Vacuum Circuit Breaker Vcb Testing Kit/Vacuum Bottle Integrity Testing Machine

Min.Order: 1
Product origin: Baoding, Hebei, China
Infringement complaint: complaintComplaint
US$ 2500 ~ 2871

Description
Vacuum Circuit Breaker Vcb Testing Kit/Vacuum Bottle Integrity Testing Machine

I.Introduction
In JB8738-1998 vacuum interrupter arc chamber of 3.6-40.5KV AC high voltage switchgear established by high-voltage switchgear National Standardization Technical Committee, it is prescribed that the internal gas pressure measurement and allowable storage time limit inspection must be executed for any user and producer of interruption arc chamber of high-voltage vacuum switchgear. At the same time, in National Standardization -JB8738-1998, it is also noticed that allowable storage time limit of interruption arc chamber should be 20 years, and internal gas pressure of the vacuum interrupter arc chamber should be less than 6.6×10-2Pa.

HZ-ZKD vacuum tester for vacuum switchgear is the latest generation of products of my company, it is the upgrade product in the base of HZ-ZKD vacuum meter on the foundation of notion from the field user. HZ-ZKD vacuum tester has some features-  higher measurement accuracy, better stability, more capacity.

For vacuum circuit breaker, the method of determining whether or not deterioration of the vacuum tube is inspection with the method of frequency withstand voltage, but this method only distinguish the vacuum interrupter arc chamber of the serious deterioration. When the vacuum of vacuum interrupter arc chamber degrade to 10-2-10-1 Pa, although the breakdown voltage is not reduced, but the interrupter arc chamber has failed. In the HZ-ZKD vacuum tester for vacuum switch, the new field coils were used, and with the magnetron discharge method the vacuum of the vacuum interrupter arc can be measured without disassembling the interrupter arc chamber. At the same time, HZ-ZKD vacuum tester also used computer for synchronous control, data acquisition and processing, and the sensitivity of HZ-ZKD vacuum tester in the field test of the vacuum interrupter arc chamber is 10-5Pa. The most prominent feature of this instrument (HZ-ZKD vacuum tester) is to use the new excitation coils and data processing methods to achieve the non-demolition measurement of vacuum. The instrument is practical, easy to use, easy to operate, high precision measurement without disassembly, widely used in electric power, steel, petrochemical, textile, coal, railways, and other trades using the vacuum switch.


II.Specifications

 Detection objects: various models of vacuum switch

 Detection method: using new excitation coil and detect vacuum tube without                  

disassembly

 Application area: This instrument is a all-purpose type, can measure the vacuum  

           of variety models of open magnetic vacuum tube.

 Detection range: 10-5-10-1 Pa

 Measurement accuracy: 10-5-10-4 Pa, 15%

10-4-10-3 Pa, 15%

10-3-10-2 Pa, 10%

10-2-10-1 Pa, 10%

 Magnetic field voltage: 1700V

 High-voltage of pulsed electric field: 30KV

 Open distance of switch tube in vacuum test: normal open distance

 Testing environment: -20ºC~ 40ºC

 Weight: 24kg

 Dimension: 420 × 320 × 280 (mm)

 Sampler: magnetic coil

 
Company Information
HuaZheng Electric Manufacturing (Baoding) Co.,Ltd is the supplier of the State Grid in China.It means we are the supplier of the Chinese Government.And our products spread throughout the whole China.

What's more, our customers come from different countries like America, England, Bulgaria, Brazil, Chile, Malysia, Vietnam and so on.


Our main products are Insulation Oil Tester, Cable Fault Locator, Power Quality Analyzer, High Voltage Generator, High Voltage Capacitor, Testing Transformer and so on.




Customer Visit



Exhibition
Similar Recommendation


Scroll to Top