Dixell Controller Xr20cx Prime Cx Refrigeration Controllers

Min.Order: 10
Product origin: Shenzhen, Guangdong, China
Infringement complaint: complaintComplaint
US$ -1

Description
Dixell Controller Xr20cx Prime CX Refrigeration Controllers

DIGITAL CONTROLLER WITH "OFF CYCLE" DEFROST
Generals
Power supply: 110, 230Vac
Probe inputs
Thermostat: NTC
Digital inputs
Alarm, start defrost, AUX, door switch, pressure switch: Configurable
Relay outputs
Compressor: 8A, 20A optional
Other
Hot Key: Present
Buzzer: Optional (available only with 8A compr. Relay)
 
The new PRIME series in CX format, is an innovative range of products that Dixell has introduced to the market for both heating and L.T., N.T. refrigeration. The CX family (32x74mm) has new functions plus an innovative and attractive design. The revolutionary introduction of 6 keys allows the user direct access to all main functions rapidly and intuitively, while the display with illuminated icons allows an instant view of the machine's status. All the instruments in CX format incorporate the latest know how and technology, both in software and hardware to ensure the highest standards of performance. 
  • Easy and intuitive installation
  • 9 - 40Vdc power supply for refrigerated trucks (for models with 8A compressor)
  • Energy saving cycles triggered via a digital input; for example, it is possible to work at a set point that is different from the normal one in order to, for instance, accumulate cold when electric power is cheaper
  • Continuous cycle with dedicated set; it allows the machine to work during rapid cooling cycles to achieve the right product temperature
  • Regulation stop by auxiliary probe (beer dispenser applications); it is possible to supervise the tube temperature, stopping the compressor when the temperature becomes too low, and restarting when the correct values have been restored
  • Regulation re-start with door switch alarm
  • Max and Min temperature or HACCP function
  • Digital input configurable as probe
  • Virtual probe for air on / air off application; used in multideck applications where it is important to regulate temperature using the average of 2 temperatures
  • Dual thermostat function; is available, on demand, in applications such as white or red wine rooms where it is necessary to maintain 2 different temperatures
  • Condenser temperature management to prevent critical situations in the system
  • TTL serial connection for monitoring systems (using XJ485CX)
  • Connection for remote display X-REP (excludes TTL)
 

Thermostat and Controllers with  " OFF CYCLE"  DEFROST  for Normal, Medium  and  Low Temperature

XR10CX  Thermostat with heating or cooling action.
XR20CX Controller for NT with "off cycle" defrost.
XR30CX Controller for NT with "off cycle" defrost and additional configurable relay.
XR35CX Controller for NT with "off cycle" defrost and additional configurable relay and RS485.
XR36CX 2 set point controller for NT with "off cycle" defrost; created for applications where is necessary to maintain 
2 different temperature such as white/red wine room

     
Controllers  for  Normal, Medium  and  Low Temperature

XR40CXDigital controller for MT  and LT with electrical or hot gas  defrost.
XR50CX  Controller for MT  and LT with electrical or hot gas  defrost and auxiliary relay.
XR56CX2 set point controller for MT and LT with electrical or hot gas defrost and auxiliary relay; created for applications where is necessary to maintain 2 different temperature such as white/red wine roo


Controllers  for Medium  and  Low Temperature

XR60CX 

Controller for MT and LT ventilated applications with dual humidity function on demand, this allows the user to activate or deactivate ventilation directly through keys, in order to regulate the humidity depending on the kind of product (ideal for pastry applications)

XR64CX   Controller for MT and LT ventilated applications with twin evaporators; normal regulation restarts only when both evaporators have reached defrost termination temperature
XR70CX Controller for MT and LT ventilated applications, with auxiliary relay and with dual humidity function on demand, this allows the user to activate or deactivate ventilation directly through keys, in order to regulate the humidity depending on the kind of product (ideal for pastry applications)
XR71CXController for MT and LT ventilated applications with anti-sweat heater management; created for applications that utilize heating elements such as anti-mist or anti-freeze heaters on doors (heater elements can be actived by pushing a key or through a dedicated probe)
XR72CX Controller for MT and LT ventilated applications with dual compressor management
XR75CXController for MT and LT ventilated applications with auxiliary relay, dual humidity function and RS485
XR77CXController for MT and LT ventilated applications with Real time clock with RS485

