Macylab Instrument Inductively Coupled Plasma Optical Emission Spectrometer Icp

Min.Order: 1
Product origin: Shanghai, China
Infringement complaint: complaintComplaint
US$ 37387

Description
Detailed Product Description

 

Shipping/Storage Ambient Temperatur:15ºC-25ºCAtmospheric Pressure:≤70%
Power Supply:220±10V 50-60MHzWorking Humidity:≤70%
Working Temperature:Away From The Instrument, Electric Field: E<2V/mName:ICP-6800 Inductively Coupled Plasma Optical Emission Spectrophotometer
High Light:

inductively coupled plasma optical emission spectrophotometer

,
ICP

-6800 inductively coupled plasma optical emission spectrophotometer


ICP-6800 Inductively Coupled Plasma Optical Emission Spectrometer(standard)
 
ICP-6800 Inductively Coupled Plasma Optical Emission Spectrometer(standard)

 

 Inductively coupled plasma emission spectrometer(ICP6800) developed by Macylab Instruments with many years of technology accumulation. It is used to measure traces and traces of various substances (dissolvable in hydrochloric acid, nitric acid, hydrofluoric acid, etc.),and the content of metal elements or non-metallic elements. It is stable and reliable and with high degree of automation and easy operation.
 At present, instruments are widely applied in various fields such as rare earth, geology, metallurgy, chemical industry, environmental protection, clinical medicine, petroleum products, semiconductor, food, biological samples, criminal science, agricultural research and so on.
 

Main Features


Performance stability
The use of all-solid-state rf power supply, with small size, high efficiency, stable output power, with a variety of protection functions and many other advantages, the load using fully automatic matching technology, matching speed, improve the efficiency of the use of power supply and the stability of the instrument, and make the whole ignition process simple and convenient.

 

Injection automation

The instrument is equipped with a four-channel twelve-roller high-precision peristaltic pump, which can guarantee the precision of injection and prevent liquid accumulation at the same time. The speed of the peristaltic pump can be adjusted continuously to meet various test requirements of customers.

 

Flow control parameters

Adopt imported high precision mass flow controller.

 

High precision constant temperature system

The whole optical path of adopt the precision constant temperature protection system. The temperature control can be set in real time according to the actual ambient temperature of the customer's laboratory, without the need to turn on the air conditioner continuously for a long time. Temperature control precision ≤±0.1%, precision constant temperature protection system to ensure the stability of the optical path and makes the test data more stable.

Product Parameters

 

RFPower technical parameter

 

Circuit type

solid-state RF Power supply, with function of automatch

Frequercy

27.12MHz±0.05%

Frequency Stablity

<0.1%

Power Output

800W-1200W

Power Output Stability

<0.3%

Escaped RF radiation

30cm away from the instrument, electric fiekd: E<2V/m

Sampling System Technical Parameter

 

Output working coil imer diameter

25mm

Torpue tube

Three concentric, extemal diameter 20mm

Coaxial nebulizer

Outer dameter 6mm

Double barrel atomizing chamber

Outer diameter 34mm

 

Gas Flow Controls

 

Plasma Argon Flowmeter

(100-1000)L/h(1.6-16L/min)

Auxiliary Argon Fiowmeter

(10-100)L/h(0.16-1.66L/min)

Auxiliary Carrier Argon Flowmeter

(10-100)L/h(0.16-1.66L/min)

Pressune Maintaining Value

(0-0.4MPa)

Cooling Water:Temperature

20-25ºC,Rate of Flow>5L/min,Hydraulic Pressure>0.1MPa

 

Spectrometer

 

Optics

Czerny-Turner type

Focal length

1000 mm

Grating

Ion Beam Etching Holographic Grating, 3600L/mm or 2400L/mm

Reciprocal linear dispersion

0.26nm/mm

Resolution

≤0.007nm(3600 line grating); ≤0.015nm(2400 line grating)

Wavelength range

3600 line grating:(190nm~500) nm; 2400 line grating:(190nm~800) nm

Minimum pace of stepping motor

≤0.0006 nm

Exit Slit

12μm

Entrance Slit

10μm

 

Photoelectric Converter Performance

 

Photomultiplier tube specification

R293/R928

Negative HV on PMT

0-1000V

Stability

<0.05%

Overall Performance

Wavelength range of scanning: 195nm~500nm(3600L/mm line grating);195nm~800nm(2400L/mm line grating)

Repeatability: RSD(Relative Standard Deviation)≤1.5%

Stability: RSD(Relative Standard Deviation) ≤2%

Detection Limits (µg/L):

 

ElementWL(nm)Limit ElementWL(nm)Limit
La408.672<3.0 Cr267.716<5.0
Ce413.765<5.0 Al396.152<5.0
Pr414.311<5.0 Zr343.823<5.0
Nd401.225<5.0 Ag328.068<3.0
Sm360.946<10.0 Sr407.771<1.0
Eu381.967<1.0 Au242.795<5.0
Gd342.247<10.0 Pt265.945<5.0
Tb350.917<3.0 Pd340.458<5.0
Dy353.170<3.0 Ir224.268<10.0
Ho345.600<3.0 Rh343.489<10.0
Er337.271<3.0 Ru240.272<5.0
Tm313.126<3.0 Ba455.403<1.0
Yb369.419<1.0 As228.812≤15
Lu261.541<3.0 Sb206.833≤15
Y371.030<1.0 Bi223.061≤10
Sc335.373<1.0 Hg253.652≤15
Ta226.230<5.0 Pb220.353≤15
Nb313.340<5.0 Ga294.364≤10
Mn257.610<3.0 Se203.985≤10
Mg279.553<1.0 Sn242.949≤20
B249.773<10.0 Te214.281≤10
Zn213.856<3.0 Ta226.230≤5.0
Co228.616<3.0 Th283.730≤10
Si251.611<10.0 Tl276.787≤30
Ni232.003<5.0 Re227.525≤5
Cd226.502<3.0 Ge209.426≤15
Fe239.562<3.0 Os225.585≤1
Ca393.366<1.0 W207.911≤10
Mo281.615<5.0 Cu324.754<3.0
V310.230<5.0 Li670.784≤3
Be313.041<1.0 Na588.995≤20
Ti334.941<3.0 K766.490≤60

plication F

Application Fields

Inductively coupled plasma emission spectrometer(ICP6800) developed by Macylab Instruments with many years of technology accumulation. It is used to measure traces and traces of various substances (dissolvable in hydrochloric acid, nitric acid, hydrofluoric acid, etc.),and the content of metal elements or non-metallic elements. It is stable and reliable and with high degree of automation and easy operation.

At present, instruments are widely applied in various fields such as rare earth, geology, metallurgy, chemical industry, environmental protection, clinical medicine, petroleum products, semiconductor, food, biological samples, criminal science, agricultural research and so on.

 

 

Application Fields

Certificates


Application FieldsApplication Fields

 

Company Profile

 

 

Exhibitions
R&D
 

 

 

 

                                                                                                                           Application Field                                                                                                                          Certificate                                                                                                 Company profile                                                                       

 