It absorbs the advantages of similar products at home and abroad, continuously innovates and improves, and solves a series of problems such as frequent maintenance and cost of slag coolers, water leakage and slag blocking, high slag discharge temperature, and short service life that exist in similar products. It can effectively ensure the continuous and stable operation of the equipment. It is a slag cooler produced by the technology of double-spiral heat fins and solid-welded cold slag heat exchange tubes.
Main structure:
This product adopts a parallel multi-channel split cooling method, which consists of a feeding chamber, a discharging chamber, a driving device, a plurality of cooling and heat exchange tubes, a rotating simplified structure, a frame and other parts.
Working principle:
The boiler slag drop pipe is directly connected to the slag inlet of the machine. During operation, the cylinder is driven by the driving device to run at a low speed, and the inlet and outlet valves are opened at the same time, so that the cooling water (about 30°C) fills the cylinder and maintains a certain flow. The high-temperature slag enters each cooling channel uniformly through the feeding chamber, and the cooling channel is provided with spiral heat-absorbing fins, which play a driving role. The slag travels a certain distance in the cooling channel every time it rotates. With the continuous rotation of the simplifier, the slag and the cooling water flow through each heating surface in the opposite direction for heat exchange, so that the temperature of the slag is lowered, and the hot water enters the deaerator.
Model | DL2-3 | DL4-5 | DL6-8 | DL10-12 |
Output(T\h) | 2-3 | 4-5 | 6-8 | 10-12 |
(°C)Inlet slag temperature | 800-1000 | 800-1000 | 800-1000 | 800-1000 |
(°C)Outlet slag temperature | 60-80 | 60-80 | 60-80 | 60-80 |
(°C)Inlet water temperature | 20-30 | 20-30 | 20-30 | 20-30 |
(°C)Outlet water temperature | 50-90 | 50-90 | 50-90 | 50-90 |
(Mpa)Water pressure | 0.3-2.0 | 0.3-2.0 | 0.3-2.0 | 0.3-2.0 |
(m³)Water volume | 6 | 12 | 18 | 24 |
(r/Min)Rated speed | 4 | 4 | 4 | 4 |
(KW)Rated power | 1.1 | 1.5 | 2.2 | 3 |
Water quality | Demineralized water |