High Furnace for Burning Biomass Wood Sawdust Rated Steam and Hot Water Boiler

Min.Order: 1
Product origin: Qingdao, Shandong, China
Infringement complaint: complaintComplaint
US$ 60000 ~ 80000

Description
High Furnace for Burning Biomass Wood Sawdust Rated Steam and Hot Water Boiler

1.The boiler shall adopt double drum,monolayer arrangement,compact structure,as well as large heating surfaces which aremore 10% than those of same kinds of products,featuring the following advantages such as sufficient output,safe and reliableoperation,short construction period,low installation cost ect.
2.The design of cyclone reburning chamber in furnace resulted in the decrease of dust contained in the flue gas.At the same time,incandescent carbon black particles shall burn further,enhancing the boiler thermal efficiency,decreasing gas blackness,as a result,the gas emission concentration shall meet the requirements of grade A environmental protection area.
3.The grate shall employ the technology patent of small roller structure,boundary grate and so on,improving the operation reliability of the boiler.
4.Since the adoption of technology patent for the sealed wind chamber and bilateral grate air register,and the application of machining cone seal structure to grate adjusting air eauipment,the sensitivity of the grate shall be improved.
Boiler main body will be loaded on the 20' or 40' FR(flat rack) containers with weather cloth,boiler accessories will be packed with plywood boxes and loaded in the 20-feet or 40-feet GP(Standard) containers.

Weclome to Qingdao,we will talk more details,check our workshop and running boilers.


Item
Boiler type
Model
SZL6
-1.25/
1.6/2.5
-AII
SZL8
-1.25/
1.6/2.5
-AII
SZL10
-1.25/
1.6/2.5
-AII
SZL10
-1.25/
1.6/2.5
-AII
SZL15
-1.25/
1.6/2.5
-AII
SZL20
-1.25/
1.6/2.5
-AII
SZL25
-1.25/
1.6/2.5
-AII
Evaporation capacity
T/h
6
8
10
12
15
20
25
Working pressure
Mpa
1.25/
1.6/
2.5
1.25/
1.6/
2.5
1.25/
1.6/
2.5
1.25/
1.6/
2.5
1.25/
1.6/
2.5
1.25/
1.6/
2.5
1.25/
1.6/
2.5
Steam temperature
ºC
194/
204/
226
194/
204/226
194/
204/226
194/
204/
226
194/
204/
226
194/
204/
226
194/
204/
226
Inlet water temperature
ºC
20
20
20
20
105
105
105
Heating efficiency
%
≥78
≥78
≥80
≥80
≥81
≥81
≥81
Area of boiler heating
surface

147.8
175
220
388
443
578
626
Area of stoker

7.6
9.6
11.72
14.2
17.2
22.6
26.3
Coal available

II type bituminous,low heat capability:17700-21000KJ/kg
Water pump
Model

2GC-5×6
2½GC-6×6
DG12×7
DG15-35×5
DG15-35×5
DG25-35×5
DG46×30
Motor
power
Kw
15/18.5
15/18.5
18.5/22
22/30
22/30
30/37
37/45
Blast fan
Model

G6-41-13
NO7.1A
G6-41-13
NO8.5A
G6-41-13
NO8.5A
G6-41-13
NO8.5A
G6-41-13
NO8.5A
G6-73-11
NO11D
G4-68-10D
Ventilation
M³/h
5349-10354
9369-18137
9369-18137
9369-18137
9369-18137
36100
33173-
58856
Wind
pressure
Pa
1697-2270
2535-3391
2535-3391
2535-3391
2535-3391
2730
2313-3401
Motor
power
Kw
7.5
18.5
18.5
18.5
18.5
37
45
Induced
draft fan
Model

Y6-41-13
NO10C
Y6-41-13
NO11.2D
Y6-41-13
NO11.2D
Y6-41-13
NO11.2D
Y8-39-13
NO10D
GY20-15
Y4-68
NO12.5D
Ventilation
M³/h
32144-
16604
41773-
21578
41773-
21578
41773-
21578
4500
73308
60611-
110772
Wind
pressure
Pa
2575-3444
2764-3697
2764-3697
2764-3697
3205
3515
3765-2589
Motor
Power
Kw
37
45
45
55
90
110
132
Maximum size for
shipment
M
7.83×3.34
×3.46
8.82×3.34
×3.46
8.0×3.5
×2.7
7.2×3.3
×3.6
8.0×3.3 ×3.6
10.6×3.35
×3.69
10.8×4.46
×3.76
Maximum weight for
shipment
T
48/51/53
56/58/60
96/97/98
102/103
/104
107/108
/109
152/154
/156
210/212
/214







Scroll to Top