Xmte-7000 Cj Intellgence Industrial Digital Temperature Control Instrument

Min.Order: 1
Product origin: Ningbo, Zhejiang, China
Infringement complaint: complaintComplaint
US$ 9.68 ~ 25

Description
Temperature controller
Intelligence dual row 4-LED diSplay
Operated with 4-key
Control method: On/off, automatic regulation

XMT*7000 series temperature controller are intelligence dual row 4-LED display for displaying the measured value and set value respectively. The temperature meter are operated with 4-keys, allowing an easy inputting. The available control methods include on/off, 2-on/off, PID and automatic regulating and setting controls.

I.Product characteristic
The core of the product adopts the up-to-date microrocessor chip.
Red and green double-bank nixie tube display the measured value and setting value.
Easy operation in the four/three keys, & fast setting in the parameter.
Control in high precision's PID intelligent and two or three bit location check program.
Upper-bank display the measured value, & bottom-bank display the setting value under normal working conditions.
 
II.Primary technical standard
1.Input: Thermocouple: K,E,J,S
Thermal resistance: PT100 , CU50
2. Range: K(0~400ºC,0~1300ºC),E(0~400ºC,0~800ºC),J(0~1000ºC),
        S(0~1600ºC),PT100(-100.0~200.0ºC,0~600ºC),CU50(-50.0~150.0ºC)
3.Measure error: ±0.5%F.S±1byte
4.Silicon control trigger signal(over zero): Range≥3V, Width≥40us
5.The output contact potential of the relay: impedance load AC220V  5A
6.Input power: AC85~242V   50/60Hz
7.Environment:  Temperature: 0 to 50ºC,  Humidity: ≤85%RH
8.Size: XMT:160×80×125mm  hole: 152×76;  XMTA:96×96×85mm  hole: 92×92; 
   XMTE:48×96×85mm   hole: 44×92;  XMTF:96×48×85mm   hole: 92×44;
   XMTD:72×72×85mm   hole: 68×68;  XMTG:48×48×110mm   hole: 44×44; 

Name and functions of the sections(consult)


1)PV display
Indicates the process variable (PV) with a red LED.
(2)SV display
Indicates the setting value (SV) with a green LED.
(3)AT indicator
When auto tuning function is ON, a green LED lights.
(4)ALM1 indicator
When ALM1 output is ON, a red LED lights.
(5)ALM2 indicator
When ALM2 output is ON, a red LED lights.
(6)OUT indicator
When OUT is ON, a green LED lights.
(7)Mode key (SET)
Switches the setting mode and registers the setting value and selected value.
(Setting value and selected value are registered by pressing the mode key.)
(8)Data shift key (<)
(9)Decrease key (∨)
Decreases numeric value of the setting value
(10)rease key (∧)
Increases numeric value of the setting value.

Display Status(consult) 

Connection figure(consult) 
Setup flow chart
CodeDescriptionSetting range InstructionRemarks
SPSetting control pointWhole rangeºC or 1 defined unit_
AL1Alarm 1Whole rangeºC or 1 defined unit 
AL2Alarm 2Whole rangeºC or 1 defined unit 
SCMeasurement update-20.0 to 20.0Measuring value can be modified through
increasing or decreasing this data.
Note: It may be cause inaccurate racy of measuring value when you use this function . Please use the function carefully according to your situation.
0
PProportional band0 to 9999When the P↑,the proportion and differential function↑; if the P↓,the proportion and differential function↓. When P=0,the meter is ON/OFF control100
IIntegration time0 to 3000sIt's mainly used to adjust the static difference. To increase it, the static difference will be reduced, but when it is too high, the static difference will drift instability.500
dDifferential time0 to 2000sWhen the I↓,the calculus function↑;
I↑the calculus function↓.
When I=0, no calculus function, it is PD adjustment instrument
100
tControl period1 to 120sWhen the d↓,the proportion and calculus function↑; if d↑,the proportion and calculus function↓,but the differential function↑.
When d≤t, it has no differential function
20
HyDeadband0.1to 50.0ON/OFF control only1.0
AtAuto-man0 to 10-     Close auto-man function
1-     Open auto-man function
0
LockKey lock0 to 10-     All the parameter can rework
1-     Only SP value can rework
>1 All the parameter can not rework
0