 Drawer/Fixed Intelligent Universal Air Circuit Breaker Acb 
 

Product Description

 Air Circuit Breaker

Rated operational voltage of the breaker is AC400/415/690V, with the rated current ranges from 400A to 6300A 
Compact design with fixed and withdrawerable type 
Standard of ACB: IEC/EC 60947-2 
Telecommunication protocal: The protocals of Modbus, Profibus-DP and Device Net are avaiable 

 1.Temperature condition:-5°C~40°C;The average value within 24h shall not exceed+35°C(special situation  excluded);

2 Altitude:≤2000m;

3 Pollution grade:Grade 3;

4 Air conditions:

At mounting site, relative humidity not exceed 50% at the max temperature of +40°C, higher relative humidity is Allowable under lower temperature,RH could be 90% at +20°C, special measures  should be taken to occurrence of dews;

Model       
IEC60947-2 GB/T14048.2
Shell frame level current Inm(A) 10002000320040006300
Electrical Performance        
Number of poles  3P4P3P4P3P4P3P4P3P4P
Operating frequency(Hz) 5050505050
Rated working voltage  Ue(V) 400/690400/690400/690400/690400/690
Rated current +40ºC  In(A) 200,400,630,800,1000630,800,1000,1250,1600,20002000,2500,32003200,3600,40004000,5000,6300
Rated insulation voltage Ui(V) 8001000100010001000
Rated impulse withstand voltageUimp(kV) 812121212
Pole N rated current  In(A) 100%100%100%100%100%
Breaking type   -MH --
Rated ultimate short-circuit segmentation capability        Icu(kA)400V5085100100120
690V3050656580
Rated running short-circuit segmentation capability        Ics(kA)400V355065656580
690V2540505070
Rated short-time withstand current(effective value)Icw(kA)400V35(1s)50(1S)65(1S)65(1S)65(1S)85(1S)
690V25(1S)40(1S)50(1S)50(1S)65(1S)
Operating time(ms)Disjunction23~3223~3223-3223-3223-32
Switch off<70<70<70<70<70
Flashover distance(mm) 00000
Service lifefor mechanicalFree of maintenance1500010000500050003000
service life(times)Maintained300002000010000100006000
Electrical life (times)400V6000650030001500500
900V300030001500750300
Separating function (drawer type)OOOOO
Protection:
Intelligent controllerOOOOO
Pole N protection capability (only 4P and 3P+N)OOOOO
Connection And Installation:
Utilization categoryBBBBB
Installation categoryCircuit breaker(including the primary lateral line circle)IVIVIVIVIV
Auxiliary circuit (except for primary coil RB)IIIIIIIIIIIIIII
Pollution degree 33333
Connection mode HorizontalVertical/HorizontalVertical/HorizontalVertical/HorizontalVertical/HorizontalVertical/Horizontal
Incoming line methodUp/DownUp/DownUp/DownUp/DownUp/Down
Installation MethodFixed Type (3/4)Drawer Type(3/4)Fixed Type (3/4)Drawer Type(3/4)Fixed Type (3/4)Drawer Type(3/4)Fixed Type (3)Drawer Type(3/4)Fixed Type (3/4)Drawer Type(3)



AIR CIRCUIT BREAKER STRUCTURE