20/25 Mva 46 / 6.3 Kv 60Hz 3phases 2windings Power Transformer with Dga on Line Monitor System and Protection of Bushing Oltc Winding Oil Temperature IEC61850

Min.Order: 1
Product origin: Ningbo, Zhejiang, China
Infringement complaint: complaintComplaint
US$ 300000

Description
SPECIFICATION  
   
2.4.1  TECHNICAL SPECIFICATION FOR STEP UP  
POWER TRANSFORMER35/40MVA  STEP UP TRANSFORMER35/40MVA  STEP UP TRANSFORMER
Sl. No.   Particulars   Factory DataFactory Data
1.0   GENERAL     
1.1   Name of Manufacturer    HEMG
1.2   Description     
 The specification refers to a Three Phase Oil  
immerged ONAN/ONAF Cooling according to VDE/IEC/DIN/BS Standard.  
2   Rated KVA   35000/4000035000/40000
3   No Load Voltage Ratio   6.6/132KV6.6/132KV
4   No. of Phase    HT -3 , LT - 3HT -3 , LT - 3
5   Cooling    ONAN/ONAF ONAN/ONAF
6   Installation    OutdoorOutdoor
7   Frequency    50 Hz50 Hz
8   Winding connection and material    Star-Delta, Copper Star-Delta, Copper
9   Vector Group    Ynd1Ynd1
10   tap  
  - Range    +10% to -20% at HV side.+15% to -15% at HV side.
  - No. of steps/POS    24 Steps, 25 Position 24 Steps, 25 Position
  - Variation per step, %   1.25%1.25%
11   Temperature rise, Deg. C     
  - Top oil    50 0C 50 ºC
  - Winding    55 0C55 ºC
12   Total loss at rated voltage at principal tapping and rated  
frequency, kW   192.22190.22
13   Component losses, kW     
  - No load loss at rated voltage at principal  
 tapping and rated frequency, kW   3028
  - Load loss at rated current at principal tapping at 75 Deg. C160(122 ONAN)160(122 ONAN)
  - Auxiliary Loss   2.222.22
14   Impedance at rated current for principal tapping, %    11.35%11.5%
15   No load current at rated voltage and frequency, Amps     
16   Full wave lightning impulse withstand kVp    650 HV/ 70  LV650 HV/ 95 LV
17   Efficiency at 75 Deg. C at unity power factor, %     
  - At full load   99.682499.52%
  - At 75% load    99.683399.50%
  - At 50% laod   99.685299.45%
18   Regulation at full load     
  - At unit pf  44
  - At 0.8 lagging pf   10.0110.01
19   Details of tap changer     
  - Make   Huaming ChinaHuaming China
  - Type     
  - Range    +10% to -20% at HV Side.+15% to -15% at HV side.
20   No. of steps/Position    24/2524/25
  a) Rated Voltage, kV    132 kV72.5 kV
  b) Step Voltage, V    1.25%1000-1500V
21   Terminal arrangement     
  - HV     Bushing 
  - LV     Bushing 
  - Neutral     Bushing 
22   Approximate masses, Kg     
  - Core & Windings    2930031600
  - Tank, fittings & accessories    1920012000
  - Oil    1450012000
  - Total   6300055600
23   Heaviest package, Kg   49050(WITH OIL)50000(WITH OIL)
24   Overall dimensions    6260*4950*5380mm(L*W*H)
   
25  Auxiliary power voltage  
AC3-phase, 220-240/415-440V, 50Hz3-phase, 220-240/415-440V, 50Hz
 1-phase, 220-240Vac, 50Hz1-phase, 220-240Vac, 50Hz
DC110Vdc110Vdc
   
FITTINGS & ACCESSORIES:  
   
The following fittings and accessories will be YESYES
provided along with the main transformers.  
 YESYES
1Rating and diagram plate  
 YESYES
a) Two (2) Nos. safety earthing terminals for   
transformer tank and radiator banksYESYES
b)Lifting lugs  
 YESYES
c)Jacking pads  
 YESYES
d)Skids  
   
e)Pulling eyes  
 YESYES
f) Terminal marking plate  
   
g) Conservator (main chamber and OLTC chamber) with filling cap. drainYESYES
valve, vent pipe and equaliser connection.  
 YESYES
h)RTCC Panel  
   
i)Magnetic type oil level indicator with 150mm dia dial and alarmYESYES
initiating contacts for low and high oil levels.  
 YESYES
j) Explosion vent with double diaphragm  
 YESYES
k)Inspection cover  
 YESYES
l)Pressure relief device  
 YESYES
-   Air release devices  
   
-   De-hydrating breather complete with 1st fill of activated alumina orYESYES
silica gel  
   
-   150 mm dial type oil temperature indicator with alarm and tripYESYES
contacts and maximum reading pointer.  
   
-   150 mm dial type winding temperature indicator with alarm & tripYESYES
contacts and maximum reading pointer.  
   
-   Double float Buchholz relay with alarm and trip contacts, tests,YESYES
cocks and window to view the trapped gas.  
   
-   Oil drain valve at bottom.YESYES
   
-   Oil sampling valves at top, middle and bottom.YESYES
   
-   One (1) shut-off valve each, on either side of Buchholz relay.YESYES
   
-   Sampling gas collectors for Buchholz relay at accessible height.YESYES
   
-   Bank of radiators with isolating valves at top and bottom for  
connections between the transformer tank and radiator banks.YESYES
   
-   Plain oil level gauge.SIZE DESIGN AS PER USSIZE DESIGN AS PER US
   
-   Bi-directional flanged rollers suitable for 1676 mm gauge.2000x14352000x1435
   
-   Weather proof marshalling box for housing dial type temperature  
indicators, terminal blocks etc. and complete with toughened glass  
window, space heater, internal illumination etc. The wiring from  
various accessories / fittings to marshalling box will be by 1.1 kV  
grade PVC insulated, sheathed and armoured copper conductor cable of  
size 2.5 sq.mm. Marshalling box shall be mounted on the transformerYESYES
tank and not on radiator banks.  
   
-   Climbing rungs or ladder.YESYES
   
X   HV neutral bushing  
 TERMINAL BOX SHOW WTI OTITERMINAL BOX SHOW WTI OTI
-   WTI CT terminal box  
   
-   Earthing terminal with M12 tapped holes  
   
x   HV and LV cable boxes with bushingsLT bushing up outline with flange,HT CANCELLT bushing up outline with flange,HT CANCEL
   
-   On Load Tap Changer (OLTC) with oil surge relay, RTCC, AVR  
   
-   Oil filler pipe with cap for transformer conservator and OLTC  
Chamber (50 mm dia).  
CT  
HV CT: 200/1 , 15 VA, 5P 20HV CT: 300/1 , 15 VA, 5P 20  1PC/PHASEHV CT: 100/1 , 15 VA, 5P 20  1PC/PHASE
   
HV Neutral CT: 200/1-1. (Two core) 15 VA 5P 20 for REF & SEFHV N CT: 300/1  15 VA 5P 20   1PC/PHASEHV N CT: 100/1  15 VA 5P 20   1PC/PHASE
   
LV CT : 2400/1,  15 VA, 5P20LV CT : 4000/1,  15 VA, 5P20  1PC/PHASELV CT : 1200/1,  15 VA, 5P20   1PC/PHASE
   
WTI CT: 1837/5 A (Depends on your WTI)WTI  CT: 300/5 AWTI  CT: 100/5 A
 