1MW Natural Gas Power Generator Set

Min.Order: 1
Product origin: Qingdao, Shandong, China
Infringement complaint: complaintComplaint
US$ 654400

Description
1MW Natural Gas Power Generator Set




. Focused on special automobiles' design and production for nearly 10 years.
. Obtained the ISO9001 international quality management system certification.
. Achieved foreign trade qualification granted by Chinese government.
. Manufacturer direct sale,quality guaranteed, low price.
. Europe Emission Standard 2/3/4/5.
. Except standard products, also customize products according to your requirements.

Parameters

According to the overall planning of the project, 2 natural gas generator sets with single power 1000kW (400V/50Hz) will be installed in this project, the genset is equipped with intake system, cooling system, exhaust system, electrical system, starting system and other auxiliary production systems. The generator set is operated under isolated moel.

Technical parameters of main equipment

1.Technical specification of natural gas generator set
 ItemSpecification
Gas engineType8300ZLD/T-1
StyleInline, water cooled, four stroke, spark plug ignition, open combustion chamber
Cylinder number8
Cylinder diameter (mm)300
Piston total Displacement (L)215
Piston stroke (mm)380
Rated speed (r/min)600
Rated power (kW)1100
Rated thermal consumption (MJ/kW·h)≤9.5
Rotation direction (viewed from flywheel)Clockwise
Starting methodCompressed air/motor start
Exhaust temperature (ºC)≤650
Gas pressure (kPa)≥2.5
Gas temperature (ºC)≤40
Oil consumption(g/kW·h)≤1.0
 Generator setType1000GFT
Rated power (kW)1000
Rated voltage (V)400
Rated current (A)1804
Power factor (COSΦ)0.8 Lagging
Excitation mode Brushless
Phases and connection3-phases 4-wire
Stationary voltage regulation ratio (%)±2.5
Instant voltage regulation ratio (%)±20
Voltage stable time (s)≤5
Voltage fluctuation ratio (%)≤1
Stationary frequency regulation ratio (%)≤5(0~5Adjustable)
Instant frequency regulation ratio (%)-20~+12
Frequency stable time (s)≤10
Dimension (L×W×H) (mm)6400×1600×2900
Weight (kg)25000

2.Operation conditions of gas generator set
2.1 Environment requirement
Generator set can run stably, reliable and continuously under environment conditions: ambient temperature -20ºC~40ºC, relative humidity ≤90%(20ºC), height above sea level≤1000m.
   Generator set can output stably rated power under standard condition:
ambient pressure 100kPa, ambient temperature 25ºC, air relative humidity 30%.
2.2 Gas requirement
Normally, natural gas temperature≤40ºC, gas pressure 2.5~10kpa, pressure change rate≤1kPa/min, concentration change rate≤2%/min, impurity size≤5μm, impurity content≤30mg/Nm3, water content≤40g/Nm3,no free water, H2S≤200mg/Nm3, NH3≤20mg/Nm3

Engineering design

According to project actual situation and need of power plant site, power plant layout is necessary to meet the technical requirements, to meet the safety requirements of fire and explosion prevention, also to create a good production and living environment. There are gas generator set room, low-voltage power distribution room and pumping station in the plant. Width not less than 4m ring fire truck road should be designed around gas generator set room. Power distribution cabinet and low voltage cabinet are placed in low-voltage power distribution room; compressor and air bottles are placed in pumping station.
1.Gas intake system
Natural gas flow into gas generator set through gas main pipe, branch pipe and butterfly valve. In order to ensure the normal operation of gas generator set, butterfly valve, emergency cut-off solenoid valve and fire arrestor are installed on the gas pipeline, to realize the protection of the unit and the automatic control of gas inlet.
2.Cooling system
2.1 Design range
The cooling circulation includes: gas generator set cooling water circulation system and inner water filling system. The main equipment is the cooling tower, pump,etc.
3.Exhaust system
Exhaust gas temperature of natural gas generator set ≤650 ºC, the exhaust system is equipped with expansion joints, muffler and other equipment. With SCR on the roof.
4.Electrical system
4.1System Overview
Each natural gas generator set is equipped with 1 by-pass control cabinet and 1 Low-voltage switchgear, by-pass control cabinet field monitoring and display genset operating parameters, transmits alarm signal to the Low-voltage switchgear generator set voltage 400V, electricity generated transmitted and controlled by Low-voltage switchgear. With over-current, reverse power, over voltage, overload, under voltage protection, meanwhile control genset switch-closing, switch-opening, parallel, active power regulation and reactive power regulation.
4.2 Generator set safety control system
Gas generator set in accordance with Common Technical Requirements for Gas Fuel Generator Set, and has the following safety devices:
1, Low oil pressure alarm, too low oil pressure stop.
2, Over speed alarm and engine stop.
3, cooling water temperature alarm.
4, High lubricating oil temperature alarm
5, Generator reserve power protection
6, Generator under voltage, over voltage protection
7, Generator over current protection
8, Generator low frequency, over frequency protection
5.Starting system
Natural gas generator set using compressed air start, starting system mainly include air compressor and air bottle.





Our Service

1.. Reply your inquiry in 12 working hours;
2. Experienced staffs answer all your questions;
3. Customer's design is available for certain products(OEM);
4. Spare parts for all types of engine machinery with reasonable price;
5. Different brand of trucks can be provided with competitive price.

Contact Person
FRANK XIANG

 

Scroll to Top