Plastic Without Ethylene Oxide Sterilization Collection Universal Viral Transport Kit

Min.Order: 10,000
Product origin: Taizhou, Jiangsu, China
Infringement complaint: complaintComplaint
US$ 0.3 ~ 1

Description
Product NameViral transport medium tube with swab
Model/Typetest / box, 20 tests / box, 30 tests / box, 50 tests / box, 100 tests / box
Intended UseThe product is intended is used for collection, transportation and storage of samples(viruses, chlamydiae, mycoplasma and ureaplasma).
IndicationUsed for collection, storage and transportation of viruses, chlamydiae, mycoplasma and ureaplasma.
Contraindication
 
The product is strictly prohibited for the sampling of bacterial samples, and the preservative liquid itself contains antibiotics which inhibit the bacteria.
Test populationApplicable for all population necessary for swabbing
Intended usersQualified doctors, nurses for specimen collection in a medical laboratory or hospital
ComponentIt is usually composed of swabs and / or cups and tubes containing preservative fluid.
Scope of applicationIt is used for collection, transportation and storage of samples.
Precautions/cautions1.After sampling, the disposable sampler should be inspected as soon as possible, and transported immediately at low temperature of 2-8 degrees. The samples collected can be stored for 2-8 hours at a low temperature for 48 hours. The long-term storage should be kept at low temperature below -20 C, and stored at -70 C or -196 C.
2. the product is strictly prohibited for the sampling of bacterial samples, and the preservative liquid itself contains antibiotics which inhibit the bacteria.
3. prohibit direct contact with the patients being collected, and remove the wet swabs before sampling the patients.
4. sampling should be done strictly according to the sampling procedure, so that the sampling location is accurate and the sampling intensity is uniform. Otherwise, the quality of sample collection will be affected.
5. the product should not be used after the expiration date or the product package is damaged.
Warning
 
  1. This product is a disposable product, so it is forbidden to reuse. After use, it should be treated as medical waste; 
  2. Before use, please pay attention to whether the packaging and products are damaged or have other obvious defects. Please check whether the product is within the validity period. If it is beyond the validity period, please do not use it. 
3. Please read the relevant instructions carefully before use, and be familiar with the instructions and operation methods of the product. 
Instruction for use1.Sterilization of the sampling tube and swab can be done before the medical institution or the user is used.
2.Annotate the relevant sample information on the sampling tube and inject an appropriate amount of sample solution.
3.According to different sampling requirements, sample swabs were sampled at the corresponding locations, holding the handle gently inserting the swab into the sampling area, gently rotating the swab 3-5 times, and then slowly removing it.
4.The sample is put into the sampling tube, and the sample swab is broken out of the sampling tube, then the tube cover is tightened, and the sample is sealed to complete the sampling.
5.The newly collected clinical specimens should be transported to the laboratory within 48 hours at 4ºC, and can not be sent to the laboratory for 48 hours. They should be kept at -70ºC or below. Specimens sent to the laboratory should be inoculated and separated as soon as possible, and can be stored at 4ºCfor 48 hours. If the inoculum is not inoculated, it should be kept at -70 ºC or below.
6.The conventional sampling methods are as follows:
A) nasal swab: gently wipe the swab head into the nasal passages of the nasal passages, and then slowly exit after stopping for a moment. Wipe the other nostrils with another swab, immerse the swab head in the sample, and discard the tail.
B) pharyngeal swabs: wipe the bilateral pharyngeal tonsils and the posterior pharyngeal wall with swabs, immerse the swab head in the sampling fluid, and discard the tail.
C) gargle: gargle with 10mL normal saline, rinse the head back, make the "Oh" sound, let the saline rotate in the pharynx, and collect the lotion with the 50mL empty sampling tube.
D) nasal lotion: the patient took his posture and his head was slightly backward, injecting 50mL normal saline into the nostril by pipette. He told the patient to simultaneously send K tone to close the pharyngeal cavity, then let the patient lower his head and let out the normal saline, collect the lotion with 50mL empty sampling tube, and repeat the process to wash the two nostrils.
E) nasopharyngeal aspirates: tracheal and bronchial secretions are often collected by this method. Mucus is extracted from the nasopharynx with a collector connected to a negative pressure pump. First, the collector head is inserted into the nasal cavity, and the negative pressure is turned on. The head of the collector is collected and slowly pushed out. Collecting mucus and washing the collector with liquid 5mL for three times.
F) autopsy specimens: autopsy tissue specimens were collected and samples were separated when necessary. Specimens were autopsy tissue.
G) samples of mycoplasma, chlamydia and Ureaplasma samples: male: use sterile cotton swabs to rotate around the urethra about 2cm for a few seconds. Female: remove the mucus from the cervical mucus and insert the 1-2cm into the cervical canal with sterile swab
Shelf Life
 
