Description
semiconductor voltage protection fuses
material: soda lime glass, borosilicate glass, ceramic glass,
Precision fuse glass tube
Small diameter thin-walled precision glass tubing which, by design, exhibits capillary action. Capillary action is the movement of a liquid into a tube based on its surface tension. Glass Micro Bore Tube Features
Capillary glass tubing from molten glass drawn it into long lengths. These are then cut to a specific length and the ends of the tubes are flame polished. Many times the tubes are marked with a color coded fill line to designate volume calibration for applications like disposable glass micropipettes.
In the case of blood collection tubes (called hematocrit tubes), these are processed in the same manner; However, some are coated with heparin (an anticoagulant) so that blood does not clot when drawn.
Glass Capillary Tube Features
Precision ID Tolerance to ± 0.0001
ID Sizes from 0.001 to 0.020
OD Range to 0.125
Precision Volumetric Marking Measures
Chemically and physically unaffected by sterilization
Inert and non-reactive with most drugs, bodily fluids, or gases
Safe for direct human contact
Glass Capillary Tube Applications
Micro Dispensing medication delivery
Clinical testing or sample collection
Hematocrit Glass Capillary Tubes for blood collection
Disposable "Marked" Glass Micropipettes
Micropipette for precise predetermined volume dispensing (aliquot)
Capillary spotters for depositing small amounts of a sample onto a TLC (thin layer chromatography) plate
SN | OD(mm) | ID(mm) | Length(mm) |
1 | 2.45±0.1 | 0.8±0.05 | 40 |
2 | 2.50±0.02 | 1.68±0.01 | 70 |
3 | 3.0±0.1 | 1.0±0.005 | 110 |
4 | 4.0±0.02 | 2.0±0.02 | 100 |
5 | 4.0±0.05 | 3.0±0.01 | 20 |
6 | 5.0±0.1 | 2.7±0.02 | 120 |
7 | 5.0±0.1 | 3.0±0.01 | 30 |
8 | 5.0±0.2 | 0.2±0.01 | 15 |
9 | 6.0±0.05 | 4.0±0.005 | 68 |
10 | 8.0±0.2 | 2.5±0.05 | 30 |
11 | 9.1±0.1 | 4.605±0.01 | 90 |
12 | 9.6±0.3 | 6.84±0.03 | 60 ± 0.1 |
13 | 12.3±0.3 | 9.2±0.02 | 61.5±0.3 |