Open Channel UV Water Sterilizer System With Automatic Control

Open channel UV water treatment systems are mainly used at the municipal water/wastewater treatment plants for water recycling and effluent disinfection to ensure a better level of environmental protection.

UV disinfection is an effective and environmentally friendly alternative to the conventional chlorine effluent disinfection. Nowadays more than 15% of 2000 waste water treatment plants in North America have chosen the UV as the primary disinfection method. UV disinfection has proved its safety, reliability, efficiency, and economical characteristics over the years.

 Open channel UV sterilziers GT series have been used for waste water, sewage water desinfection in order to achieve a lower envirionment pollution drainage.




Water quality factors that affect the disinfection efficiency and performance of the sewer UV treatment system
1. Industrial waste water components of the incoming wale
2. The upstream treatment process and the chemical agents used
3. The UV light transmittance of the incoming flow
4. Content of the suspended matters
5. Particle size distribution

Disinfection system factors that affect the disinfection efficiency and performance of the sewer UV treatment system

1. Hydrodynamic design of the sterilizer (Maximize the use of UV performance to increase the disinfector efficiency and reduce the water pressure loss

2. Lamp tube performance (including the system aging)

3. Arrangement of lamp tubes

4. Scale coefficient of lamp tubes

5. Performance of ballast

 

Design of the concise and lightweight bent frame

1. IP68 or equal grade of sealing protection. High-efficient secure multi-level sealing waterproof design.

2. The module adopts the push-in connectors with the less water resistance so as to guarantee the water incoming before disinfection and water discharge after disinfection.

3. There is little change in water level as to guarantee a stable sterilization effect.

4. It does not need any special tools to disassemble and assemble the disinfection module.
 

To customers details

Deatils:

01. What is the source of raw water to be treated?

 --is it underground water or well water?or river water ,other source?

02. What is the capacity(m3/hour) you required for this sterilizer?

 --most IMPORTANT requirement.

03. What will the treated water be used for?

--for human drinking or industry purpose?

04. What is the power supply in your country?
Open Channel sterilizer system specification
 

Capacity320W lamp qtyModelNote
M3/dayStand ALamp powerStand BLamp powerStand AStand BCoefficient of variation
5000247.68165.12YLD-320W-3-8YLD-320W-4-4K= 1.3
100003611.52247.68YLD-320W-4-9YLD-320W-3-8K=1.3
150005617.923210.24YLD-320W-7-8YLD-320W-4-8K=1.3
200006420.484815.36YLD-320W-8-8YLD-320W-6-8K=1.3
250008025.65617.92YLD-320W-10-8YLD-320W-7-8K=1.3
300009630.726420.48YLD-320W-12-8YLD-320W-8-8K=1.3
35000100328025.6YLD-320W-10-10YLD-320W-10-8K=1.3
4000012038.48828.16YLD-320W-12-8YLD-320W-11-8K=1.3
5000016051.29630.72YLD-320W-20-8YLD-320W-12-8K=1.3
6000020866.5612840.96YLD-320W-26-8YLD-320W-16-8K=1.3
8000023073.615248.64YLD-320W-23-10YLD-320W-19-8K=1.3
10000025681.9216051.2YLD-320W-32-8YLD-320W-20-8K=1.3
1500003009624076.8YLD-320W-3-8YLD-320W-24-8K=1.3
180000320102.430096YLD-320W-3-8YLD-320W-25-8K=1.3
200000360115.2320102.4YLD-320W-30-12YLD-320W-40-8K=1.3
Application:
Typical ApplicationsWide range of clean / waste water treatment
Lamp TypeLow-pressure, high-efficiency amalgam (monochromatic)
Ballast TypeElectronic, high-efficiency, variable output (60~100% power)
Input Power Per Lamp320, 550 Watts/pc
Lamp ConfigurationHorizontal, parallel to flow; Vertical to flow; 65°with the folow
Lamp Brand & OriginLightsource/Philip/Heraeus/Domestic brand
Module Configuration8, 10 or 12 lamps per module
Level Control Device OptionsAutomatic Level Controller, Fixed weir or motorized weir gate
Water Level Sensor1 electrode low water level sensor per channel
UV Intensity Sensor1 UV detector for one sterilizer module
Working Temperature4~60ºC/39.2~140ºF
Working Pressure6 bar / 100psi
Enclosure Ratings
Module Frame/Ballast EnclosureTYPE 6P (IP68) / TYPE 6P (IP67)
All Other EnclosuresTYPE 4X (IP56)
Ballast Cooling MethodConvection / Air conditioning / Forced air required
Installation LocationIndoor or outdoor
Module Frame/ChamberSS304/SS316, Internal finish - Ra(max)0.8um
Sleeve Cleaning System
Auto-Cleaning SystemAutomatic Chemical/Mechanical (optional)
Auto-Cleaning WW GelNon-corrosive, operator-friendly, food-grade
Sleeve SpecQuartz sleeves, UV transmittance >92%
ControllerPLC-based (Siemens/ Schneider PLC Standard Platform)
Electrical Requirements
Power Supply220V, 50Hz (can be customized )
Electrical CabinetWorking temperature 4~50ºC/39.2~122ºF, with power cord(2.5M)
Projects:



Our Services

We provide 24 hours online customer service.

Any inquiry about water treatment system, please feel free to contact me for further details!

Contact information:
Mobile phone: +86 13585066069
 

 
Alibaba website: http://yldwater.en.made-in-china.com
Official website: yldwater.en.made-in-china.com
Guarantee period:1 year
After-sale service:800-827-87-226