Explosion Proof Yc Mcp Myp Mining Power Cable

Min.Order: 500
Product origin: Zhengzhou, Henan, China
Infringement complaint: complaintComplaint
US$ 0.1 ~ 999

Description
WHY CHOOSE US






PRODUCT DESCRIPTION
 
Applications:
The product is suitable for connection in control, signal, protection circuit and measuring system with rated power-frequency voltage 450/750V or 0.6/1KV.
Push Pull Cable Auto Aisg Ret Flexible Motorcycle Control Cable Operating characteristics
1.The maximum permissible continuous operating temperature is 70ºC
2.The lowest installation temperature of the cable is 0ºC.
3.Permissible Min. Bending radius: not less than 6 times of the completed cable diameter for unarmoured cable; not less than 12 times of the completed cable diameter for armoured or copper tape screened cable; not less than 6 times of the completed cable diameter for screened flexible cable.


 
 
The technical data of  as below for reference,any customized is available.

 
 

SPECIFICATION

Normal type Flame retardant 
WDZC-YJY/WDZB-YJY/WDZ  YJY Cu conductor XLPE insulated PVC sheathed low smoke zero halogen flame resistant power cable 
WDZC-YJY23
WDZB-YJY23
WDZAYJY23  Cu conductor XLPE insulated polyolefin sheathed internal steel type armored low smoke zero halogen flame resistant power cable 
WDZC-KYJY
WDZB-KYJY
WDZA-KYJY  Cu conductor XLPE inSUlated polyolefin Sheathed low Smoke Zero halogen flame resistant control cable 
WDZC-KYJY23 WDZB-KYJY23 WDZA-KYJY23   Cu conductor XLPE insulated polyolefin sheathed internal steel type armored low smoke zero halogen flame resistant power cable 
.Standards:
The cable is manufactured according to GB/T 19666. The rated voltage Uo/U of the cable is up to 0.6/kV.
.Operation characteristic

1. Rated voltage Uo/U: up to 0.6/1kV
2. Maximum rated temperature
2.1 PVC insulated cable: The maximum operating tern­perature of cores shall not exceed 70°C when the cable is used for long period. The temperature of cores shall not exceed 160°C at short circuit (the max. duration dose not exceed 5 seconds).
2.2 XLPE insulated cable: The maximum operating temperature of cores shall not exceed 90°C when the cable is used for long period.The temperature of cores shall not exceed 250°C at short circuit (the max. duration dose not exceed 5 seconds).
.Installation requirement
Cable installation temperature shall not be less then 0°C.The permissible bending radius of cable shall not be less,then 10 times of the cable's diameter. The cable is suitable for the places have special requirement to fire resistance,light transmittance. HCI and toxicity..

Specification
Power cable
Nominal cross-sectional area:1.5-630mm2. 
Control cable
Nominal cross-sectional area:0.75-10mm2.
.Main Technical parameter
Flame resistant property
Test cable bunching combustion according to GB/T 19666 or IEC 60332-3 standards.
ZA: the nonmetal content of cable is 7L per meter, time of
supply fire is40 minute. 
ZB: the nonmetal content of cable is 3.5L per meter, time 
of supply fire is 40 minute. 
ZC: the nonmetal content of cable is 1.5L per meter, time 
of supply fire is 20 minute. 
Test result: the maximal charring height should not ex­ceed 2.5m.
 



Henan Kingyear Aluminum Industry Group was founded in 2006, located in Gongyi industry area of Henan Province. Our group consists of 3 main subsidiaries, business specialized in develop, manufacture and distribution of Aluminum products including Aluminum...

 
Product Tag:
Related categories:
Scroll to Top