accuracy:≤0.15nm
Wavelength Repeatability:±0.1nm
Spectral Bandwidth:0.1nm,0.2nm,0.4nm,1.0nm,2.0nm
(5 steps with automatic changeover)
Baseline Stability:≤±0.002A/30 min (Static)     
≤±0.005A/30min (Dynamic)
Absorbance Range:0-4A
Detector:imported photomultiplier tube 
Flame Analytical System
Burner Head:full titanium combustion head, 50mm or 100mm generalcombustion head
Atomization Chamber:polymer explosion-proof spray chamber
Nebulizer:atomizer efficient glass atomizer, can also be customized
Ignition Type:microcomputer control, automatic ignition
Gas Control:automatic gas control system
Detection Limits(Cu):0.002μg/mL
Precision:RSD≤0.5%
Graphite Furnace Analytical System
Heating Mode:vertical heating
Temperature Control Method:vertical optical temperature monitoring graphite tube wall temperature
Temperature Range:room temperature to 3000ºC
The Program:automatic temperature control up to 20 order
Temperature Control:the furnace enriched up to 20 times
Characteristics Volume:0.5 × 10-12g (Cd)
Detection Limit:0.4 × 10-12g (Cd)
Precision:RSD≤3%
The Cooling Water:can choose cooling water circulation system
Safety:the graphite tube damage, water flow
air pressure and other alarmtemperature overheating protection
Autosampler Graphite Furnace
Sample Tray:70 sample cups, 6 reagent cup
Sample Volume:1-100μl
The Smallest Lincrement:0.1 μl
The Volume of Samplebetter than 1%(at the time of 10mL-100mL)
Repeatability Volume
Repeated Sampling Frequency:up to 99 Times
Cleaning and Wasteeach 500mL
Container Volume

 

 

Applications:

 

AA-1800H atomic absorption spectrophotometer is now widely used in scientific research,quality control,

disease control, environmental protection, metallurgy, agriculture,chemical industry .Hardware and

software design of innovation to ensure the accuracy,safety, ease of use in the analysis of samples,

equipment maintenance, simple and convenient

 