All of the Sentek's SD119-G series detectors meet the requirements of UL 268 and EN 54-7/5 for use in fire alarm signaling systems. They are intended for use in 2-wire/4-wire Class A or B supervised zone circuits. The SD119 series detectors are subject to panel compatibility limits and compliance with corresponding NFPA 72E standards, local codes, and ordinances. 

We also have 12v,24v models with UL certificate
SD119-2:   https://cnsentek.en.made-in-china.com/product/yqsxKvAUEZRp/China-Conventional-Photoelectric-Electric-Smoke-Alarm-with-UL-Certification.html
SD119-4:   https://cnsentek.en.made-in-china.com/product/FSnxvkqbLlUZ/China-4-Wire-Conventional-Fire-Smoke-Heat-Alarm-with-Relay-Output.html

Specification:

Smoke Sensitivity:0.08~0.30db/m(EN standard) or 0.98~4%/FT Obsuration(UL standard)
Ceiling Spacing:50 foot rating for heat sensor
Reset Voltage:less than 5 volt
Reset Time:less than 1 second
Alarm Indicator:LED continuously emitting red light
Remote Output:3.0~3.7VDC when in series a LED & 100 Ω resistor
OperatingTemperature:-20°C to 80°C
Storage Temperature:-30°C to 80°C
Humidity:0 to 95% RH, no condensation or icing
Alarm Contact:(for 4-wire)NO or NC Operation, Form A: 1.0A@30VDC/0.5A@125VAC
Dimensions:100mm (dia) x 46mm (ht) with base
Weight:130g/set with base

 2 Wire 4 Wire Smoke Detector Sensor for Home Security System 




Product Features: 

*2 or 4 wire models
*Wide voltage range and stable output
*Advanced detection and discrimination algorithms 
*Easy installation and maintenance
*Sleek low-profile housing design
*Durable sensor head, no need for replacement 
*SMD circuit board design: satisfactory quality and reliability guaranteed
*N/C and N/O relay output  
*Auto reset function for security systems (4 wire optional ) Sensor base option:standard and Schottky Diode
*Five-year warranty

Order Information:

SD119-G-2:                  2 wire photoelectric smoke alarm

SD119-G-2-LED:          2 wire photoelectric smoke alarm with remote LED output

SD119-G-2H:                2 wire photoelectric smoke and heat alarm

SD119-G-2H-LED:        2 wire photoelectric smoke and heat alarm with remote LED output

SD119-G-4:                  4 wire photoelectric smoke alarm

SD119-G-4B:               4 wire photoelectric smoke alarm with Buzzer

SD119-G-4AR:              4 wire photoelectric smoke alarm with auto-reset function

SD119-G-4ARB:           4 wire photoelectric smoke alarm with auto-reset function and Buzzer

SD119-G-4H:              4 wire photoelectric smoke and heat alarm 

SD119-G-4HB:             4 wire photoelectric smoke and heat alarm with Buzzer

SD119-G-4HAR:           4 wire photoelectric smoke and heat alarm with auto-reset function

Model

2/4

Wire

Thermal

Voltage DC

(Min./MAX.)

Standby Current

(Max.)

Alarm Current

(12/24V)

Surge Current

(Max.)

Start-Up Time

(Max.)

Supervision Time(Max.)Alarm ContactCertified
SD119-G-22 10~36V65µA30~40mA150µA20S3Sec.-P/N852001 
SD119-G-2L2 10~36V65µA30~40mA150µA20S3Sec.-P/N852001 
SD119-G-2H257°C10~36V65µA30~40mA150µA20S3Sec.-P/N852001 
SD119-G-2HL257°C10~36V65µA30~40mA150µA20S3Sec.-P/N852001 
SD119-G-44 10~60V65µA25mA150μA20S3Sec.Form AP/N852001 
SD119-G-4H457°C10~60V65µA25mA150μA20S3Sec.Form AP/N852001 
SD119-G-4AR4 10~60V65µA25mA150μA20S3Sec.

Form A/

Auto Reset

P/N852001 
SD119-G-4HAR457°C 10~60V56µA245mA150μA20S3Sec.

Form A/

Auto Reset

P/N852001 
SD119-G-4B4 10~60V65µA30mA150μA20S3Sec.Form AP/N852001 
SD119-G-4BAR4 10~60V65µA30mA150μA20S3Sec.Form A/Auto ResetP/N852001 
SD119-G-4HB457°C10~60V65µA30mA150A20S3Sec.

Form A

 

P/N852001 
SD119-G-4HARB457°C20~60V65μA30mA150μA20S3Sec.

Form A/Auto Reset