Oxima vital signs monitor adopts Oscillometry for NIBP measuring Photoelectric Oxyhemoglobin Inspection Technology combining Capacity Pulse Scanning & Recording Technology for SpO2 measuring. Systolic Pressure (SYS) Diastolic Pressure (DIA) Mean Pressure (MAP) SpO2 and Pulse rate (PR) can be accurately measured. Oxima2 Compact appearance comprehensive functions simple and convenient operation which is applicable for hospitals community medical treatment and family. Uses for medicine surgery operating room ICU/CCU emergency room obstetrics and gynecology pediatrics
FEATURES:
Easy to use and high cost performance. Built-in rechargeable Li-polymer battery for uninterrupted monitoring. Compact and flexible appearance easy for carrying and be suitable for indoor and outdoor(in ambulance) monitoring. With user-friendly interface. Display with 2.4'' (320×240) color TFT LCD and blue highlight LED. Visual and audible alarm for Systolic Pressure(SYS) Diastolic Pressure(DIA) Mean Pressure(MAP) SpO2 and Pulse rate(PR) and upper and lower limit of alarm can be set. Unique Flash memory storage for up to 2000 NIBP data or SpO2 data within 48-hour. Convenient and quick in inquiring measurement data. For adult, Child and New born Optioans: Temperature. Thermal Printer
SPECIFICATIONS:
Type of Patient monitor Class I & Type BF defibrillation-proof applied part Recall NIBP Measurement Recall 2000 NIBP measurements SpO2 Measurement Recall 65000 SpO2 measurements Display Display mode SpO2 2 figures LED, LCD PR 3 figures LED NIBP 3 figures LED SpO2, BPM graphics trends, SpO2 plethysmogram waveform Waveform LCD SpO2 Measuring Range 35%~100% Alarm Range 0%~100% Resolution 1% PR Measuring Range 30~250BPM Alarm Range 0~254BPM Resolution 1BPM NIBP Method Oscillometry Mode Manual, Auto Measuring Interval in AUTO Mode 1-255 Min Alarm Type Sound, LCD display Adult: Systolic pressure: 40mmHg~270mmHg Mean pressure: 20mmHg~235mmHg Diastolic Pressure: 10mmHg~215mmHg Pediatric: Systolic pressure: 40mmHg~200mmHg Mean pressure: 20mmHg~165mmHg Diastolic Pressure: 10mmHg~150mmHg Neonatal: Systolic pressure: 40mmHg~135mmHg Mean pressure: 20mmHg~110mmHg Diastolic Pressure: 10mmHg~100mmHg Upper and lower limit of alarm
Resolution:
Accuracy for pressure 1mmHg Accuracy for cuff pressure ±3mmHg Accuracy for Measurement Maximum Mean error ±5mmHg Maximum Standard deviation 8mmHg Overpressure Protection Adult Mode 297±3mmHg Neonatal Mode 147±3mmHg Battery 7.4V 2000mAh Lithium ion polymer battery; It can work for about 5 hours continuously when charged fully enough. Dimension and weight Dimension 232mm(L)×198mm(W)×75mm(H) Net weight 1.15 Kg