OPERATING CONDITIONS:
Frame size | H112-355 |
Power | 0.55-90KW |
Voltage as follows | 1)Rated Voltage for Controller: 220V; 2)Rated Voltage for the motor:380V(three phase) 220V(single phase) |
Rated Frequency | 50 Hz |
Poles | 4A,4B |
Speed | 1250-125, 1320-132, 1320-440 ,1320-600 |
Ambient temperature | -15°C < θ < 40°C |
Model of CONEECTION | Y-Connection for 3 KW motor or less while Delta-Connection for 4 KW motor or more |
Duty | continuous (S1) |
Insulation Class | B/F |
Protection Class | IP21 |
Frame material | Cast iron body |
Cooling Method | IC411 Standards |
PERFORMANCE DATA :
TYPE | Rated Power | Rated Torque | speed range |
KW | N.m | R/min | |
YCT112-4A | 0.55 | 3.6 | 1230~125 |
YCT112-4B | 0.75 | 4.9 | 1230~125 |
YCT132-4A | 1.1 | 7.1 | 1230~125 |
YCT132-4B | 1.5 | 9.7 | 1230~125 |
YCT160-4A | 2.2 | 14.1 | 1250~125 |
YCT160-4B | 3 | 19.2 | 1250~125 |
YCT180-4A | 4 | 25.2 | 1250~125 |
YCT200-4A | 5.5 | 36.1 | 1250~125 |
YCT200-4B | 7.5 | 47.7 | 1250~125 |
YCT225-4A | 11 | 69 | 1250~125 |
YCT225-4B | 15 | 94 | 1250~125 |
YCT250-4A | 18.5 | 110 | 1320~132 |
YCT250-4B | 22 | 137 | 1320~132 |
YCT280-4A | 30 | 189 | 1320~132 |
YCT315-4A | 37 | 232 | 1320~132 |
YCT315-4B | 45 | 282 | 1320~132 |
YCT355-4A | 55 | 344 | 1340~440 |
YCT355-4B | 75 | 469 | 1340~440 |
YCT355-4C | 90 | 564 | 1340~600 |