Description
Quick DetailsPlace of Origin: China (Mainland) Brand Name: XINCHENG
Product name: analog panel meter voltage meter AC DC ammeter/voltmeter
Application: Voltage Measuring Instrument AC Pointer Gauge Analog Voltmeter
type: Pointer type DC Ac voltmeter pointer type voltage measuring instrument
Usage: Industrial Measurement
Model Number: 48,72,91C4V etc. Display Type: Analog Only
Measuring Range: 0-600V or According to Customer Accuracy Class: 1.5, 2.5 as customized
Dimensions: 45*45 96*96mm etc. or customized Certificate: CE PSE RoHS SGS ISO9001
Service: OEM ODM
Color: White\Black or According to Customer Operating Temperature: -35-55
ºCPointer Material: Cu/Al Inner connection Line: UL line
Screw: Cu HS Code: 90308990
Base material: ABS/PC/Bakelite Case material: PC/PMM
Moving Coil: Fuji Line Soldering: ROHS solde wire
Phase: Single/three Phase Frequency: 45~65Hz or According to Customer
Product DescriptionThis series of meter is a direct imitation of power measurement display instruments, measuring DC current and voltage, AC current and voltage, frequency, power factor, phase sequence, power, synchronization instructions and other non-power measurement.it has been widely used in a variety of AC and DC transmission and distribution systems, power control panels and other electrical devices, in the industries of maritime shipping, rail transport, chemical flameproof, low voltage equipment, construction equipment, generators, machinery equipment, etc. Being able to make electrical measurement and ono-power measurement, it is a high-end instrument applied in general environmental conditions.
The conventional overload multiple times, should be once or twice, and it can be customized to once,twice,3 times and so on according to the user requirements. its function is to indicate the approximate transient overload current value, such as the start-up current when the motor stars ,and so on.
The base of the series of our products are made of TBT flame-retardant plastic, and its vicat temperature is 130
ºC.the outer shell is made of ABS flame-retardant plastic, and its vicat temperature is 85
ºC.
The surface of the dial uses aluminum alloy, white paint, black ink printing or laser printing. The dial can be customized according to the customer sample dials(overprint colors can be customized).the luminous dial uses the PC panel.
This series of meters is a direct imitation of power measurement display instruments, measuring DC current and voltage, AC current and voltage, frequency, power factor, phase sequence, power, synchronization instructions and other non-power measurements. It has been widely used in a variety of AC and DC transmission and distribution systems, power control panels and other electrical devices, in the industries of maritime shipping, rail transport, chemical flameproof, low voltage equipment, construction equipment, generators, machinery equipment, etc. Being able to make electrical measurement and non-power measurement, it is a high-end instrument applied in general environmental conditions.
Standards and certifications:
Our product of pointer meter is produced on the standard of GB/T7676-1998, and the digital meter is on the standard of GB/T22264-2008. Its safety performance is on the standard of GB4793 and IEC61010. The dial scale line and the pointer is designed to meet the German standards of DIN43790 and DIN43802. The shape and hole size of the meter is on the standards of GB/T1242 and IEC61554. All the products of our Company have gone through the national CE certification, and have got ISO: 9001 certification.
The outer casing of the panel meter:
The base of the series of JY meters is made of TBT flame-retardant plastic, and its vicat temperature is 130°C. The outer shell is made of ABS flame-retardant plastic, and its vicat temperature is 85°C.
Changes caused by the temperature:
Temperature range for reference: 23°C±2°C, 13°C~23°C, and 23°C~33°C. The changes caused by the impact of temperature are not allowed to be out of the range of the level index ±100%.
The installation:
Unless specified, the meter is usually installed in a vertical position. Other installation positions such as horizontal and inclined position can be installed according to the customer's requirements. The corresponding level of accuracy is only valid to the regulated installation position. The meter has two kinds of instruction angles: right angle 90°and wide angle 250°.
Anti-vibration and anti-shock:
Anti-vibration: complies with the standard of IEC60068-2-6; frequency sweep range: 10-55-10Hz; displacement amplitude: ±0.15mm, ±0.3mm; frequency sweep cycles: 5 times; sweep rate: 10ct/min; maximum acceleration: 147m/s2(15g), 490m/s2(50g); RMS acceleration: 6.06g;vibration time: 15 min. Anti mechanical shock: complies with the standard of IEC60068-2-27.
Accuracy level:
The JY series of pointer meter: AC and DC voltmeter and ammeter to the level of 1.5 or 2.5, power meter to the level of 2.5, frequency meter to the level of 2.5, and power factor meter to the level of 2.5.
Overload ammeter:
The conventional overload multiple times should be once or twice, and it can be customized to once, twice, 3 times and so on according to the user's requirements. Its function is to indicate the approximate transient overload current value, such as the start-up current when the motor stars, and so on.
Extrinsic current shunt:
The voltage specifications of the extrinsic current shunt of DC ammeters are 150mV,100mV,75mV,60mV and 50mV, which can be customized. The resistance of the conducting wire connecting the meter and the current shunt should within the range of 15
∼25mΩ, to ensure the accuracy of the meter.
The surface of the dial:
The surface of the dial uses aluminum alloy, white paint, black ink printing or laser printing. The dial can be customized according to the customer's sample dials (overprint colors can be customized). The luminous dial uses the PC panel.
Zero regulator:
Except the reading meters without mechanical zero, all other meters have pre-positive zero regulator, used to adjust the meter's mechanical zero.
Product composition:PC Front and Bakelite case, Four stud mounting,
Scale Plate:
The normal scale plate is made of alloy-aluminium material white printed with black scales,Values, units, technique symbols, etc.
Scale plate with special requirements are available upon request.
