Rdcps2 LCD Display Overload Protection Control Switch

Min.Order: 1
Product origin: Wenzhou, Zhejiang, China
Infringement complaint: complaintComplaint
US$ 130 ~ 150

Description
LCD Display Overload Protection Motor Speed Control Switch Circuit Breaker (RDCPS2)










Overview

RDCPS2 control and protective switch is mainly applied to low-voltage power distribution and motor control and protection circuits. Rated working voltage 690V and below, AC 50/60Hz, rated working current 0.15A ~ 125A.
RDCPS2 is a high-end product with optimized structure, compact, energy-saving, environmentally environmental friendly materials, easy installation and operation; intelligent digital controlsystem, reliable protection, and communication interface, it secure automatic control systems and remote control systems.
RDCPS2 is a all-in-one switching device with circuit overload, short circuit protection functions, high breaking capacity; it is able to making and breaking the load, long service life, secure and has isolation functions; simplify low-voltage control circuit, improve the reliability of the automation control system, providing a reliable basic component for low-voltage power distribution and motor control circuits.
RDCPS2 is subject to IEC60947-1, EC60947-6-2 standards.
The materials used in this product comply with the requirements of the ROHS Directive (lead Pb, mercury Hg, cadmium Cd, hexavalent chromium Cr, polybrominated biphenyl PBBs, polybrominated diphenyl ether PBTEs, etc.)


Working Conditions
Standard Working Environment
Ambient temperature:from -15ºC to+40ºC,24h average temperature ≤ +35ºC;
Installation altitude: ≤ 2000m;
Installation environment humidity:When the maximum temperature is +40 °C, the relative humidity of the air does not exceed 50%, higher relative humidity is allowed at lower temperatures, for example, 90% at +20 °C, for temperature changes Special measures should be taken for occasional condensation ;
Environmental pollution level: Class 3;
Protection level: IP20;
Applicable electromagnetic environment: Class A
WARNING: This product is intended for use in Environment A. Use of this product in Environment B can cause harmful electromagnetic interference, in which case the user must take appropriate precautions.
Storage and transportation conditions
Storage and transportation environment of the product should be cool and ventilated. There should be no direct sunlight, rain forest, dust, chemical gas corrosion, etc. The applicable ambient temperature range is -25°C~ +55°C, and it can reach +70°C in a short time (24h);
Installation conditions
Main circuit overvoltage category of this switch is applicable to III (distribution level), and the auxiliary circuit and control circuit overvoltage category is applicable to II (load level).


Utilization Category
 
RDCPS2 control and protective switch applies to below load circuits.
CircuitUtilization CategoryApplication
Main CircuitAC-20Making/breaking without load
AC-40Distribution circuit, including mixed resistivity and inductive load
AC-41AC-42No-inductive or micro inductive load, resistor furnace
AC-42Slip ring type motor: start, breaking
AC-43Cage type inductive motor: start, breaking during running
AC-44Cage type inductive motor: start, reverse connect stop or reverse
running, point moving.
AC-45aDischarge lamp ON/OFF
AC-45bFilament lamp ON/OFF
Auxiliary CircuitAC-15Control AC electric magnet
DC-13Control DC electric magnet load

Technical Data
Main technical datas (main circuits)
Frame size63125
Rated working voltage Ue400VAC/690VAC(220VAC custom design)
Rated isolation voltage Ui690V800V
Rated withstand voltage Uimp6kV8kV
Conventional thermal current Ith(A)12326380125
Rated working current Ie(A)0.6, 1.2, 2.4,6,1218, 3245,6380125
Rated frequency50Hz(60Hz custom design)
Rated operational system (Intermittent duty)300120
Rated short-circuit breaking capacity IcsAC400V50kA50kA
AC690V4kA6kA
Utilization CategoryAC-43
Breaking action time≤ 2ms
Number of poles3
Main technical datas(Rated working current and control power)
Frame sizeConventional thermal current Ie(A)Rated working
current Ie(A)
Overload current
setting range Ir1(A)
Controllable motor power Pe(kW)
220VAC400VAC690VAC
63120.60.15-0.60.04-0.180.01-0.180.07-0.3
1.20.3-1.20.06-0.180.07-0.50.13-0.86
2.40.6-2.40.09-0.550.15-1.00.25-1.8
61.5-60.25-1.50.52-2.80.9-5.0
123-120.75-31.1-62.0-10
32187.2-181.5-43.0-9.55.0-16
3212-323-7.55.0-16.58.5-29
634518-454-117.1-23.514-43
6325-635.5-18.510-3519-60
125808045-8011-2220-4536-76
12512563-12519.5-3728-5551-110
 
Main technical datas(control and auxiliary circuit)
 Frame size rated working current Inm(A)63125
Control CircuitControl voltage Us(V)230VAC 50Hz(60Hz custom design)
Electromagnet coil's Max. power consumption(W)47
Electromagnet coil's action time(ms)making: less than 80, breaking: less than 70
Mechanical life (cycles)10 milion3 milion
Electrical life(AC-43) ( cycles)1 milion300,000
Operation frequency(on-load factor 40%)600600
Auxiliary switch circuitNumber of contacts2NO + 2NC2NO + 2NC
Contact capacityAC-15230VAC, 5A
DC-13( DC110V,.0.55A), (DC24V, 5A)
Ui:250V,Uimp:4kV,Ith:5A
Auxiliary status circuitNumber of contacts2NO + 1NC2NO + 1NC
Ue:230VAC ,Ui:250V,Uimp:4kV,Ith:5A
Controller alarm circuitNumber of output contacts1NO1NO
Ue:230VAC ,Ui:250V,Uimp:4kV,Ith:5A
Communication circuit moduleUe:24VDC ,Ui:24V,Uimp:0.8kV


 

Dlivery Terms
Shipment & Express & Air express






Packing





About the Company












We've got CE, TUV, KEMA, CCC certificate for ATS which also meets the ISO9001 standard and the factory has go through SGS test. 

FAQ: 
1. What's the warranty term? 
24 Monthes. 
2. How long does it take to deliver my goods? 
Normally, samples can be delivered in 2 days. Customer designed sampleswill be delivered in 3-7 days. 
3. Do you offer sample? 
Yes, we offer sample order for customer to test the goods. 
4. What kinds of payment terms do you accept? 
We offer kinds of payment ways foe customer to chose from. T/T, L/C, Western union etc. 
5. What if there's quality peoblem? 
We offer replacement for the goods as soon as there is a quality problem with the goods, and the fright is on our account to cut down the customer's loss to the lowest. 

We are sure any of your questions will get our prompt reply, just leave the message! 
Product Tag:
Related categories:
Scroll to Top