Model | T-50A | T-50B |
Output | DC Voltage | Ch1:5v | Ch2:12v | Ch1:-5v | Ch2:5v | Ch1:12v | Ch2:12v |
Voltage tolerance | ±2.0% | ±6.0% | ±6.0% | ±2.0% | ±6.0% | ±6.0% |
Rated Current | 0.5-7A | 0.2-1A | 0-1A | 0.5-7A | 0.2-1A | 0-1A |
Related Power | 50w | 50w |
Wave&Noise | 80mVp-p | 120mVp-p | 80mVp-p | 150mVp-p | 120mVp-p | 150mVp-p |
DC Voltage ADJ range | Ch1:-9%~+10% |
Set up,rise,hold up time | 200ms 100ms 30ms |
Input | Voltage Range | 95 ~132VAC 180-264VAC 47-63HZ 120-370VDC |
AC Current | 1.6A/115VAC 0.8A/230VAC |
Efficiency | 72% | 72% |
AC inrush current | Cold start current 20A/115V 40A /230VAC |
Leakage current | <3.5mA/240VAC |
Protection | Overload | Related output power 105-150% start overload protection |
Protection type: cutoff output, recovery after restart power |
Over voltage | Ch2 :115%~135% |
Hiccup mode,recovers automatically after fault condition |
Environment | Working temp humidity | -10~+60°C 20%~90%RH |
Storage temp, humidity | -20~+85°C 20%~90%RH Non-condensing |
Withstand vibration | 10-500Hz,2G 10min/1 cycle, period for 60min, each axes |
Safety | Withstand voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
Isolation resistance | I/P-O/P:I/P-FG:O/P-FG: 100M Ohms/500VDC |
Standard | Safety standard | Fit UL1012 |
Refer | Design refer to GB4943,UL60950,EN60950 |
EMC standard | Design refer to GB9254,EN55022 Class A |
Size | size | L159*W98*H38mm |
Package | 0.54kg, 40pcs/22kg |
Note:1.All parameters not specially mentioned are measured at 230VAC input, related load and 25 degree of ambient temperature. |
2.Wave&noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf&47uf parallel capacitor. |
3.Tolerance: includes set up tolerance, line regulation and load regulation. |