Fluid | gas without water molecules (except acetylene) |
Velocity range | 0~60m/s |
Accuracy | Reading±1%,full range±0.5% |
Repeatability | full range0.2% |
Temperature | Environmental conditions:-20ºC~70ºC;Medium temperature:-20ºC~120ºC or -20ºC~350ºC |
Power | 24VDC/220VAC |
Output | 4~20mA,pulse |
Response time | ≤1s |
temperature coefficient | 0.05%/ºC |
Communication interface | serial port output RS485,HART |
Screen content | quantity of heat,flow for short period;total flow |
Pressure | ≤4.2MPa |
connection | locking device/ball valve, flanged joint,Flange mounting |
Explosion proof grade | Exd II CT4 |
Ingress protection | Sensor IP67;transmitter IP65 |
Alarm point | Relay dry contact output, can choose the upper limit single alarm or lower limit double alarm |
Sensor diameter | 3mm/4mm/5mm |
Probe diameter | 18mm |
Sensor texture | 1Cr18Ni9Ti;304L;hastelloy C;Ta |
Probe texture | 1Cr18Ni9Ti;304L;hastelloy C;Ta |
Shell texture | Dangerous areas to install shell for powder coated aluminum castings |
Electrical interface | M20X1.5 |
Pressure loss | Pipe diameter greater than DN80 can be ignored |