 

 

 
FEATURESXR10CXXR20CXXR30CXXR35CXXR36CX
Power supply12, 24Vac/dc,c
24, 110, 230Vac
9 ÷40Vdc
12, 24Vac/dc,
24, 110, 230Vac
9 ÷40Vdc
12, 24Vac/dc,
24, 110, 230Vac
9 ÷40Vdc
 24, 110, 
230Vac
12, 24Vac/dc,
24, 110, 230Vac
9 ÷40Vdc
Display : number digits± 3 d.p.± 3 d.p.± 3 d.p.± 3 d.p.± 3 d.p.
Probe inputs
Thermostat NTC / PTCNTC / PTCNTC / PTCNTC / Pt1000 NTC / PTC
Thermostat 2---- NTC / PTC
Defrost---NTC / Pt1000-
Condenser NTC/PTC 
on hot key
NTC/PTC 
on hot key
NTC/PTC 
on hot key
 NTC / Pt1000 NTC/PTC 
on hot key
Digital inputs
Alarm,start defrost, AUX, door switch, pressure switch, probe ConfigurableConfigurableConfigurable Configurable Configurable
Alarm,start defrost, AUX, 
door switch, pressure switch
--- Configurable-
Relay outputs
Compressor8A/20A8A/20A8A/20A8A/16A8A/20A
Compressor 2, Thermostat 2----8A
Defrost-----
Fan-----
Light or Alarm--8A8A-
Anti - sweat-----
Other
Hot key / Programming Tool Kit outputPresentPresentPresentPresentPresent
Remote display outputX - REP optionX - REP optionX - REP optionX - REP optionX - REP option
Serial outputTTLTTLTTLTTL/RS485TTL
Buzzeravailable only with  compressor =  8A
Real time clock-- option option-
 
FEATURESXR40CXXR50CXXR56CX
Power supply12, 24Vac/dc,
24, 110Vac, 230Vac
9 - 40Vdc
12, 24Vac/dc,
24, 110Vac, 230Vac
9 - 40Vdc
24, 110Vac, 230Vac12, 24Vac/dc,
24, 110Vac, 230Vac
9 - 40Vdc
24, 110Vac, 230Vac
Display : number digits± 3 d.p.± 3 d.p.± 3 d.p.± 3 d.p.± 3 d.p.
Probe inputs
ThermostatNTC / PTCNTC / PTCNTC / PTCNTC / PTCNTC / PTC
Thermostat 2---NTC / PTCNTC / PTC
DefrostNTC / PTCNTC / PTCNTC / PTC--
CondenserNTC / PTC  on hot key
 Digital input
Alarm,start defrost, AUX, door switch, pressure switch, probeConfigurableConfigurableConfigurableConfigurableConfigurable
Alarm,start defrost, AUX, 
door switch, pressure switch
-----
Relay outputs
Compressor 8A/20A8A/16A 20A 8A/16A 20A
Compressor 2, Thermostat 2--- 8A 8A
Defrost 8A 8A 8A--
Fan-----
Light or Alarm- 8A 5A 8A5A
Anti - sweat-----
Other
Hot key / Programming Tool Kit outputPresentPresentPresentPresentPresent
Remote display outputX - REP optionX - REP optionX - REP optionX - REP optionX - REP option
Serial outputTTLTTLTTLTTLTTL
Buzzeravailable only with  compressor =  8A
Real time clock-----
 
