Fluorescence Spectrophotometer, 1nm /2nm /5nm /10nm /20nm, ± 0.4nm

Min.Order: 1
Product origin: Xiangtan, Hunan, China
Infringement complaint: complaintComplaint
US$ 19231 ~ 23077

Description
  1. Ultra-high signal noise ratio: unique horizontal beam design, large diameter concave grating monochromator optical system, excellent luminous efficiency and ultra-high detection signal to noise ratio, the water Raman peak signal noise ratio greater than 250:1(PP) or 800:1(RMS).
  2. Ultra-high scanning speed: world's highest speed wavelength scanning 60000nm/min, can be easily achieved to scan three-dimensional fluorescence spectra of samples within 1 minute.
  3. Ultra-high resolution: Multi-level bandwidth adjustable, excitation and emission spectra can achieve 1nm, 2nm, 5nm, 10nm and 20nm five-speed adjustment. 1nm spectral resolution can easily meet similar rare earth fluorescent materials and other special fluorescent substance spectrum differentiate needs.
  4. High wavelength accuracy: precision wavelength drive mechanism and intelligent wavelength calibration, wavelength accuracy of the instrument reach to the highest level in the same type of product.
  5. Super-rich set of advanced scanning capabilities: to achieve three-dimensional fluorescence scanning, three-dimensional time scanning, wavelength difference synchronous scanning, and constant energy differential synchronized scanning functions.
  6. Less sample volume needs: only need 0.5ml sample (in 10mm sample pool) to meet the test requirements.
  7. High quality assurance: xenon light source and a photomultiplier tube detector and other key components of the instrument are made of high quality Japanese Hamamatsu.
  8. Large sample chamber: Compared to the previous generation it has a large volume of sample room design, sample replacement and accessory adjustment work more easier, more comfortable experience with the instrument.
  9. Built-in optical gate device: built-in programmable optical gate device, designed for easy photo-reactive fluorescent signal instability or a sample survey design, unified sample excitation fluorescence detection rhythm improve the accuracy of analysis.
  10. kinds of measurement accessories include: hole sample cell holder, multi-fluorescent sample holder, 200μL microcentrifuge tube measurement accessories, capillary micro sample measurement accessories, semi-automatic sample injection fluorescence attachment hole sample cell adapter, film and powder samples accessories and sample measurement sheathed sample cell holder and other accessories, greatly expanded the scope of application of the instrument.

Specifications:
ModelSP-F98
Detection sensitivity (water Raman peak signal noise ratio) S/N ≥250 (P-P) or 800(RMS)
Excitation wavelength Bandwidth1nm/2nm/5nm/10nm/20nm
Emission wavelength Bandwidth1nm/2nm/5nm/10nm/20nm
Minimum sample volume0.5ml(using 10mm sample pool)
Wavelength accuracy±0.4nm
Wavelength repeatability≤0.2nm
Light source150W automatic deodorizing xenon lamp (Hamamatsu, Japan)
Optical systemDouble-grating monochromator automatic wavelength scanning with optical excitation double beam ratio monitoring
Fluorescence ReceiverOriginal photomultiplier (Hamamatsu, Japan)
Excitation wavelength range 200nm~900nm
Emission wavelength range 200nm~900nm
Wavelength scanning speed 10 positions, fastest 60000nm/min
Measurement line≥0.995
Gain adjustment range 1~17 position optional
Integral Response time 7 position options: 8s ~ 20ms
Data output Microsoft (R) Excel format, bmp image format
Data transmission USB2.0 Interface
Light value range -9999~9999
Peak intensity Repeatability ≤1.5%
Power source 220V / 50Hz, 110V / 60Hz
Standard energy consumption 200W
Dimensions (mm) 610mm×460mm×365mm
Weight 21kg