18 months
Duration
 
Single-use only
Contraindication
 
The product is strictly prohibited for the sampling of bacterial samples, and the preservative liquid itself contains antibiotics which inhibit the bacteria.
Warning
 
1.This product is a disposable product, so it is forbidden to reuse. After use, it should be treated as medical waste; 
2.Before use, please pay attention to whether the packaging and products are damaged or have other obvious defects. Please check whether the product is within the validity period. If it is beyond the validity period, please do not use it. 
3.Please read the relevant instructions carefully before use, and be familiar with the instructions and operation methods of the product. 
Storage condition
 
Store at ambient temperature and store in dry and ventilated places. Be careful of damp. Do not store with poisonous or special smell. Avoid direct contact with fire sources and inflammable and corrosive substances.
This product is a virus sampling kit consisting of a preservation tube (with built-in virus sample preservation solution) and a sampling swab. This product is suitable for nucleic acid extraction of various influenza virus, avian influenza virus,  and other virus samples. It is also suitable for sample collection and transportation of chlamydia, mycoplasma, and ureaplasma urealyticum. Samples are usually collected from the mouth, throat, nasopharynx, anus and other parts of the human body.
The built-in virus sample preservation solution is divided into non-inactivated solution and inactivated solution.
Non-inactivated type: built-in 2ml clear/pink solution, suitable for virus preservation, can maintain virus activity in a wide temperature range and keep the originality of the sample as much as possible. Lysate-free, maintains pathogen activity and integrity.
Inactivated type: built-in 2ml of guanidine-free solution, which can stably preserve viral nucleic acid at room temperature without being degraded, which can prevent the nucleic acid in the sample from degrading before detection, resulting in wrong nucleic acid detection results.

Certifacation
RELATED PRODUCTS
WHY CHOOSE US?
FACTORY SHOW
JIANGSU HXRT MD CO., LTD. is located in No.66 Xingyuan Road, the Modern Science and Technology Industrial Area,  Jiangyan District, Taizhou City,225300, Jiangsu, China. It is an enterprise specialized in manufacturing disposable medical plastic ware. With unremitting effort, the Company has come a long way and accumulated rich practical experience.

HUAXIARUITAI always treats the product quality as vitality. Following the International standards,  we has established a whole set of strict inner quality control system and passed ISO9001,ISO13485,CE,FDA,CE0197 and TUV ISO13485 approval. Good quality and stability guarantees the testing data accurate and effective. Meanwhile, competitive price has made HUAXIARUITAI's products preferred in the medical market.

Under the marketing concept of humanistic service, HUAXIARUITAI keeps on doing the primary technology R&D, with a view to the filed of life sciences, gene organization and cell engineering, etc. In the meantime of increasing technology content, HUAXIARUITAI also applies for many invention and new-style utility patents, which is enhancing his core competence step by step.


Advanced technical equipment and systematic training for the staff continuously improve HUAXIARUITAI's manufacturing technique and service quality for clients. We will strive to sincerely cooperate and make progress together with all the clients just as in the past, to make due contributions to human medical and health services
WORKSHOP EQUIPMENT
More certificates
Product Tag:
Related categories:
Scroll to Top