Model | GDC250*S | ||
Phase | 3 Phase | ||
Power Factor | 0.8cosØ | ||
Frequency | 50HZ | ||
Speed | RPM | 1500 | |
Max. Power | KVA | 275 | |
KW | 220 | ||
Rated Power | KVA | 250 | |
KW | 200 | ||
Rated Voltage | V | 400 | |
Rated Current | A | 360 | |
Fuel Consumption | L/H | ≤ 57.5 | |
Generator Controller | Auto Multi-function | ||
Engine Model. | 6LTAA8.9G2 | ||
Alternator Model. | JDG 274K | ||
Clinder No. | 6/L | ||
Starting System | Electric Start | ||
Cooling Method | Water-cooling | ||
Protection Grade | IP23 | ||
Insulation Class | H | ||
Size (MM) | Silent Type | 3600*1330*2065 | |
Open Type | 2890*1050*1780 | ||
Optional | ATS (auto transfer switch) |
Quotation of Diesel Genset-CUMMINS Engine & GODLIKE Alternator and HGM6110 Control Panel | |||||
Item No | Genset Model | Power Out Put 400V/50HZ/1500RPM/3P/0.8 ( Y ) | Cummins Engine Model | Godlike Alternator Model | |
Prime 40 degree | |||||
1 | GDC23 | 18KW | 23KVA | 4B3.9G1/24KW | JDG 184E |
2 | GDC23 | 18KW | 23KVA | 4B3.9G2/24KW | JDG 184E |
3 | GDC28 | 22KW | 28KVA | 4B3.9G1/24KW | JDG 184F |
4 | GDC28 | 22KW | 28KVA | 4B3.9G2/24KW | JDG 184F |
5 | GDC31 | 25KW | 31KVA | 4BT3.9G1/36KW | JDG 184G |
6 | GDC31 | 25KW | 31KVA | 4BT3.9G2/36KW | JDG 184G |
7 | GDC40 | 32KW | 40KVA | 4BT3.9G1/36KW | JDG224C |
8 | GDC40 | 32KW | 40KVA | 4BT3.9G2/36KW | JDG 224C |
9 | GDC50 | 40KW | 50KVA | 4BTA3.9G2/50KW | JDG 224D |
10 | GDC56 | 45KW | 56KVA | 4BTA3.9G2/50KW | JDG 224ES |
11 | GDC60 | 48KW | 60KVA | 4BTA3.9G2/50KW | JDG 224E |
12 | GDC100 | 80KW | 100KVA | 6BT5.9G1/92KW | JDG 274C |
13 | GDC100 | 80KW | 100KVA | 6BT5.9G2/90KW | JDG 274C |
14 | GDC120 | 96KW | 120KVA | 6BTA5.9G2/106KW | JDG 274DS |
15 | GDC125 | 100KW | 125KVA | 6BTA5.9G2/106KW | JDG274D |
16 | GDC135 | 108KW | 135KVA | 6BTAA5.9G2 /120KW | JDG 274ES |
17 | GDC160 | 128KW | 160KVA | 6CTA8.3G2/163KW | JDG 274F |
18 | GDC180 | 144KW | 180KVA | 6CTA8.3G2/163KW | JDG 274G |
19 | GDC200 | 160KW | 200KVA | 6CTAA8.3G2/183KW | JDG 274H |
20 | GDC225 | 180KW | 225KVA | 6LTAA8.9G2/220KW | JDG 274J |
21 | GDC250 | 200KW | 250KVA | 6LTAA8.9G2/220KW | JDG 274K |
22 | GDC250 | 200KW | 250KVA | NT855-GA/231KW | JDG274K |
23 | GDC250 | 200KW | 250KVA | MTA11-G2A/234KW | JDG274K |
24 | GDC275 | 220KW | 275KVA | NTA855-G1A/261KW | JDG 314DS |
25 | GDC300 | 240KW | 300KVA | NTA855-G1A/261KW | JDG 314D |
26 | GDC313 | 250KW | 313KVA | NTA855-G1B/284KW | JDG 314ESS |
27 | GDC325 | 260KW | 325KVA | NTA855-G1B/284KW | JDG 314ES |
28 | GDC350 | 280KW | 350KVA | NTA855-G2A/313KW | JDG 314E |
29 | GDC350 | 280KW | 350KVA | NTA855-G4/317KW | JDG 314E |
30 | GDC375 | 300KW | 375KVA | NTAA855-G7/343KW | JDG 314FS |
31 | GDC375 | 300KW | 375KVA | KTA19-G2 /336KW | JDG 314FS |
32 | GDC400 | 320KW | 400KVA | NTAA855-G7A/407KW | JDG 314F |
33 | GDC450 | 360KW | 450KVA | KTA19-G3 /403KW | JDG 354C |
34 | GDC500 | 400KW | 500KVA | KTA19-G3A/448KW | JDG 354D |
35 | GDC500 | 400KW | 500KVA | KTA19-G4 /448KW | JDG 354D |
36 | GDC550 | 440KW | 550KVA | KTAA19-G5 /470KW | JDG 354ES |
37 | GDC575 | 460KW | 575KVA | KTAA19-G6/520KW | JDG 354E |
38 | GDC600 | 480KW | 600KVA | KTA19-G8/575KW | JDG 354E |
39 | GDC625 | 500KW | 625KVA | KTAA19-G6A /610KW | JDG 354FS |
40 | GDC625 | 500KW | 625KVA | KT38-G/560KW | JDG 354FS |
41 | GDC725 | 580KW | 725KVA | KT38-GA/711KW | JDG 354G |
42 | GDC750 | 600KW | 750KVA | KTA38-G2/664KW | JDG 404B |
43 | GDC800 | 640KW | 800KVA | KTA38-G2B/711KW | JDG 404C |
44 | GDC900 | 720KW | 900KVA | KTA38-G2A/813KW | JDG 404D |
45 | GDC1000 | 800KW | 1000KVA | KTA38-G5/880KW | JDG 404E |
46 | GDC1125 | 900KW | 1125KVA | KTA38-G9/1089KW | JDG 404F |
47 | GDC1250 | 1000KW | 1250KVA | KTA50-G3/1097KW | JDG 404G |