Class 0.05 120A 560V Portable Three Phase Power Calibrator

Min.Order: 1
Product origin: Beijing, China
Infringement complaint: complaintComplaint
US$ 25800

Description

GF302D1 class 0.05 120A 560V portable three phase power calibrator

The GF302D1 three phase portable power calibrator consists of an integrated three phase current and voltage source(up to 500V/120A or 500V/20A) and built-in three-phase electronic reference standard of accuracy class 0.05%. Characteristic features of the GF302D1 are its wide measuring range, high accuracy and high tolerance to unwanted external influences. The equipment offers high functionality combined with an excellent menu guided operation via built-in keyboards and colored 7" touch LCD-display.
 

FEATURES

  • Accuracy class 0.05
  • 0-20A/0-500V, 0-120A/0-500V
  • Start testing and creep testing
  • Reference standard and power source integrated
  • Test by automatic or manual
  • 7 inch TFT touch screen
  • Weight light 15Kg
  • Recorder 500 sets energy meter data
  • Overload, short circuit, open circuit protection

PARAMETERS

Electrical parameters 
Accuracy0.05%, 0.1%
Power SupplyOne Phase AC 100-265V, frequency 50/60Hz.
AC Voltage Output 
Range(U1,U2,U3)57.7V, 100V, 220V, 380V
or 69.3V, 120V, 240V, 480V( optional)
Adjustment range(0-120)%RG(1)
Adjustment fineness0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability0.01%/120s
Distortion0.3% (Non-capacitive load)
Output loadeach phase 30VA
Measuring accuracy0.05%RG
AC Current Output 
Range(I1,I2,I3)200mA, 1A, 5A, 20A, 100A(optional)
Adjustment range(0-120)%RG
Adjustment fineness0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability<0.01%/120s
Distortion≤0.3% (Non-capacitive load)
Output load30VA
Accuracy0.05%RG
Power Output  
Active power output stability<0.01%RG/120s
Reactive power output stability<0.02%RG/120s
Active power measuring accuracy 0.05%RG
Reactive power measuring accuracy0.1%RG
Phase Output  
Output adjustment range0°-359.999°
Output adjustment fineness10, 1, 0.1, 0.01 as optional.
Resolution0.01°
Accuracy0.03°
Power Factor 
Adjustment range-1 ~ 0 ~ 1
Resolution0.0001
Measurement accuracy0. 0005
Frequency Output  
Adjustment range40Hz-70Hz
Output adjustment fineness5Hz, 1Hz, 0.1Hz, 0.01Hz as optional.
Resolution0.001Hz
Accuracy0.005Hz
Voltage /Current/Harmonic Setting 
Harmonic number2-51times
Harmonic content0-40%
Harmonic phase0-359.99
Harmonic setting accuracy(10%±0.1%)RD(2)
Power Energy Measurement Error 
Active power energy0.05%RG
Reactive power energy0.1%RG
Power Pulse Output  
Power pulse typeactive pulse, reactive pulse
Active power pulse output 5V,  10mA
Power Pulse Input 
Energy pulse typesupport active and reactive pulse, the highest frequency power pulse input is 180K.
Mechanical parameters 
Dimensions (W×D×H) (mm)495x390x195
Weight (kg)15
Environmental conditions
Ambient temperature-10°C to +50°C
Relative humidity35%-85%
(1) RG means range, the same as below;
(2) RD means the setted harmonic content, harmonic can be a single output, also multiple output.

SELECTION GUIDE

NO.AccuracyVoltage rangeCurrent RangeWeight
302D1120010.10%0-500V0-120A22KG
302D11200050.05%0-500V0-120A22KG
302D112010.10%0-500V0-12A15KG
302D1120050.05%0-500V0-12A15KG
302D124010.10%0-500V0-24A16KG
302D1240050.05%0-500V0-24A16KG

 

Product Tag:
Related categories:
Scroll to Top