SPECIFICATIONS | ||||
OUTPUT | ||||
Model | HDR-30-5 | HDR-30-12 | HDR-30-15 | HDR-30-24 |
DC Voltage | 5V | 12V | 15V | 24V |
Rated Current | 3A | 2A | 2A | 1.5A |
Current Range | 0-3A | 0-2.5A | 0-2A | 0-1.5A |
Rated Power | 15W | 24W | 30W | 36W |
Ripple & Noise | 80mVp-p | 120mVp-p | 120mVp-p | 150mVp-p |
Voltage Adj. Range | 4.75-5.5V | 10.8-13.2V | 13.5-16.5V | 21.6-26.4V |
Voltage Tolerance | ±2% | ±1% | ±1% | ±1% |
Line regulation | ±1% | ±1% | ±1% | ±1% |
Load regulation | ±1% | ±1% | ±1% | ±1% |
Setup, Rise, Hold Up Time | 100ms,30ms/230VAC 100ms,30ms/115VAC at full load 100ms/230VAC 21ms/115VAC at full load | |||
Voltage Range | 85~264VAC 47~63Hz; 120~370VDC | |||
AC Current | 0.88A/115V 0.48A/230V | |||
Efficiency | 74% | 81% | 82% | 83% |
Inrush Current | Cold start 15A/115V 30A/230V | |||
Over Load | 105%~160% rated output power | |||
Protection type: Constant current limiting, recovers automatically after fault condition is removed | ||||
Over Voltage | 5.75-6.75V | 13.8-16.2V | 17.25-20.25V | 27.6-32.4V |
Protection type: Shut down o/p voltage, re-power on to recover | ||||
Working Temp., Humidity | -20ºC~+60ºC; 20%~90% RH non-condensing | |||
Storage Temp., Humidity | -40ºC~+85ºC; 10%~95%RH | |||
Temp. Coefficient | ±0.03%/ºC(0~50ºC) | |||
Vibration | 10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 | |||
Withstand Voltage | I/P-O/P: 3KVAC | |||
Isolation Resistance | I/P-O/P: 100M Ohms / 500VDC/25ºC/70% RH | |||
Safety Standard | Design refer to UL60950-1,TUV EN60950-1,EN50178 | |||
EMC Standard | Design refer to EN55011,EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11,EN55024,EN61000-6-2,EN61204-3, heavy industry level, criteria A | |||
Dimension | 98*35 *58mm | |||
Weight | 0.2Kg | |||
Packing | 48pcs/14Kg/1.02CUFT |