Safety and Reliability Open Channel UV Water Treatment System

Min.Order: 1
Product origin: Wuxi, Jiangsu, China
Infringement complaint: complaintComplaint
US$ 1000 ~ 5000

Description
Safety And Reliability Open Channel UV Water Treatment System


Open channel UV disinfection systems, which are among the most cost-effective and high-tech treatment systems available today are designed to eliminate the use of chemicals in waste water that are discharged from treatment plants into nature, thereby minimizing the impact of waste water on the environment. Therefore the use of Open channel UV systems has increased rapidly in recent years.
This system which is designed using 24 high efficiency ultraviolet lamps eliminates microbiological contamination in the water with optimum efficiency. Thanks to a monitor that measures UV light permeability which has been incorporated into open channel ultraviolet system during the design phase, the residual build-up which occurs on the quartz sleeve over time is cleaned automatically. As a result, a high level of efficiency is attained due to the fact that UV rays can remain in the water at their maximum strength.

Open Channel UV disinfection System Key components:
1. UV module;
2. Manual/automatic cleaning system;
3. Power cabinet;
4. Electronic ballast;
5. US imported UV lamps from LIGHTSOURCE with a power of 320W and lifetime up to 12,000 hours;
6. Air cooling system;
7. Electric wiring and accessories;
8. Support rack;
9. System capacity is 5,000 T/D
10. Automatic water level control, UV intensity monitor, central PLC controller from Siemens with color touch screen.

Open Channel Ultraviolet Sterilizer System To customers Deatils:
01. What is the source of raw water to be treated?
--is it underground water or well water?or river water ,other source?
02. What is the capacity(m3/hour) you required for this sterilizer?
--most IMPORTANT requirement.
03. What will the treated water be used for?
--for human drinking or industry purpose?
04. What is the power supply in your country?

Typical Applications
Wide range of clean / waste water treatment
Lamp Type
Low-pressure, high-efficiency amalgam (monochromatic)
Ballast Type
Electronic, high-efficiency, variable output (60~100% power)
Input Power Per Lamp
320, 550 Watts/pc
Lamp Configuration
Horizontal, parallel to flow; Vertical to flow; 65°with the folow
Lamp Brand & Origin
Lightsource/Philip/Heraeus/Domestic brand
Module Configuration
8, 10 or 12 lamps per module
Level Control Device Options
Automatic Level Controller, Fixed weir or motorized weir gate
Water Level Sensor
1 electrode low water level sensor per channel
UV Intensity Sensor
1 UV detector for one sterilizer module
Working Temperature
4~60ºC/39.2~140ºF
Working Pressure
6 bar / 100psi
Enclosure Ratings
Module Frame/Ballast Enclosure
TYPE 6P (IP68) / TYPE 6P (IP67)
All Other Enclosures
TYPE 4X (IP56)
Ballast Cooling Method
Convection / Air conditioning / Forced air required
Installation Location
Indoor or outdoor
Module Frame/Chamber
SS304/SS316, Internal finish - Ra(max)0.8um
Sleeve Cleaning System
Auto-Cleaning System
Automatic Chemical/Mechanical (optional)
Auto-Cleaning WW Gel
Non-corrosive, operator-friendly, food-grade
Sleeve Spec
Quartz sleeves, UV transmittance >92%
Controller
PLC-based (Siemens/ Schneider PLC Standard Platform)
Electrical Requirements
Power Supply
220V, 50Hz (can be customized )
Electrical Cabinet
Working temperature 4~50ºC/39.2~122ºF, with power cord(2.5M)


Water quality factors that affect the disinfection efficiency and performance of the sewer UV water sterilizer system
1. Industrial waste water components of the incoming wale
2. The upstream treatment process and the chemical agents used
3. The UV light transmittance of the incoming flow
4. Content of the suspended matters
5. Particle size distribution

Design of the concise and l