Ecl Chemiluminescence Kit for Western Blot Electrophoresis Gel Color Development

Min.Order: 5
Product origin: Wuhan, Hubei, China
Infringement complaint: complaintComplaint
US$ 43 ~ 50

Description
Product information
Product nameCat. No.Specification
Servicebio® ECL ChemiluminescenceG201450 mL×2

Product introduction
The ECL chemiluminescence kit is a highly sensitive chemiluminescence kit based on the principle of Luminol ECL chemiluminescence. This product can chemically react with horseradish peroxidase (HRP) coupled with secondary antibodies to produce fluorescence, and the sample can be detected by X-ray tablet pressing or other appropriate fluorescence imaging equipment (CCD camera, etc.).
The company currently produces two kinds of ECL chemiluminescence kits, which are G2014 ECL chemiluminescence kit and G2020 ultra-sensitive ECL chemiluminescence kit. For the detection of target protein with high abundance, such as internal reference protein, G2014 is recommended, which can detect target protein with content greater than or equal to 2ng. For the target protein with low abundance that is difficult to detect, G2020 is recommended. The sensitivity of this product is at least 5times higher than that of G2014, and it can detect PG-level protein with more stable luminescence.

Storage and transportation
Wet ice transportation; Store at 4ºC away from light and expire for 12 months. If not used for a long time, it can be stored at -20ºC for a longer time.

Specification
Component NumberComponentG2014-50ML
G2014-1ECL A solution50 mL
G2014-2ECL B solution50 mL
                       Manual1


Operating steps:
1. Preparation of ECL working fluid: Mix ECL A liquid and ECL B liquid in equal volume, and keep them at 4ºC away from light. Use it right after it is ready, within 2 days.
2. In the Western blot experiment, PVDF membrane was incubated by the secondary antibody, washed for several times, and the excess liquid was absorbed by the filter paper. Two layers of PE gloves or other transparent films were affixed to the exposure box. The PVDF membrane protein was placed face up between the two layers of the exposure box. The mixed ECL working solution was added to cover the film and placed on the film for 1-2 min.
3. Use filter paper or absorbent paper to absorb ECL working liquid, cover the upper film and start pressing film.
4. Development and fixing reagents (G2019, G2023 and G2024 are recommended) shall be used to develop and fix the pressed film.Adjust the exposure conditions according to the luminous intensity.

Notes:
1. The pipette tips must be replaced during the liquid transferring process of ECL liquid A and liquid B. Cross contamination of liquid A and liquid B will lead to the gradual failure of liquid A or B. In addition, the contamination of metal ions will reduce the sensitivity of this reagent. Please pay attention to use clean pipette tips, Seal well after use.
2. If the background after exposure is very deep, the reason may be that the concentration of the secondary antibody is too high, or the concentration of the primary antibody is too high, or the sealing solution is not suitable, and other sealing solution should be used.
3. If the fluorescence quenches rapidly, it may be due to the over-strong fluorescence of the target band, resulting in the rapid consumption of ECL by HRP.
4. If there is no luminous signal, it may be that the target protein expression is very weak, which can prolong the tablet pressing time.
5. Please wear a lab coat and disposable gloves during operation