Portable Medical ICU Surgical Operation Room Operation Anesthesia Dual Two Channel Syringe Pump

Min.Order: 1
Product origin: Nanjing, Jiangsu, China
Infringement complaint: complaintComplaint
US$ 300 ~ 600

Description
 
1.Easy operation
Brand new appearance provide better experience
Clearly LCD and digital tube dual display
Simple rate mode with one key start,easy to operate
2.Precision more safer
Three occlusion level for option
Intelligent recognition of the 10ml,20ml,30ml,50ml(60ml)
syringe,can work with any brand syringe after calibration
3.Intelligent & safe
Low noise and less vibration are supported by application of motor driver IC imported from German and motor imported from Japan.
Unique voice,word and light combination alarms,very faster and reliable
Can be stackable to save space

 
 
 
 
Model
SP-2000T& SP-2000TU
Infusion Rate
50(60)ml Syringe 0.1ml/h---999.9ml/h(0.1ml/h step) 
1000mh/h---1500ml/h (1ml/h step) 
30ml Syringe 0.1ml/h---900ml/h(0.1ml/h step)
20ml Syringe 0.1ml/h---600ml/h(0.1ml/h step) 
10ml Syringe 0.1ml/h---300ml/h(0.1ml/h step)
Rate Accuracy
Within±3%(after correct calibration)
Purge Rate
50(60)ml Syringe:1500ml/h 
30ml Syringe:900ml/h 
20ml Syringe:600ml/h 
10ml Syringe:300ml/h
Mechanical Accuracy
Within±2%
Bolus Rate
50(60)ml Syringe:1200ml/h 
30ml Syringe:720ml/h 
20ml Syringe:480ml/h 
10ml Syringe:240ml/h
Equipment Classification
Class I,intermal power supply,Type CF
Fuse
T2AH/250V,2pcs installed
Power Consumption
35VA
KVO Speed
1m/h
Audible and Visible Alarms
Occlusion,Equipment failure,Software Exception,Injection finish,Limited finished,Battery running out,Improperly installed
,Abnormal operation ect.
Occlusion
High 800mmHg±200mmHg(106.7kPa±26.7kPa) 
Medium 500mmHg±100mmHg(66.7kPa±13.3kPa) 
Low 300mmHg±100mmHg(40.7kPa±13.3kPa)
Total Injection
0.1ml---9999.9ml(0.1ml step)
Volume Limit
0.1ml---9999.9ml(0.1ml step)
Maximum Infusion Pressure
150kPa
Bolus Rate
50(60)ml Syringe:1200ml/h 
30ml Syringe:720ml/h 
20ml Syringe:480ml/h 
10ml Syringe:240ml/h
Power Source
100-240Vac,50/60Hz;Internal rechargeable Li battery,capacity³1800mAh,voltage=11.1V,4 hours backup time at the rate of25ml/h(appointed medium rate in IEC60601-2-24)for the new battery charged for 12 hours.To facilitate the use in some special
occasions,the machine's DC outlet can be an external DC 12V 2A standby power supply.
IP Classification
IPX2
Syringe
Compatible with 10ml,20ml,30ml,50/60ml syringe of any brands after correct calibration The following brands of syringe sets are
recommended:Dispovan,Romsons,BBRAUN,SHINVA
Syringe maximum value (under single fault condition)
1ml
Dimension
280mm(L)×255mm(W)×205mm(H)
Net Weight
3.6kg
Package Reference
1pc Carton:4.6KG,34cm(L)×32cm(W)×26cm(H) 
2pcs Carton:9.2KG,76cm(L)×30cm(W)×36cm(H)




 
Product Tag:
Related categories:
Scroll to Top