GPU 50Hz 60Hz 400Hz 30kVA 45kVA 60kVA 90kVA 120kVA 200kVA 300kVA Airport 200V 115V 270V 28V Static Frequency Converter/Ground Power Unit/Aviation/Power Supply

Min.Order: 1
Product origin: Jinan, Shandong, China
Infringement complaint: complaintComplaint
US$ 55000 ~ 58000

Description
Product introduction

Features:
  1. The intermediate frequency power supply has the following technical characteristics:
  2. Adopting twelve pulse rectification technology, the input current distortion is low, the power factor is high, and the pollution to the power grid is small.
  3. Adopting pure digital control, high-frequency SPWM wave and full bridge inverter technology, the overall efficiency is high.
  4. Strong overload capacity, supporting up to 400% current overload.
  5. Excellent output stability and fast dynamic response.
  6. The protection function is complete, ensuring the normal operation of power equipment and the safety of loads.
  7. Can store up to 1000 error messages and quickly locate the cause of faults through fault codes.
  8. Black box function (the latest 50 error messages) to query the internal and external parameters of the power supply during a fault.
  9. Total output time and total loss power; Record the user's recent 200 operation records.
  10. LCD display. The interface is clear and intuitive, and the operation is simple and easy to use.
  11. The AC/DC output function can be completed through attachments.
Technical Parameters: 
ModelACME400-3390
InputPhase numberThree phase three wire+PE
Voltage380V/400V±15%
Frequency45~63Hz
Line current
Distortion
8.5%
PF>96%(100% load)
Impulse currentNone, with soft start function
OutputPhase numberThree phase four wire
Output voltage3 × 200/115V
Output power0~90KVA
PF0.7 lagging, 0.95 leading
Voltage regulation<0.5% (balanced load or 30% unbalanced load)
Total harmonic content<1.5% linear load
<2% non-linear load according to ISO1540
CF1.414±3%
Voltage modulation<1.0% (typical<0.5%)
Phase symmetry120 ° ± 1 ° (balanced load);
120 ° ± 2 ° (30% unbalanced load)
Frequency400Hz±0.1%
Output currentBelow 20% of rated current: 2% of range
Above 20% of rated current: 5% of range
Overload

 
>100% overload can work for 600 seconds
>125% overload can work for 60 seconds
>150% overload can work for 30 seconds
>200% overload can work for 10 seconds
>300% overload can work for 1 seconds
>400% overload immediate alarm
EfficiencyTotal efficiencycosΦ=0.8 full load,>0.93
Standby power<50W(fan stopped)
SetVoltage output100-130V
Voltage compensation0-9V
Delay waiting0-15mins
TimeYear, month, day, hour, minute, second
Interlocking power supplyOpen/Bypass
FanConstant speed/conventional
Fault recordReview/Clear
Power recordingReview/Clear
ProtectInput overvoltage and undervoltage protection, input phase sequence protection
Critical unit overheat protection
Internal power supply monitoring of each power supply
Output overvoltage and undervoltage (refer to MH/T6018 standard)
Output overload protection, output short circuit protection
EnvironmentWorking temperature-40ºC-+60ºC
Relative humidity10%-100%(non condensing)
Noise level<65dbB(A)(1m),usually 60dbB(A)
Protection standardsIP55(outdoor operation)
Service lifeService life>25 years
Mean time between failuresInverter section >25,000 hours
Ventilation section >100,000 hours
Mean time to repair (MTTR)
<20mins
 
RemarkThe testing conditions for setting errors/measuring trial errors are (25 ºC± 5 ºC);