Input Type Cable Hydrostatic Liquid Level Transmitter

Min.Order: 1
Product origin: Xingtai, Hebei, China
Infringement complaint: complaintComplaint
US$ 60

Description
Product Description

    Hydrostatic pressure Level Transmitter are used to measure the liquid level in open tank which surface pressure equal to ambient pressure. It is a Submersible Water Level Sensor, drop-in the cable to liquid directly to test the liquid level. The Level transmitter sensing element are all adopts high performance pressure core. Our static pressure level indicator's industrial structures are all stainless steel sealed. The amplifying circuit has been laser compensated which can assure the measured data reliable. Electrical connection cable applies military

anti-corrosion air-conduction cable, so back-pressure chamber directly connected with the atmosphere. The Hydrostatic pressure level gauge are especially suitable for various industrial tank liquid measurements. These type products can transmit the measured pressure to 4 ~ 20mA standard current signal, and be combined with other instruments to achieve automatic control. 
    These type products are widely used in petroleum, chemical, textile, metallurgy, electric power, water conservancy, environmental protection, beer and ships tanks, etc.
Measure range
0~1~300m H2O
Working temperature
-20 ºC ~ 80ºC
Temperature compensation
-10~70ºC
Storage temperature
-40~80ºC
Over load pressure
2times of measure range
The accuracy class
Class 0.1% FS, the basic error is ±0.1%; 
Class 0.2% FS, the basic error is ±0.2%; 
Class 0.5% FS, the basic error is ±0.5%.
Hot zero drift
When the condition temperature is out of the working temperature range, the transmitter's zero drift value can be not bigger than 0.03%FS/ ºC.
Hot sensitivity drift
With high accuracy, good stability; The sensor can realize temperature compensation in temperature 0~65ºC, and through circuit compensation, it can eliminate the effects which because of temperature drift.
Insulation resistance
During the defined temperature range, the insulation resistance value between the transmitter ends and ground can't be less than 20MΩ/250V.
 Explosion-proof performance
Exia II CT4
Output
4-20mA (2-wire), (0~10/20)mA; (0~5)V, (1~5)V,(0~10)V(3-wire), With Modbus communication (Modbus Serial RS485); 4~20mA+Hart
Power supply
12~36 VDC (nominal voltage 24VDC)
Material
Shell material: Alloy Aluminum; O ring: VITON; Membrane:316L stainless steel
Protection class
IP68(pressure sensor), IP65(Junction box transmitter)
Company Profile