Model | HL-80 (A~F) | HL -150 (A~F) | HL -225 (A~F) | HL -408 (A~F) | HL -800 (A~F) | HL -1000 (A~F) | |||||
Internal Dimensions WxHxD (mm) | 400x500 x400 | 500x60 0x500 | 600x750 x500 | 600x850 x800 | 1000x1000 x800 | 1000x1000 x1000 | |||||
External Dimensions WxHxD (mm) | 950x1650 x950 | 1050x1750 x1050 | 1200x1900 x1150 | 1200x1950 x1350 | 1600x2000 x1450 | 1600x2100 x1450 | |||||
Temperature Range | Low Temperature(A:25ºC B:0ºC C:-20ºC D:-40ºC E:-60ºC F:-70ºC) High Temperature 150ºC | ||||||||||
Analytic Accuracy/Distribution Uniformity of Temperature | 0.1ºC /±2.0ºC | ||||||||||
Control Accuracy of Temperature | ±0.5ºC | ||||||||||
Temperature Rising / Falling Velocity | Temperature rising approx. 0.1~3.0ºC/min ; temperature falling approx. 0.1~1.5ºC/min; ( The Falling Speed Rate Min.1.5ºC per minute is a special optional condition) | ||||||||||
Internal and External Material | Material of the inner box is SUS 304# stainless steel,of the outer box is stainless steel or see cold-rolled steel with paint coated. | ||||||||||
Insulation Material | Resistant to high temperature, high density, formate chlorine, ethyl acetum foam insulation materials | ||||||||||
Cooling System | Wind cooled or water cooled,single segment compressor for -40ºC, double segment compressor for -70ºC | ||||||||||
Protection Devices | Fuse-free switch, overloading protection switch for compressor, high and low voltage coolant protection switch, Over-humidity and over-temperature protection switch, fuses, fault warning system | ||||||||||
Optional Accessories | Inner door with operation hole(Optional), Recorder(optional),Dehumidifier | ||||||||||
Compressor | French Tecumseh Brand,Germany Bizer Brand | ||||||||||
Power | AC 220V, 1 phase 3 Lines,50/60HZ ; AC 380V ,3 phase 5 Lines,50/60HZ | ||||||||||
Approx. Weight (Kg) | 150 | 180 | 250 | 320 | 400 | 450 |