 
FEATURES XR60CXXR64CX XR70CX
Power supply12, 24Vac/dc,
24,110Vac,230Vac
9 - 40Vdc
24,110Vac, 230Vac24,110Vac, 230Vac12Vac/dc 24,110Vac, 230Vac12Vac/dc 
Display : number digits± 3 d.p.± 3 d.p.± 3 d.p.± 3 d.p.± 3 d.p.± 3 d.p.
Probe inputs
ThermostatNTC / PTCNTC / PTCNTC / PTCNTC / PTCNTC / PTCNTC / PTC
Thermostat 2------
DefrostNTC / PTCNTC / PTCNTC / PTCNTC / PTCNTC / PTCNTC / PTC
Defrost 2--NTC / PTCNTC / PTC--
CondenserNTC / PTC  on hot key
Digital input
Alarm,start defrost, AUX, 
door switch, pressure switch, probe
ConfigurableConfigurableConfigurableConfigurableConfigurableConfigurable
Alarm,start defrost, AUX, 
door switch, pressure switch
------
Relay outputs
Compressor 8A/16A  20A 8A/16A 16A8A/16A  16A
Compressor 2,------
Thermostat 2------
Defrost8A8A8A16A8A16A
Defrost 2--8A16A--
Fan8A5A5A16A5A16A
Light or Alarm----8A16A
Anti - sweat------
Other
Hot key / Programming Tool Kit outputPresentPresentPresentPresentPresentPresent
Remote display outputX - REP option
Serial output TTLTTLTTLTTLTTLTTL
Buzzeravailable only with  compressor =  8A
Real time clock----optionoption
 
FEATURES XR71CXXR72CX XR75CX XR77CX
Power supply24, 110Vac, 
230Vac
 12Vac/dc  24, 110Vac, 
230Vac
 12Vac/dc  24, 110Vac, 
230Vac
 230Vac
Display : number digits± 3 d.p.± 3 d.p.± 3 d.p.± 3 d.p.± 3 d.p.± 3 d.p.
Probe inputs
Thermostat NTC / PTCNTC / PTC  NTC / PTC NTC / PTCNTC / Pt1000NTC / PTC
Thermostat 2------
DefrostNTC / PTCNTC / PTCNTC / PTCNTC / PTCNTC / Pt1000NTC / PTC
Defrost 2------
CondenserNTC / PTC  on hot keyNTC / Pt1000NTC / PTC
Digital input
Alarm,start defrost, AUX, 
door switch, pressure switch, probe
 Configurable Configurable Configurable ConfigurableConfigurableConfigurable
Alarm,start defrost, AUX, 
door switch, pressure switch
----ConfigurableConfigurable
Relay outputs
Compressor8A/16A 16A8A/16A16A8A/16A16A
Compressor 2, Thermostat 2--8A16A--
Defrost8A16A8A16A8A8A
Defrost 2------
Fan5A16A5A16A5A5A
Light or Alarm----8A8A
Anti - sweat8A16A----
Other
Hot key / Programming Tool Kit outputPresentPresentPresentPresentPresentPresent
Remote display outputX - REP option
Serial outputTTLTTLTTLTTLRS485RS485
Buzzeravailable only with  compressor =  8A
Real time clock----option Present
 
HOW TO ORDER
PRIME CX
XR--CX-ABCDE
 
ABCDE
Power SupplyInputs-BuzzerX-REP
(excludes TTL output)
RS485  output- Measurement      unitRTC-Compressor  outputConnection
0 = 12Vac/dcP = PTC0NoNoNoC°CNo08AScrew
= 12Vac/dcN = NTC1YesNoNoF°FNo120AScrew
2 = 24VdcS =Pt1000
  only for XR35/75CX
2NoYesNoH
 
°C 
heating only for  XR10CX
No316AScrew
3 = 9 ÷40Vdc3YesYesNo68AFaston
4 = 110Vac-
-
-
-
4NoNoYesL°F 
heating only for  XR10CX
No720AFaston
5 = 230Vac5YesNoYes816AFaston
-
-
6NoYesYesI°CYes-
-
-
-
-
-
7YesYesYesM°FYes
 


Product Tag:
Related categories:
Scroll to Top