Medical Digital Mammography System Xray Machine for Women

Min.Order: 1
Product origin: Guangzhou, Guangdong, China
Infringement complaint: complaintComplaint
US$ -1

Description
Product Description

Product Parameters
Digital Mammography System
    
High voltage generatorTypeHigh frequency inverter type
 X-ray tube voltage20-40kV(step 0.5kV)
 X-ray tube current10mA-160mA
 Maximum output power5kW(40kV,125mA)
 Nominal power4.8kW(30kV,160mA,0.1s)
 Radiograph time0.005-10s
 mAs0.5mAS~560mAs
 Minimum mAs0.5mAs(50ms 10mA)
 Maximun mAs560mAs
 Minimum mAs in AEC6.3mAs
 Exposure controlmanual ,semi-auto,auto
 Radiating modecross-ventilation
    
X-ray tube XM15HMT-113
  small focus/big focussmall focus/big focus
 Focus size0.1mm/0.3mm0.1mm/0.3mm
 Maximum anode heat capacity225kJ(300kHU)225kJ(300kHU)
 Maximum heat dissipation500W500W
 Anode cooling modeoil coolingoil cooling
 Nominal voltage40kV40kV
 Target angle15°10°/16°
 Target materialMoMo
 Radiation field18cm-50cm18cm-50cm
 Inherent filtration0.5mmBe0.5mmBe
 Additional filtration0.03mmMo/
 Anode speedlow-speed3000r/min; high-speed 10000r/minlow-speed3000r/min; high-speed 10000r/min
 Anode input power1.15-2KW / 4.8-9kW0.7-1.35kW / 2.9-4.9kW
X-ray tube socket (C339v)  
 Additional filtration0.03mmMo
 Weight13kg
   
C Arm frame  
 vertical range of motion630-1400mm,deviation±5%
 Rotation range of motion+195°~-155°Angular division value 1°,deviation±2%
 FID660mm,deviation±5%
 3D tomographic axial rotation+30°~-30°deviation±2%
 Rotate Modepower-drive double speed rotate
  Preset angle and memory function
Oppression platerange of motion245mm,deviation±10%
 range of motion in 1.5 times platfo150mm,deviation±10%
 range of motion in 1.8 times platfo75mm,deviation±10%
 Operation modeManual/Auto
 Pressure range0-300N(Manual)150-200N(Auto)
   
FPD AXS-2430HMD-2430
 Pixel unit85um85um
 Effective pixel size239.36*304.64mm239.36*304.64mm
 Pixel matirx2816*3584 pixels2816*3584 pixels
 Spatial resolution≥7 lp/mm≥7 lp/mm
 Cooling modefan coolingfan cooling
 Grayscale≥16bit≥16bit
 DQE≥50%≥50%
    
Grid   
 Grid proportion5:1
 Size338*264mm
 line pair36lp/cm
 focus66cm
   
Collimator (HMC-915)  
 Power supply24V DC,2A
 Radiation fieldMin 5*5cm/Max 24*30cm
 Radiograph platformField 24*30cm SID 660mm,deviation±5%
 1.5 times radiograph platformField 16*20cm SID 440mm,deviation±5%
 1.8 times radiograph platformField 13.6*16.7cm SID 366.7mm,deviation±5%
 Inherent filtration0.02mmAl
 Additional filtration0.03mmMo /0.025Rh
 Illumination in max SID>160Lux
 TimerButton/Auto,30s timer
 Indicator lightLED
 maximum radiation leakage<40mRh
 Light field switchAuto
 Weight3.6kg
   
   
   
Image Acquisition WorkstatScreen size/resolution19",Resolution 1280*1024,Contrat 1000:1
 Memory≥8G
 Hard disk≥320G
 OSWin7
 Image formatDICOM3.0(can connect with RIS)
 Image storage capacity≥20000 images
  mamual input patients' date or download form HIS/RIS through DICOM Worklist
  CD-R writer (storage image)
  Choosing Breast implants Function
  Integrated design with High voltage generator, exposure specification setting in workstation
   
Imaging
 

 

Certifications

Packaging & Shipping

Company Profile

Product Tag:
Related categories: