Aluminum Conductor PVC/XLPE/PE Insulated PVC Sheathed Low/Medium Voltag Electrical Wires

Min.Order: 100
Product origin: Xingtai, Hebei, China
Infringement complaint: complaintComplaint
US$ 1 ~ 10

Description
Product Description

 Aluminum Conductor PVC Insulated Underground Cable

1.The long-time permissible working temperature of cable conductive core is not more than 70 °C.

2.During short circuit (max. permanent time is not more than 5 seconds), the max temperature of cable conductor is not more than 165°C.

3.The difference level of laying cable is not restricted.When laying the cable,ambient temperature is not lower than 0°C.

4.They have good chemical stability,and properties of acid resistance,alkali resistance,salt resistance,oil resistance,solvent resistance and flame resistance.rty

5.Light weight,good bending property and easy installation and maintenance.


Structure 

 

Standards
The products can be produced in accordance with GB, IEC, BS, and other standards.

 Basic Information
Model No: VV/VLV/VV22/VV32
Material Shape: Round Wire
Certificate: ISO9001,ISO14001, CCC, CE       
Origin: Hebei, China.
Voltage: 0.6/1kv
Current: AC & DC
Insulation Material: PVC
Sheath Material:PVC
Material Shape: Round wire


Application
With the characteristics of stable capability,advanced technology,broad material resources,low price, good flexible and easy to lay and maintain, the PVC Insulated and Sheathed Power Cable are suitable to be laid for distribution line with A.C.50HZ and rated voltage up to 6kV.
 

Product Parameters
Executive Standard:ASTM     
  Bare neutral MessengerPhase conductor      
Code WordAWG or kcmilAAACRated StrengthAACinsulation thickness (m m )Weight (kg/km )     
  s trading and w ires dia(mm )(lbs )strading and wires dia(mm )      
Bay3*6AWG+ 1*30.587/ 1.6811101/4.111.14207     
French Coach3*6AWG+ 1*30.587/ 1.6811107/ 1.561.142 13     
German Coach3*4AWG+ 1*48.697/2. 1217601/5.1 91.14309     
Arabian3*4AWG+ 1*48.697/2. 1217607/ 1.961.14316     
Belgian3*2AWG+ 1*77.477/2.6728007/2.471.14476     
Shet land3*1/0AWG+ 1*123.37/3.37446019/ 1.891.52768     
Thoroughbred3*2/0AWG+ 1*155.47/3.78539019/2.131.52945     
Trotter3*2/0AWG+ 1*195.77/4.25679019/2.391.521166     
Walking3*4/0AWG+ 1*246.97/4.77856019/2.681.521442     
            
Executive Standard:NFC    
            
 Nom inal  Average diameter of Average                 insulation thickness    
 cross-section aeraWire number in ConductorMax resistance at 20conductorRated Strength    
Descriptionmm 2No.Ohm /k mMin(m m )Max(m m )KNm m    
PHASE, NEUTRAL,and PUBLIC HIGHTING1671.914.65.11.91.2    
2571.25.86.3 1.4    
3570.8686.87.3 1.6    
5070.6417.98.4 1.6    
70120.4439.710.2 1.8    
95190.321112 1.8    
120190.2531213.1 1.8    
150190.20613.915 1.7    
PORTER54.670.639.29.6 1.6    
7070.51010.2 1.5    
95190.34312.212.927.51.6    
            
Executive Standard:IEC1    
PhasePhasePhase Max. D.C.    
AAC+UV-XLPECompact ConductorUV-XLPE InsulationApprox.Overall Diam eterRes is tance of Conductor at 20ºC    
No.X Norm al Cross Section of CoresNo.of Al WiresOverall DiameterNormal ThicknessMin.Diameter      
No. X m m 2-m mm mm mm mm mohm /k m    
1 X 107/1.354.0510.86.056.053.08    
1 X 167/1.704.81.20.987.27.21.91    
1 X 257/2.2461.20.988.48.41.2    
1 X 357/2.5871.41.169.89.80.868    
1 X 507/3.008.31.41.1611.111.10.641    
1 X 7019/2.159.81.41.1612.612.60.443    
1 X 9519/2.5811.61.61.3414.814.80.32    
1 X 12018/3.00131.61.3416.216.20.253    
1 X 15030/2.5814.61.81.5218.218.20.206    
1 X 18536/2.5816.221.720.220.20.164    
1 X 24036/3.0018.42.21.8822.822.80.125    
2 X 107/1.354.0510.86.0512.13.08    
2 X 167/1.704.81.20.987.214.41.91    
2 X 257/2.2461.20.988.416.81.2    
2 X 357/2.5871.41.169.819.60.868    
2 X 507/3.008.31.41.1611.122.20.641    
2 X 7019/2.159.81.41.1612.625.20.443    
2 X 9519/2.5811.61.61.3414.829.60.32    
2 X 12018/3.00131.61.3416.232.40.253    
2 X 15030/2.5814.61.81.5218.236.40.206    
2 X 18536/2.5816.221.720.240.40.164    
2 X 24036/3.0018.42.21.8822.845.60.125    
3 X 107/1.354.0510.86.0513.073.08    
3 X 167/1.704.81.20.987.215.551.91    
3 X 257/2.2461.20.988.418.141.2    
3 X 357/2.5871.41.169.821.170.868    
3 X 507/3.008.31.41.1611.123.980.641    
3 X 7019/2.159.81.41.1612.627.220.443    
3 X 9519/2.5811.61.61.3414.831.970.32    
3 X 12018/3.00131.61.3416.234.990.253    
3 X 15030/2.5814.61.81.5218.239.310.206    
3 X 18536/2.5816.221.720.243.630.164    
3 X 24036/3.0018.42.21.8822.849.250.125    
4 X 107/1.354.0510.86.0514.643.08    
4 X 167/1.704.81.20.987.217.421.91    
4 X 257/2.2461.20.988.420.331.2    
4 X 357/2.5871.41.169.823.720.868    
4 X 507/3.008.31.41.1611.126.860.641    
4 X 7019/2.159.81.41.1612.630.490.443    
4 X 9519/2.5811.61.61.3414.835.820.32    
4 X 12018/3.00131.61.3416.239.20.253    
4 X 15030/2.5814.61.81.5218.244.040.206    
4 X 18536/2.5816.221.720.248.880.164    
4 X 24036/3.0018.42.21.8822.855.180.125    
            
Executive Standard:IEC2   
PhaseNeutralPhaseNeutral Max. D.C.  
AAC+UV-XLPEAAACCompact ConductorUV-XLPE Ins ulationConductor Resistance of Conductor at 20ºC  
No.X Norm al Cr os sNo.X Norm al Cross     Approx. Overall Diam eter    
Section of CoresSection of CoresNo.of Al.WireOverall Dia.Norm al Thick nessMin.No./Dia. of Al Alloy Wire PhaseNeutral  
No. X m m 2No. X m m 2-m mm mMin.No./m mm mohm /k mohm /k m  
1 X 161 X 167/1.704.81.20.987/1.7012.31.912.217  
1 X 251 X 257/2.2461.20.987/2.1014.71.21.393  
1 X 351 X 357/2.5871.41.167/2.5017.30.8681.007  
1 X 501 X 507/3.008.31.41.167/3.0020.10.6410.744  
1 X 701 X 7019/2.159.81.41.167/3.5023.10.4430.514  
1 X 951 X 9519/2.5811.61.61.3419/2.5027.30.320.371  
1 X 1201 X 12018/3.00131.61.3419/2.8030.20.2530.294  
1 X 1501 X 15030/2.5814.61.81.5237/2.2533.950.2060.239  
1 X 1851 X 18536/2.5816.221.737/2.5037.70.1640.19  
1 X 2401 X 24036/3.0018.42.21.8861/2.2543.050.1250.145  
2 X 161 X 167/1.704.81.20.987/1.7014.041.912.217  
2 X 251 X 257/2.2461.20.987/2.1016.631.21.393  
2 X 351 X 357/2.5871.41.167/2.5019.510.8681.007  
2 X 501 X 507/3.008.31.41.167/3.0022.460.6410.744  
2 X 701 X 7019/2.159.81.41.167/3.5025.70.4430.514  
2 X 951 X 9519/2.5811.61.61.3419/2.5030.310.320.371  
2 X 1201 X 12018/3.00131.61.3419/2.8033.410.2530.294  
2 X 1501 X 15030/2.5814.61.81.5237/2.2537.550.2060.239  
2 X 1851 X 18536/2.5816.221.737/2.5041.690.1640.19  
2 X 2401 X 24036/3.0018.42.21.8861/2.2547.410.1250.145  
3 X 161 X 167/1.704.81.20.987/1.7016.151.912.217  
3 X 251 X 257/2.2461.20.987/2.1019.061.21.393  
3 X 351 X 357/2.5871.41.167/2.5022.320.8681.007  
3 X 501 X 507/3.008.31.41.167/3.0025.590.6410.744  
3 X 701 X 7019/2.159.81.41.167/3.5029.220.4430.514  
3 X 951 X 9519/2.5811.61.61.3419/2.5034.420.320.371  
3 X 1201 X 12018/3.00131.61.3419/2.8037.870.2530.294  
3 X 1501 X 15030/2.5814.61.81.5237/2.2542.560.2060.239  
3 X 1851 X 18536/2.5816.221.737/2.5047.250.1640.19  
3 X 2401 X 24036/3.0018.42.21.8861/2.2553.630.1250.145  
            
Executive Standard:IEC3           
PhaseNeutralService ConnectionPhaseNeutralService Connection 
Approx. Overall
Diameter of Bundled Cable
AAC+UV-XLPEAAAC+UV-XLPEAAC+UV-XLPEConductorUV-XLPEConductorUV-XLPECompact ConductorUV-XLPE 
No.X Normal CrossNo.X Normal CrossNo.X Normal Cross  Normal Normal  Normal 
Section of CoresSection of CoresSection of CoresNo. of Al. WireOverall Dia.No./Dia. of Al. WireNo. of Al. WireOverall Dia.
            
ThicknessThicknessThickness
No. X mm2No. X mm2No. X mm2-mmmmmmmmNo./mmmmmmmm
3 X 161 X 501 X 167/1.704.81.27/3.01.47/1.704.81.226.2
3 X 251 X 501 X 167/2.2461.27/3.01.47/1.704.81.228.6
3 X 351 X 501 X 167/2.5871.47/3.01.47/1.704.81.231.4
3 X 501 X 501 X 167/3.008.31.47/3.01.47/1.704.81.234
3 X 701 X 501 X 1619/2.159.81.47/3.01.47/1.704.81.237
3 X 951 X 501 X 1619/2.5811.61.67/3.01.47/1.704.81.241.4
3 X 1201 X 501 X 1618/3.00131.67/3.01.47/1.704.81.244.2
3 X 161 X 502 X 167/1.704.81.27/3.01.47/1.704.81.226.2
3 X 251 X 502 X 167/2.2461.27/3.01.47/1.704.81.228.6
3 X 351 X 502 X 167/2.5871.47/3.01.47/1.704.81.231.4
3 X 501 X 502 X 167/3.008.31.47/3.01.47/1.704.81.234
3 X 701 X 502 X 1619/2.159.81.47/3.01.47/1.704.81.237
3 X 951 X 502 X 1619/2.5811.61.67/3.01.47/1.704.81.241.4
3 X 1201 X 502 X 1618/3.00131.67/3.01.47/1.704.81.244.2
Company Profile

Packaging & Shipping


Detailed Photos

Our Customer

FAQ

1.Are you a manufacturer or trading company?
We are a professional manufacturer. We can control your order from the first begining to the last. 
Welcome to visit us. We'll pick you up in Beijing or Shijiazhuang Airport.

2. How can I get a sample to test your quality?
The samples are free, Customers should pay for the courier. Courier charge can be deducted from your order amount.

 3. What's your Minimum Order Quantity?
MOQ: 100meter. 

4. Can I get a discount?
Discount can be negotiated when we talked about the order. Anyway we will try our best to provide you the best quality with better price and best shipping rate.

Product Tag:
Related categories:
Scroll to Top