Brotie High Purity Oxygen Analyzer (Economical and Professional models)

Min.Order: 1
Product origin: Beijing, China
Infringement complaint: complaintComplaint
US$ 500 ~ 2150

Description




BROTIE High Purity Oxygen Analyzer(Economical model)

Features:
  • New pattern, long-life, with long service life, fast response and high sensitivity;
  • Sensor designed by ion current technology;
  • Menu locking function provided, avoid the misoperation to change the parameters on the analyzer;
  • Automatically memorizing system equipped, operation time of the analyzer will be recorded automatically ;
  • Compact size, simple construction, easy on operation and after service;
Industries Served:
It can be used in high purity oxygen production(PSA, VPSA, Cryogenic), metallurgy, health, petrochemicals, and power electronics industries.
Specifications:
Range:10.00%-96.00%, 10-99.00%(special model)
Accuracy:±2% of FS range, ±0.2% of 80-99%
Repeatability:±1% of FS range
Principle:Ion current technology (can service in Air and inert gases, not corrosive gases.)
Sample gas flow speed:400~600ml/min
Stability:±1% of FS/7d
Response time:90% of FS reading in 60 seconds
Power supply:220V±10%, 50/60Hz
Signal outputs:4-20mA
Expected analyzer life:More than 5 years (in normal condition)
Expected sensor life:2-3 years (in normal condition)
Installing dimension:W×H×D=150mm*74mm*167mm


BROTIE High Purity Oxygen Analyzer(Professional model)

Features:
  • New pattern, long-life, conversion ion current tester with fast response and high sensitivity;
  • A standard RS232C interface;
  • Setting alarm value and contact output value arbitrarily;
  • High precision, automatic temperature compensation, eliminating the impact of environmental temperature;
  • Setting upper and lower alarm values arbitrarily during the measurement range;
Industries Served:
It can be used in high purity oxygen production, metallurgy, health, petrochemicals, and power electronics industries.
Specifications:
Range:10-99.99%/50-99.99%/90-99.99%/97%-99.99%O2;auto-ranging
Accuracy:±0.5% of FS range, ±0.1% of 90-99.99%
Repeatability:Cv≤0.5%
Preheating time:300s
Sample gas flow speed:150~300ml/min
Stability:zero drift ≤0.5% of FS/7d , span drift ≤0.5% of FS/7d
Response time:90% of FS reading in 15 seconds
Sensitivity:0.01% O2
Power supply:85-265 VAC, 50/60Hz, power loss≤6w
Signal outputs:4-20mA or 0-5V DC isolated
Contact capacity:125VAC 0.3A, 110VDC 0.3A, 30VDC 1A
Expected sensor life:3 years (in normal condition)
Installing dimension:W×H×D=92mm*92mm*110mm