Lk-U31 Portable Dental Patient Moniter for Surgery with ECG, RespiratoryRate

Min.Order: 1
Product origin: Zhengzhou, Henan, China
Infringement complaint: complaintComplaint
US$ 350

Description
Lk-U31 Portable Dental Patient Moniter for Surgery with ECG, RespiratoryRate

Portable Patient Monitor performs monitoring of:
ECG Heart Rate (HR)
 2-channel ECG waveforms
 S-T segment analysis
 Arrhythmia (optional)
RESP Respiratory Rate (RR)
 Respiration Waveform
SpO2Oxygen Saturation (SpO2), Pulse Rate (PR)
 SpO2 Plethysmogram
NIBP Systolic Pressure (NS), Diastolic Pressure (ND), Mean Pressure (NM)
TEMPTemperature DATA
IBPIBP DATA
Portable Patient Monitor (Figure 1-1) is adaptable to adult, pediatric and neonatal usage. It can monitor
vital signals as ECG, Respiratory Rate, SpO2, NIBP, TEMP and IBP. It integrates parameter measuring
modules, display and recorder in one device, featuring in compactness, lightweight and portability.
Replaceable built-in battery facilitates transportation of patient. Large high-resolution display provides
clear view of 5 waveforms and full monitoring parameters.
The POWER switch is on the left quarter of the front panel (in Figure 1-1). The POWER indicator(in
Figure 1-1) and the BATT indicator ( in Figure 1-1) lights when the device is powered on. The
ALARM indicator flashes or lights when alarm occurs ( in Figure 1-1).The sockets of the sensors are
at the right side. The recorder socket is at the left side. Other sockets and power plug-in are at the
back.

Do not immerse the connector in any liquid. After cleaning, dry the transducer thoroughly before
storing. Slight discoloration or temporary increase of surface stickiness of the cable should not be
considered abnormal If adhesive tape residue must be removed from the transducer cable, double
seal tape remover is effective and will cause a minimum of damage to the cable if used sparingly.
Acetone, Alcohol, Ammonia and Chloroform, or other strong solvents are not recommended
because over time the vinyl cabling will be damaged by these agents.

Liquid Chemical Sterilization
Remove obvious contamination by using the cleaning procedure described previously. Select a
sterilant that your hospital or institution has found to be effective for liquid chemical sterilization
of operating room equipment. Buffered gluteraldehyed (e.g. Cidex or Hospisept) has been
found to be effective. Do not use quaternary cationic detergents such as zephiran chloride. If
the whole unit is to be sterilized, immerse the transducer but not the electrical connector into
the sterilant for the recommended sterilizing period. Be sure that the dome is removed. Then
rinse all transducer parts except the electrical connector with sterilized water or saline. The
transducer must be thoroughly dried before storing.

Gas Sterilization
For more complete asepsis, use gas sterilization.
Remove obvious contamination by using the cleaning procedure described previously. To
inhibit the formation of ethylene glycol when ethylene oxide gas is used as the disinfectant, the
transducer should be completely dry.
Follow the operating instructions provided by the manufacturer of the gas disinfectant.