Med-Pm-9000c ECG 12 Inch Portable Patient Monitor Medical Equipment

Min.Order: 1
Product origin: Guangzhou, Guangdong, China
Infringement complaint: complaintComplaint
US$ 480

Description
Good quality  Patient Monitor in hot sales
MED-PM-9000C 


8" color TFT LCD screen,resolution 800*600
Lightweight: 1.35KG(with battery)
Waterproof design, Resistance to dropping (1 meter)
Low power consumption, fanless structure which creates no noise.
Support external 13-20V DC power, continously working for 5.5 hours above on battery backup,full charge with 2.5 hours, suitable for Ambulance,Emergency Transport
Display mode: Big font, trends review, 7 leads ECG waveform on same screen, and etc.
15 kinds of arrhythmia analysis, 15 kinds of drug concentration analysis
Anti-electrosurgical unit(300W),anti defibrillator (360J), suitable for Operating Room, General Ward. Digital SpO2 technology,excellent anti-interference performance, low perfusion (0.1%)


Technical Specifications

ECG
Lead Mode                                     5 Leads (R, L, F, N, C or RA, LA, LL, RL,V)
Lead selection                               I, II, III, avR, avL, avF, V
Wave form                                      2 ch
Lead mode                                      3 Leads ( R, L, F or RA, LA, LL)
Lead selection                               I, II, III,
Wave form                                      1 ch
Gain                                                  2.5mm/mV, 5.0mm/mV, 10mm/mV,
20mm/mV, auto
HR and Alarm Range                    Adult   15 ~ 300 bpm
Neo/Ped   15 ~ 350 bpm
Accuracy                                          ±1% or±1bpm, which is greater
Resolution                                      1 bpm
Sensitivity                                       > 200 (uVp-p)
Differential Input Impedance      > 5 MΩ
CMRR                                                Monitor > 105 dB
Operation > 105 dB
Diagnosis > 85 dB
Electrode offset potential         ±300mV
Leakage Current                           < 10 uA
Baseline Recovery                        < 3 S After Defi.
ECG Signal Range                          ±8 m V ( Vp-p )
Bandwidth                                      Surgery   1 ~ 20 Hz
Monitor   0.5 ~ 40 Hz
Diagnostic  0.05 ~ 130 Hz
Calibration Signal                         1 (mVp-p), Accuracy:5%
ST Segment Monitoring Range     Measure and Alarm -2.0 ~ +2.0 mV
ARR Detecting                               Type: ASYSTOLE, VFIB/VTAC, COUPLET,
BIGEMINY, TRIGEMINY, R ON T, VT>2,
BRADY, MISSED BEATS, PNP, PNC,
Alarm Available,Review Available

Alarm Type                                      SYS, DIA, MEAN Measuring and alarm range      Adult Mode
SYS 40 ~ 270 mmHg DIA 10 ~ 215 mmHg MEAN 20 ~ 235 mmHg Pediatric Mode
SYS 40 ~ 200 mmHg DIA 10 ~ 150 mmHg MEAN 20 ~ 165 mmHg Neonatal Mode
SYS 40 ~ 135 mmHg DIA 10 ~ 100 mmHg MEAN 20 ~ 110 mmHg
Resolution                                      1mmHg
Accuracy                                         Maximum Mean error ±5mmHg
Maximum Standard deviation ±8mmHg
Overpressure Protection           Adult Mode 297±3 mmHg
Pediatric Mode 240±3 mmHg
Neonatal Mode 147±3 mmHg
 
SpO2
Measuring Range                          0 ~ 100 %
Alarm Range                                   0 ~ 100 %
Resolution                                      1 %
Accuracy                                          70% ~ 100% 2 %
0%  ~  69% unspecified
Actualization intervalabout      1 Sec.
Alarm Delay                                    10 Sec.
Pulse Rate                                       Measuring and Alarm Range 20~300 bpm
Resolution      1bpm
Accuracy ±3bpm

 
Respiration
Method                                            Impedance between R-F(RA-LL)
Differential Input Impedance      > 2.5 MΩ
Measuring Impedance Range     0.3~3 Ω
Base line Impedance Range      200~4 KΩ
Bandwidth                                      0.1~2.5Hz
Resp. Rate                                       Measuring and Alarm Range
Adult 0 ~ 120 Brpm
Neo/Ped 0 ~ 150 Brpm
Resolution 1 Brpm
Accuracy ±2 Brpm
Apnea Alarm                                  10 ~ 40 S

 
TEMP
Channel                                            2
Measuring and Alarm Range     0 ~ 50ºC
Resolution                                       0.1ºC
Accuracy                                          ±0.2ºC
Actualization intervalabout      1 Sec.
Average Time Constant               < 10 Sec.


NIBP
Method        Oscillometric
Mode       Manual, Auto, STAT
Measuring Interval in AUTO Mode  1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180,
240,480 (Min)
Measuring Period in STAT Mode   5 Min
Pulse Rate Range 40 ~ 240 bpm

       
 
Standard: ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature