Model | JAGUAR M8 | |
Heating System | Number of heating zones | UP 8/BOTTOM8 |
Length of heating zones | 2900MM | |
Heating mode | hot air | |
Cooling Mode | Force air | |
Conveyor System | Max. Width of PCB | 350mm |
Mesh belt width | 400mm | |
Transmission Direction | L→R(or R→L) | |
Transmission Net Height | 880±20mm | |
Transmission type | Mesh and chain | |
Range of rail width | 0-300mm | |
Conveyor speed | 0-1500mm/min | |
Auto/manual Lubrication | standard | |
Upper hood method | Manual(option:auto) | |
Fixed rail side | Front rail fixed(option: rear rail fixed) | |
Components high | Top and bottom 25mm | |
Control system | Power supply | 5line 3phase 380V 50/60Hz |
Total power | 40kw | |
Starting power | 38kw | |
Normal power consumption | 4KW | |
Warming time | About 20 mins | |
Temp. setting range | Room temperature-300ºC | |
Temp. control method | PLC & PC | |
Temp. control precision | ±1ºC | |
Temp. deviation on PCB | ±2ºC | |
Data storage | Process Data and status storage(80GB) | |
Nozzle plate | Aluminum Alloy Plate | |
Abnormal Alarm | Abnormal temp. (extra-high/extra-low temp.) | |
Board dropped alarm | Tower light: Yellow-warming, Green-normal, Red-abnormal | |
General | Dimension(L*W*H) | 4400×1100×1490mm |
Weight | 1000KG | |
Color | Computer gray |