Such as color, scale with lighting functions and PVC noctilucence are available upon request.
Pointer:
Normally, the pointer is made of alloy-aluminum, it is black, and red, white are available Upon request.
Anti-static:
All meters are subject to anti-static treatment to minimize the static-effect to the accuracy of the meters.
Damping and Overshoot:
The overshoot is less than 15% when the pointer is at the 2/3 of the scale.
Damping and overshoot can be customized according to user's requirements.
Operating position:
Generally, meter is installed in vertical position. Other installation position can be customized (please specify the desired angle).The accuracy class is just valid for the Corresponding installation mode.
Insulation Test:
The test Voltage for BE&BP series is 2KV RMS for 1 minute with the frequency 50Hz.
Safety Precautions:
Meters with damaged bezels or glass faceplates must be disconnected from the mains. Scale plate, front frames and windows may only be replaced under voltage-free conditions.
The meter should be kept clean, if the meter is used in a manner not specified by the manufacturer, the protective function may be impaired.
Model | | BP-80 | BP-60 | BP-670 | BP-45 |
Front frame | mm | 80*80 | 60*60 | 60*70 | 50*50 |
Panel cutout | mm | 64 | 52 | 53 | 45.5 |
AC current |
Ranges | mA | 100mA -800mA |
A | 1A 5A 10A 15A 20A 25A 30A 40A 50A 60A |
Combined with an external C.T. | X/1A | 10/1A - 3000/1A More Ranges can be customized |
X/5A | 10/5A - 3000/5A More Ranges can be customized |
The common type is no overload,1.5 2.0 3.0 5.0 6.0 times overload can be customized |
AC voltage |
Ranges | V | 10V 25V 40V 50V 60V 100V 150V 250V 300V 450V 500V |
KV | Combined with an external PT **/100V **/110V **/120V |
Mini Square Type Voltage Measuring Instrument AC Pointer Gauge Analog Voltmeter More Technical Data:Name | Precision | Normal Specification | Remark |
AC Ammeter | A | 1.5 | 0.5-50A | Can be directly connected |
A | 1.5 | 10/5A-800/5A | Secondary current passed by current transformer |
KA | 1.5 | 1KA-10KA | Secondary current passed by current transformer |
AC Voltmeter | V | 1.5 | 10V-600V | Can be directly connected |
KV | 1.5 | 1KV-35KV | 100V secondary voltage passed by voltage transformer |
DC Ammeter | µA mA | 2.5 | 50µA-500µA 1mA-500mA | Can be directly connected |
A | 1.5 | 1A-15A | Can be directly connected |
A | 1.5 | 15A-750A | Outer attached shunt 75mV 60mV 50mV |
KA | 1.5 | 1KA-3KA | Outer attached shunt 75mV 60mV 50mV |
DC Voltmeter | V | 1.5 | 3V-600V | Can be directly connected |
KV | 1.5 | 1KV-3KV | Outer attached resistance value |
Power meter | KW.VAR | 2.5 | 100V 380V 380-380KV | 100V secondary voltage passed by voltage ; Secondary current passed by current transformer 5-10KA/5A |
Hz meter | Hz | 2.5 | 45-55HZ 55-65HZ | 36V.100V.127V.220V.380V |
Feature1. Should be used in the temperature range: -20~55°C, humidity: ≤80%, to prevent undesirable phenomena caused by temperature changes.
2. Take care of vibration and shock
3. Do not use it in places with dust, gas and chemicals harmful for electrical products.
4. If the abnormal voltage is caused by the magnetic field, high frequency devices, high voltage spark, lightning and etc, please use the external power line filter or non-linear resistors to interfere and absorb the circuit.
5. The signal input line should be as short as possible, and protective shielding wire should be used in places where there may be interfering signals.
outline and installation dimensions & wiring scheme
FAQQ1. Can I have a sample order for panel meter?A: Yes, we welcome sample order to test and check quality. Mixed samples are acceptable.
Q2. What about the lead time?A:Sample needs 3-5 days, mass production time needs 20 days to 30 days for order quantity more than .
Q3. Do you have any MOQ limit for panel meter order?A: Low MOQ, 1pc for sample checking is available
Q4. How do you ship the goods and how long does it take to arrive?A: We usually ship by DHL, UPS, FedEx or TNT. It usually takes 3-5 days to arrive. Airline and sea shipping also optional.
Q5. How to proceed an order for panel meter?A: Firstly let us know your requirements or application.
Secondly We quote according to your requirements or our suggestions.
Thirdly customer confirms the samples and places deposit for formal order.
Fourthly We arrange the production.
Q6. Is it OK to print my logo on panel meter product?A: Yes. Please inform us formally before our production and confirm the design firstly based on our sample.
Q7: Do you offer guarantee for the products?A: Yes, we offer 1~3 years warranty to our products.
Q8: How to deal with the faulty?A: Firstly, Our products are produced in strict quality control system and the defective rate will be less
than 0.2%.
Secondly, during the guarantee period, we will send new panel meters with new order for small quantity.
For defective batch products, we will repair them and resend them to you or we can discuss the solution including re-call according to real situation.
Packaging & DeliveryPackaging Details
In export carton with pallets
Delivery Time
Shipped in 20 days after payment
Our seivice:1.Professional person communicate with you before the order
2.OEM & ODM, also provide customized service
3.Distributer ship are offered for your unique design and some our current model
4.Protection of your sales area, ideas of design and all your private information
5.Provide strict quality check for each part,each process before export
6.Provide complete post-sale service,including installation,technical guide
Please Contact Us Miss: lydiaMob: 86-13752439076 Fax: 86-22-60863016 http://chinainsulation.en.made-in-china.com