Mode Code | Descriptions |
0 | Query mode of historical loop data |
1 | Capacity discharging test |
2 | Typical charge |
3 | Loop mode 3: Starting with discharge and ending with charge Max. loop number: 50 times |
4 | Loop mode 4: Starting with charge and ending with charge Max. loop number: 50 times |
5 | Loop mode 5: Starting with discharge and ending with discharge Max. loop number: 50 times |
6 | Loop mode 6: Starting with charge and ending with discharge Max. loop number: 50 times |
Model No.: SF200-5/6 | ||||
Items | Parameter | |||
Input Voltage: | AC 220 V± 10% 50 Hz / 60 Hz | |||
Input Power: | No-load: | SF200-5 | SF200-6 | |
70W | 80W | |||
Full-load: | SF200-5 | SF200-6 | ||
1000W | 1200W | |||
Applicable Battery Types: | 6 V, 12 V, 16 V, 18V Storage Batteries | |||
Functions: | Charge | |||
Discharge | ||||
Auto cycle charge and discharge | ||||
Data record and inquire | ||||
Voltage | Max. Charge Voltage: | 23 V | ||
Min. Charge Voltage: | 7V | |||
Amplitude Of Adjustment: | 0.1 V stepping | |||
Charge Voltage Tolerance: | ± 0.5 V | |||
Max. Discharge Cut-off Voltage: | 20 V | |||
Min. Discharge Cut-off Voltage: | 2 V | |||
Amplitude Of Adjustment: | 0.1 V stepping | |||
Discharge Voltage Tolerance: | ± 0.03 V | |||
Current | Charge Current: | 0.5 A - 10 A adjustable | ||
Amplitude Of Adjustment: | 0.1 A stepping | |||
Charge Current Tolerance: | ± 0.1 A | |||
Discharge Current: | 0.5 A - 20 A adjustable | |||
Amplitude Of Adjustment: | 0.1 A stepping | |||
Discharge Current Tolerance: | ± 0.03 A | |||
Charge | Charge Mode: | Constant current & voltage charge | ||
Cut-off Conditions: | When reaching high constant voltage, the system will automatically switch to trickle charge after charging for 3.5 hours or the charging current is less than 0.3A | |||
Discharge | Discharge Mode: | Constant current discharge | ||
Cut-off Conditions: | Voltage | |||
Cycle | Max. Cycle Index: | 50 Times | ||
Protection: | Power-down protection | |||
Reverse connection protection | ||||
Over-temperature protection | ||||
Over-voltage protection | ||||
Short-circuit protection | ||||
IP Grade | IP20 | |||
Channel Control Mode | Independent control | |||
High Voltage Insulation Between Channels | AC1000V/2min Normal | |||
Data Display | LCD | |||
Operation Method | Panel | |||
Voltage & Current Test Sampling | Four-core wires connection | |||
Noise | < 76 dB | |||
Upper Computer Communication | None | |||
Communication Port | None | |||
Equipment Work Ambient Conditions | ||||
Operation Ambient Temperature | 0 ºC - 40 ºC | |||
Storage Temperature | -10 ºC - 50 ºC | |||
Operation Ambient Humidity | ≤ 70 % RH (No condensation) | |||
Storage Ambient Humidity | ≤ 80 % RH (No condensation) |
Model No.: | SF200-5 | SF200-6 |
Product Size(L*W*H): | 65.5*40*17 cm | 78*40*17 cm |
Pcs/Ctn: | 1 pcs/ctn | 1 pcs/ctn |
Package Size(L*W*H): | 77.5*49*30 cm | 91.5*49*30 cm |
G.W.: | 17.30 kgs | 20.30 kgs |
N.W.: | 15.30 kgs | 18.30 kgs |