Description
GF102 Portable Single Phase Electric Meter Testing System,CE,ISO9001:2008,IEC approved,english version display, two years quality warranty.
Product Description
GF102 portable single phase energy meter testing set used to test single phase energy meter. Adopt mature signal synthetic and power amplifier technology. High precision voltage and current output. Widely used in lab and field. And then as single phase standard source or single phase phantom load source.
Features
Meter under testing: 1P2W
Testing mode: Active power, reactive power.
Test 3PCS or 2PCS meter synchronously.
Starting test and creeping test.
Reference standard and power source integrated, easy to carry.
Measuring mechanical meter and electric meter.
Operating by manual keyboard or PC software
With shortcut key of normal test point, speed up testing
Internal large capacity storage device for mass memory
Local checking the testing result
Overload, short circuit, open circuit protection
With self-checking function
Product Parameters
Voltage |
Test voltage output (Phase-Neutral) | 0V - 264V |
Power of the voltage output | Max. 30VA, 15VA |
Resolution | 0.01% |
Accuracy | 0.1%, 0.2% |
Stability | 0.02%/120s, 0.05%/120s |
Distortion factor | < 0.3% for linear resistance load |
Current |
Test current output | 1mA - 120A, 1mA - 60A |
Power of the current output | Max. 100VA, 30VA |
Resolution | 0.01% |
Accuracy | 0.1%, 0.2% |
Stability | 0.02%/120s |
Distortion factor | < 0.3% for linear resistance load |
Phase angle |
Range | 0 -- 360° |
Resolution | 0.1° |
Accuracy | 0.2° |
Frequency |
Range | 45Hz - 65Hz |
Resolution | 0.005Hz |
Pulse output |
High frequency output(CH) | 1.666× 10 5 Hz |
Low frequency output(CL) | 5× 10 -5 × CH |
Pulse input |
Input channel | 3 |
Input frequency | Max. 20Hz |
Other |
Voltage Supply | 220V± 10% 50/60Hz± 2Hz |
Ambient temperature | -10° C-- +40° C |
Relative humidity | 35% -- 85% |
Dimensions (W × D × H) (mm) | 445× 440× 180, 410× 220× 150 |
Weight (kg) | 18, 9.5 |
Detailed Photos