150m 75m 14AWG-2AWG Roll, Coil, Sandard Rxpot Wooden Drums Canadian Non-Metallic Sheath Wire

Min.Order: 20,000
Product origin: Tangshan, Hebei, China
Infringement complaint: complaintComplaint
US$ 0.84 ~ 1

Description


CUL certificate 14/2 NMD90 wire Solid Non-Metallic Wire Basic Electrical for Wiring House Wire Types Sizes
 

1. Application:

 

NMD90 cables may be used for both exposed work in dry locations or concealed work in dry or damp locations.

NMD90 cables may be used for both exposed work in dry locations or concealed work in dry or damp locations.

The maximum allowable conductor temperature is 90°C. The minimum recommended installation temperature is -25°C

for two-conductor cables and -10°C for three-conductor cables (with suitable handling procedures). Material should be

properly stored above 0°C for 24 hours prior to installation.

The maximum voltage rating for all intended applications is 300 volts. Consult the Canadian Electrical Code1 for further

information related to applications.

 

SPECIFICATIONS

Type NMD90 cable complies with:

ASTM

C22.2 No. 48 (non-metallic sheathed cable)

Canadian Electrical Code1

 

CONSTRUCTION

NMD90 cables are available as two- or three-conductor cables with a bare grounding conductor. It is manufactured using annealed (soft) copper conductors-compressed standing for stranded conductors; a heat-resistant thermoplastic polyvinyl chloride (PVC) insulation and nylon jacket for the individual conductors with a PVC jacket for the overall construction.

 

Conductors are white, black and red (for 3 conductor cables). Cable jackets are colour coded by size for quick identification in the Table below:


JACKET COLOUR CODE - Typical Application Guide

•WHITE - General Residential Wiring

•RED - 2 Black and Red conductors - 208V-240V Circuits (no neutral)

•ORANGE - No. 10 AWG General Residential Wiring

•YELLOW - No. 12 AWG General Residential Wiring

•BLUE - No. 14 AWG - 2 black and white conductors - 120V Arc Fault Circuit Interupter Applications

 

CABLE PRINTING

12 AWG 2 CDRS BLACK/WHITE NMD90 NYLON 300 VOLTS FT1

 

 

NMD90 jackets which reduces the coefficient of friction, allowing cables to be installed without external

lubricants, resulting in reduced labour and materials costs.

 

Specification:

 

Conductor

Insulation

Ground

Approx. Jacket thickness

Approx. Cable Dia.

Approx. Cable weight

Allowabl e Ampaciti
es 30°C

Size (AWG)

Cores

Strands

Inches

mm

Size (AWG)

Core

Inches

mm

Inches

mm

Ib/ 1000ft

Kg/ km

 

14

2

1

0.034

0.86

14

1

0.030

0.76

0.388*0.192

9.86*4.88

68

101

25*

14

2

1

0.034

0.86

14

1

0.030

0.76

0.388 x 0.192

9.86 x 4.88

68

101

25*

12

2

1

0.034

0.86

14

1

0.030

0.76

0.422 x 0.209

10.71 x 5.30

86

129

30*

10

2

1

0.034

0.86

12

1

0.030

0.76

0.481 x 0.230

12.21 x 5.84

122

182

40*

8

2

7

0.040

1.02

10

1

0.045

1.14

0.636 x 0.312

16.15 x 7.92

208

310

55

6

2

7

0.051

1.30

8

7

0.045

1.14

0.792 x 0.370

20.12 x 9.40

315

468

75

14

3

1

0.034

0.86

14

1

0.030

0.76

0.345

8.77

86

128

25*

12

3

1

0.034

0.86

14

1

0.030

0.76

0.381

9.69

114

169

30*

10

3

1

0.034

0.86

12

1

0.030

0.76

0.427

10.85

163

242

40*

8

3

7

0.040

1.02

10

1

0.045

1.14

0.570

14.47

275

408

55

6

3

7

0.051

1.30

8

7

0.045

1.14

0.695

17.65

421

627

75

3

3

7

0.051

1.30

6

7

0.080

2.03

0.925

23.48

799

1189

115





Product Tag:
Related categories:
Scroll to Top