Dcu10 Color Doppler Ultrasound Scanner with Internal Battery

Min.Order: 3
Product origin: Xuzhou, Jiangsu, China
Infringement complaint: complaintComplaint
US$ 2 ~ 5000

Description

DCU10 COLOR DOPPLER SYSTEMS 

1. Instructions for use
For the examine of abdomen, heart, gynecology, obstetrics, urology, small organs, pediatrics, blood vessels, etc.


2. Monitor
High resolution 15 "LCD display.

3. Image display mode
B,2B,B+M,4B,M,B+Color,B+PDI,B+PW,B+Color+PW,B+PDI+PW,★B+C/PDI Double real time

4. Probe elements: 128
High resolution 15 inch LCD display
 
5. Full Digital Imaging Technology
Pulse inverse harmonic composite imaging
Multi-beam synthesis
Space compound
Image enhancement noise reduction

6. Imaging mode
B mode
M mode
Color (Color Doppler ) mode
PDI (Energy Doppler)mode
PW (Pulse Doppler)mode


7. Image display mode
B,2B,B+M,4B,M,B+Color,B+PDI,B+PW,B+Color+PW,B+PDI+PW, B+C/ PDI double real time

8. Supported probes
Convex probe3.5MHz convex probe
Linear probe7.5MHz linear probe
Cavity probe6.5MHz linear rectal probe
Micro-convex probe6.5MHz micro-convex probe
Probe frequency:2.5-10.0MHz
Probe socket:Probe socket: 2 PC

9. System language

Chinese / English/Spanish operating system and language environment, support other languages according to user requirement;

Full screen annotation input, Chinese/ English; Chinese input methods ≥2,including Wubi input method


10. Measurement calculation software package

Abdomen, gynecology, obstetrics, small organs, heart, blood vessels, etc.

11. Image parameters

B mode1.   Gray scale mapping:≥15
2.   Noise suppression:≥8
3.   Frame correlation:≥8
4.   Edge enhancement:≥8
5.   Image enhancement:≥5
6.  Space compound: Switch adjustable
7.  Scan density: High, middle, low
8.  Image flip: Up, Down, Left, Right
9.  Maximum scanning depth:≥320mm
M mode1. Scan speed(SweepSleep):≥5adjustable
2. Line average(LineAverage):8
PW mode1. SV size / location: SV size1.0-8.0mm , adjustable
2. PRF:≥16 ,0.7kHz-9.3KHz  
3. Scan speed(SweepSleep):≥5, adjustable
4. Correction angle(CorrectionAngle):-85°~85°,step length5°
5. Spectrum flip:Switch adjustable
6. Wall Filter:≥4, adjustable
7. Doppler sound:≥20, adjustable
 
Color/PDI mode1. PRF:≥15 ,0.6KHz -11.7KHz
2. Color map(color map)≥4 kinds
3. 
Color related:≥8
4. 
post-treatment:≥4

12. Measurement and calculation

1. B/C mode routine measurement: Distance, area, perimeter, volume, angle, area ratio, distance ratio

2. M mode routine measurement: time, slope, heart rate, distance

3. Doppler mode routine measurements: heart rate, velocity, velocity ratio, resistance index, pulse index, manual / automatic envelope, acceleration, time

4. Obstetrics B, PW  mode application measurements: EDD and GA for bovine, equine, ovine, canine, feline, goat,swine and llama and OB report generation..

5. Heart B,M mode application measurements

6. Blood vessels PW mode application measurements

7. Small organ B mode application measurements

8. Abdomen B mode application measurements

13. Standard configuration

1.   Main unit
2.   High-resolution 15-inch LCD monitor
3.    6.5MHz micro-convex probe:1  pc
4.   7.5MHz linear probe:  1 pc
5.   Inverse harmonic imaging technique
6.   PDI(Energy Doppler mode)
7.   Spatial composite imaging
8.   Built-in workstation