Three-Phase 3kVA-300kVA Intermediate Frequency Power Supply Igbp/PWM 3∅ 4W+G Dpm-33060

Min.Order: 1
Product origin: Shanghai, China
Infringement complaint: complaintComplaint
US$ 200 ~ 60000

Description
PRODUCT INTRODUCTION:
        DP series frequency power supply of WENLIDA is high efficient and advanced AC simulated power supply. It can provide not only continuous, clear and stable sinuous voltage, but also automatic power transferring function in case of over temperature, over load and over voltage. Through IGBT/PWM mode, this power supply can output sinuous wave with high stability and low disturbance. Further more, it is designed with independent 3-phase circuit for the great imbalanced load capacity. Frequency output by the bit control, reasonable heat spreading system, wide range of output voltage, and high capacity utilization. The series products are good appearance and elegant, high precious digit indication, humanized operation panel and simplified program.

MAIN TECHNICAL SPECIFICATIONS:
PhaseTYPERated Capacity
(KVA)
Phase numberCircuit modeVoltage
(V)
Current
(A)
Size(mm)
Width*Height*Depth
Weight(kg)
HighLow



Single

 
DPM-500W0.51∅2W+GTransistor amplification mode

220V/
380V±10%
50Hz/
60Hz±3Hz



 
24430*540*20025
DPM-1100114830
DPM-110022IGBT/PWM


 
816430*540*70050
DPM-110033122475
DPM-110055204085
DPM-11010104284430*770*990145
DPM-110151563126165
DPM-110202083166195
DPM-31010103∅4W+G220/
380V±10%
50Hz/
60Hz±3Hz
4284155
DPM-310151563126185
DPM-310202083166275
DPM-3103030125250600*970*1240345
DPM-3104545187374450
DPM-3106060250500800*1090*1600580
DPM-3107575312624620
DPM-31100100417834820
DPM-3112512552110421200*1100*1600930
ThreeDPM-330033220/
380V±10%
48430*770*900120
DPM-330066816150
DPM-33010101326175
DPM-33015152040600*970*1240300
DPM-33020202754345
DPM-33030304182385
DPM-330454562124800*1090*1600528
DPM-330606083166635
DPM-3307075104208700
DPM-331001001382761000
DPM-331501502084161200*1100*16001400
DPM-332002002775541900
DPM-332502503746942000*1400*20002400
DPM-333003004168333000
Output phase voltageHIGH:10~300V  LOW:5~150V
AC output frequency50Hz ,60Hz,40~70Hz Continuously adjustable
(100Hz, 120Hz, 200Hz, 240Hz, 400Hz optional)
structural styleIt can provide four modes of cabinet type, vehicle mounted mode, suspension mode and rack mode
Load stability rate≤±1%(Pure resistive load)
Frequency stability rate≤±0.01%
Distortion rateTHD≤±2%(Pure resistive load)
Peak factor ratio3:1
Efficiency≥85%
Reaction time≤2ms
Display accuracyResolution 0.1V, voltmeter, ammeter, frequency meter 4.5 digit digital display (optional power meter)
Overload capacity120% delay 600s, 150% delay 60s, 200% delay 1s
Protection functionOver current protection, short circuit protection, over voltage protection, over temperature protection, self diagnosis protection and alarm device
ontrol function (optional)Remote control less than 30m, convenient for remote control of voltage, frequency, switching machine and other RS-485 / RS-232 / GPIB interface and control software
Protection levelIP30 or customized to meet the three defense requirements
Isolation Resistance500VDC/200MΩ
Stand voltage insulation1800VAC/5mA/1min
Cooling modeForced fan cooling
NoiseLess than 60dB at 1m

FUNCATIONAL FEATURES:         
1. Three phase independent design, able to withstand 100% unbalanced load for long-term operation;            
2. Strong overload capacity, 120% delay 600 seconds, 150% delay 60 seconds, 200% delay 1 second;            
3. Output voltage 21 / 36V, 115 / 200V, 220 / 380V can be selected, providing ± 15% adjustable range;            
4. Isolation transformer output, safe and reliable;            
5. Output frequency, 400Hz fixed output, 350hz-450hz continuously adjustable;            
6. IGBT / PWM mode, microprocessor control, frequency on-line adjustable, high precision, small size, light weight, low noise, high efficiency, operation and fault status at a glance, suitable for all kinds of loads.


USING CONDITIONS:          
1. Working temperature: -10 ºC ~ 70ºC            
2. Altitude: 1500m            
3. Relative humidity: 0-90% (non condensing state)            
4. The installation site shall be free of gas, steam, chemical deposition, dust, dirt and other explosive and corrosive media that seriously affect the insulation of the pressurizer;            
5. The installation site shall be free from serious vibration or turbulence            
6. Any special use conditions that do not meet the above provisions shall be determined by the user and our factory through negotiation

 


































 